Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
3,669
datasets available to search
ShareScore release 0.9.0
Dataset results
3,669 results for “Lasers”
Plot-level wood-leaf separation for terrestrial laser scanning point clouds
Open the record for dataset details and reuse information.
Data for: UK redwoods terrestrial laser scanner point clouds
Open the record for dataset details and reuse information.
Thermal pressure in the laser heated diamond anvil cell: a quantitative study and implications for the density vs. mineralogy correlation of the mantle
Open the record for dataset details and reuse information.
Measurement of Absolute Retinal Blood Flow Using a Laser Doppler Velocimeter Combined with Adaptive Optics
<p><strong>Data set of measurements related to the following:</strong></p> <p><strong>Purpose: </strong>Development and validation of an absolute laser Doppler velocimeter (LDV) based on an adaptive optical fundus camera which provides simultaneously high definition images of the fundus vessels and absolute maximal red blood cells (RBCs) velocity in order to calculate the absolute retinal blood flow.</p> <p><strong>Methods: </strong>This new absolute laser Doppler velocimeter is combined with the adaptive optics fundus camera (rtx1, Imagine Eyes©,Orsay, France) outside its optical wavefront correction path. A 4 seconds recording includes 40 images, each synchronized with two Doppler shift power spectra. Image analysis provides the vessel diameter close to the probing beam and the velocity of the RBCs in the vessels are extracted from the Doppler spectral analysis. Combination of those values gives an average of the absolute retinal blood flow. An in vitro experiment consisting of latex microspheres flowing in water through a glass-capillary to simulate a blood vessel and in vivo measurements on six healthy human retinal venous junctions were done to assess the device.</p> <p><strong>Results: </strong>In the in vitro experiment, the calculated flow varied between 1.75 μl/min and 25.9 μl/min and was highly correlated (r2 = 0.995) with the imposed flow by a syringe pump. In the in vivo experiment, the error between the flow in the parent vessel and the sum of the flow in the daughter vessels was between −25% and 17% (mean±sd −2 ± 17%). Retinal blood flow in the main temporal retinal veins of healthy subjects varied between 1.3 μL/min and 28.7 μL/min</p> <p><strong>Conclusion: </strong>This adaptive optics LDV prototype (aoLDV) allows the measurement of absolute retinal blood flow derived from the retinal vessel diameter and the maximum RBCs velocity in that vessel.</p>
Dataset in the manscript titiled Magnetic field effect on plume dynamics and optical emission of laser-produced tungsten plasma in vacuum
<p>This is the data in the manuscript titiled "Magnetic field effect on plume dynamics and optical emission of laser-produced tungsten plasma in vacuum"submitted to POP </p>
Model-independent inference of laser intensity
<p>Data required to reproduce the figures and analysis given in T. G. Blackburn, E. Gerstmayr, S. P. D. Mangles and M. Marklund, "Model-independent inference of laser intensity", <a href="https://arxiv.org/abs/1911.02349">arXiv:1911.02349</a> [physics.plasm-ph].</p>
Terrestrial Laser Scans of surface deformation associated with the 11/11/2019 Mw 4.7 Le Teil earthquake (SE France)
<p>Terrestrial Laser Scans of surface deformation produced by the 11/11/2019 Mw 4.7 Le Teil earthquake in SE France.</p> <p>All scans were produced with a Faro X330 equipment at 1/2 resolution, low laser power, with in-field filters (lost points). Processing includes import and registration with Faro Scene software, export as LAS files, manual editing of noise, vegetation and scattered points with CloudCompare software and rasterization with universal kriging with Golden Software Surfer software.</p>
FIGURE 2 from paper JVST-B "Formation of CdSe quantum dots from single source precursor obtained by thermal and laser treatment"
<p>The dataset includes two files: the word file describes the type of sample and the procedures used to pick up the data; the excel file includes the raw data used to obtain the plots of figure 2.</p> <p>In the following is reported the description of figure 2 as wrote in the paper.</p> <p>Absorption and PL spectra (dashed and straight lines, respectively) of the films produced (a) without any ligand, (b) with OA, and (c) with OAm.</p>
DLSI - laser speckle intensity autocorrelation data
<p>Intensity autocorrelation data collected with Dynamic Light Scattering Imaging system. Matlab file contains:</p> <ul> <li>One set of "whole cortex" imaging data, including intensity autocorrelation, spatial and temporal contrasts and best fit data (used to generate Figure 1,2 and S1-S4, S6-S8)</li> <li>A representitative set of stroke imaging: with baseline and after-stroke intensity autocorrelation, contrasts and best fits data (used to generate Figure 3 and S10)</li> <li>Recording parameters (sampling and exposure times).</li> </ul>
LILBID laser dissociation curves: a mass spectrometry-based method for the quantitative assessment of dsDNA binding affinities
<p>The data and data analysis scripts in this dataset are referenced in the manuscript, "LILBID laser dissociation curves: a mass spectrometry-based method for the quantitative assessment of dsDNA binding affinities", which is in preparation for publication. The contents of this dataset are as follows:</p> <p>1) raw data from UV melting curves<br> 2) settings, concentrations, and both raw and processed data from ITC experiments<br> 3) raw spectrum and imaging data from qLILBID experiments<br> 4) programming scripts used to process the qLILBID data</p> <p><em>Notes on the ITC data:</em><br> <em>The iTC200 microcalorimeter (Malvern Panalytical, Malvern, UK) used in the ITC experiments produces .itc files to be opened and analyzed in Origin (Originlab, Northampton, MA, US) using an add-on. The resulting Origin files, including data interpretation and figures, are provided here. Raw data and interpreted data have been gathered from the .itc files and the Origin files and assembled into tab-separated .dat files, so that the data are also accessible to users who do not have Origin.</em></p> <p><em>The Origin files can be understood as follows. After data collection, the ITC raw data are loaded into the Origin-based software. Initially, the baseline is created (Data1Coeff worksheet) and the data plotted in µcal/second as a function of time (minutes), shown in the mRawITC (graph) and the Data1RAW (data) windows. The peaks are integrated (area in µcal) and then plotted in units of kcal/mole of injectant as a function of molar ratio (injected ligand per molecule in the cell), shown in the DeltaH window. The first injection is negligible and therefore always deleted. According to the data points in the DeltaH window, a curve is fitted to obtain the molar ratio (N), Ka, ΔH and ΔS, the data is shown in the Data1 worksheet. The Data1 worksheet hereby contains the following information: DH: heat change resulting from the given injection (µcal/injection); INJV: volume of the injection; Xt: concentration of injected ligand in the cell before next injection; Mt: concentration of molecule in the cell before next injection; volume corrected; XMt: molar ratio of ligand per molecule in the cell after the injection as displayed in the DeltaH window; NDH: Normalized DH in kcal/moles of injectant as displayed in the DeltaH window, Fit: data points of the fitted curve. In the end, the results are presented in the ITCFINAL window (final figure). Additional information can be found in the MicroCal iTC200 System User Manual.</em></p> <p><em>The same data labeling system has been used for the tab-separated .dat files.</em></p>
Data from: Corneal laser procedure for vision improvement in patients with late stage dry age-related macular degeneration
<p><span>Purpose: To determine the safety and efficacy of corneal photovitrification (CPV), a new corneal laser procedure, for vision improvement in patients with late-stage dry age-related macular degeneration (AMD).</span></p> <p><span>Design: Retrospective observational cohort study</span></p> <p><span>Participants: 32 eyes of 17 patients with late-stage dry AMD; each eye received a single CPV corneal laser procedure and had 12 months (12m) post-treatment (Tx) follow-up.</span></p> <p><span>Methods: Pre- and post-Tx examinations included slit-lamp biomicroscopy, subjective manifest refraction, best corrected distance and near visual acuity (BCDVA and BCNVA), and potential visual acuity (PVA). Additional examinations including contrast sensitivity (CS), corneal topography (CT), ray tracing aberrometry (RTA) and microperimetry (MP) were obtained for a subgroup (n=12) of eyes.</span></p> <p><span>Main Outcome Measures: BCDVA, BCNVA, PVA, CS, CT, RTA and MP measurements</span></p> <p><span>Results: Safety - There were no complications or adverse events. Efficacy – Mean (± SD) BCDVA improved significantly (p < 0.004) from 20/238 (1.08 logMAR) at baseline to 20/144 (0.86 logMAR) at 12m post-Tx corresponding to 11.0 (± 13.1) letters gained. Mean contrast sensitivity improved significantly (p < 0.05) by a factor of 1.86 from baseline at 12m post-Tx. </span></p> <p><span>Conclusions: Subject to the limitation of a small sample size, this pilot study indicates that the CPV corneal laser procedure is safe and efficacious for vision improvement in patients with late-stage dry AMD. The CPV Tx mechanism of action involves retinal irradiance distribution modifications that may stimulate patient use of functional, rather than atrophied, retinal regions. </span></p>
Data from: Controlling population of the molecular rotational state and the alignment theoretically by tailored femtosecond laser pulse
We demonstrate that the population of the molecular rotational state through a stimulated impulsive Raman excitation can be controlled by tailoring the femtosecond laser pulse with a V-style phase modulation. The results show that, by precisely manipulating the modulation parameters, both the odd and even populations of the molecular rotational state can be completely suppressed or reconstructed. Meanwhile, the relative excitation between the odd and even populations can be obtained. Finally, we show that field-free molecular alignment can be controlled due to the modulation of the molecular rotational state populations.
Data from: Cavity-mediated collective spin-exchange interactions in a strontium superradiant laser
Laser-cooled and quantum degenerate atoms are being pursued as quantum simulators and form the basis of today's most precise sensors. A key challenge toward these goals is to understand and control coherent interactions between the atoms. We observe long-range exchange interactions mediated by an optical cavity, which manifest as tunable spin-spin interactions on the pseudo spin-½ system composed of the millihertz linewidth clock transition in strontium. This leads to one-axis twisting dynamics, the emergence of a many-body energy gap, and gap protection of the optical coherence against certain sources of decoherence. Our observations will aid in the future design of versatile quantum simulators and the next generation of atomic clocks that use quantum correlations for enhanced metrology.
Laser cladding multispectral coaxial monitoring
<p>This is the first dataset containing data for some single laser cladding tracks when they were observed with NIR and S/MWIR cameras and different IR filters.</p>
Acoustic Monitoring Dataset for Robotic Laser Directed Energy Deposition (LDED) of Maraging Steel C300
<p>This dataset presents a set of acoustic signals captured during a single-bead wall experiment in robotic Laser Directed Energy Deposition (LDED) using Maraging Steel C300. The acoustic data was recorded using a high-fidelity Prepolarized microphone sensor (Xiris WeldMIC), capturing the intricate sound profiles associated with the LDED process at a sampling rate of 44,100 Hz.</p><p><strong>Laser Directed Energy Deposition:</strong></p><p>This dataset was generated with a robotic LDED process that consists of a six-axis industrial robot (KUKA KR90) coupled with a two-axis positioner, a laser head, and a coaxial powder-feeding nozzle.</p><p> </p><p><strong>Folder Structure:</strong></p><ul><li><strong>/sample-1</strong>: The main folder for the experiment sample.<ul><li><strong>/audio_files</strong>: Contains 4624 <strong>.wav</strong> audio files, each representing a 40 ms chunk of the LDED process sound.</li><li><strong>/annotations_1.csv</strong>: A CSV file providing annotations for the audio files, labeling each as "Defect-free", "Defective", or "Laser-off".</li></ul></li><li>audio_features.h5: extracted acoustic features in time-domain, frequency-domain, and time-frequency representations (MFCC features). Feature extraction was conducted using Python Essentia Library.</li></ul><p> </p><p><strong>File Naming Convention:</strong></p><ul><li>Audio files within the <strong>audio_files</strong> folder are named following the pattern <strong>sample_ExperimentID_SampleID.wav</strong>. Given that there's only one experiment and one sample, the naming will be consistent, for example, <strong>sample_1_1.wav</strong> for the first file.</li></ul><p><strong>Annotation Details:</strong></p><ul><li>The <strong>annotations_1.csv</strong> file contains detailed labels for each audio file, correlating to the conditions observed during the experiment, aiding in quick identification and analysis.</li></ul><p><strong>Experimental Parameters:</strong> The dataset reflects a controlled experiment setup with the following specifications:</p><ul><li>Geometry: Single bead wall structure</li><li>Dimensions: 90 mm * 42.5 mm</li><li>Number of layers: 50</li><li>Laser beam diameter: 2 mm</li><li>Layer thickness: 0.85 mm</li><li>Stand-off distance: 12 mm</li><li>Laser profile: Gaussian</li><li>Laser wavelength: 1064 nm</li></ul><p><strong>Process Parameters:</strong></p><ul><li>Laser power: 2.3 kW</li><li>Speed: 25 mm/s</li><li>Dwell time: 0 s</li><li>Powder flow rate: 12 g/min</li></ul><p>This dataset aims to facilitate the development and testing of acoustic-based defect detection models for real-time quality monitoring in LDED processes. It can also serve as a reference point for further research on sensor fusion, machine learning, and real-time monitoring of manufacturing processes.</p>
Dataset for "Application of Digital Twins for Simulation Based Tailoring of Laser Induced Graphene"
Open the record for dataset details and reuse information.
3D drift correction for super-resolution imaging with a single laser light
<p>Original single-molecule image data and analysis results of Figures 4 and 5 in the paper</p>
80 2D laser cutting geometries
<p>.DXF-Format</p>
The data set to paper: Hydrolytic instability of laser-ablatively deposited CaSi2 coatings in air and neutral water affects the behavior of bone healing-related cell types
<p>Main message of this study is focused on calcium silicide (CaSi<sub>2</sub>) instability in humid air or pH-neutral water remains unknown, although the topochemical formation of silicene from CaSi<sub>2</sub> in various aqueous phases is a well-known process. The reseach reports on laser ablation of CaSi<sub>2</sub> in the vacuum and ethanol and examine the instability of the deposited coatings in humid air and neutral water. We further investigate the behavior of human mesenchymal stromal cells (hMSCs), vascular cells (HUVECS, human umbilical vein endothelial cells), and macrophages (derived from THP-1 cell line) in contact with the deposited coatings submerged in cell culture medium. </p>
DATASET - Room Temperature Pulsed Laser Deposition of Aluminum Zinc Oxide (AZO): Enabling Scalable Indium-Free Transparent Conductive Oxides
Open the record for dataset details and reuse information.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.