Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
1,891
datasets available to search
ShareScore release 0.9.0
Dataset results
1,891 results for “Field data”
PSP FIELDS Digital Fields Board (DFB) AC-coupled Searchcoil Magnetometer, SCM, Cross Spectra, e-component, f-component, High Gain, Sensor coordinates, Level 2 (L2), 0.873813 s Data
PSP FIELDS Digital Fields Board (DFB), XXX ⨯ YYY cross spectra data:The DFB is the low frequency, less than 75 kHz, component of the FIELDS experiment on the Parker Solar Probe spacecraft, see reference [1] below. For a full description of the FIELDS experiment, see reference [2]. For a description of the DFB, see reference [3].DFB AC cross spectra data for a pair of input channels consist of:* 1) Power spectral densities (auto spectra, e.g. FT₁ ⨯ FT₁*)* 2) Real and imaginary parts of the spectral cross term (FT₁ ⨯ FT₂*)* 3) Coherence* 4) Phasewhere all as a function of frequency and time. The last two terms are describedcoherence and phase are defined in [3].These cross spectra are averaged in both frequency and time as described in [3]. The cross spectra have either 56 or 96 bins (selectable) with the bin central frequencies reported in the metadata. The AC cross spectra are duty-cycled such that spectral averaging takes place over the first 1/8 of any given NYs (assuming a 1 NYs data cadence). Less data are averaged by 2^N for cadences faster than 1 NYs by 2^N. For cadences slower than 1 NYs, the first 1/8 of each NYs of data included are averaged together to form the reported data.The Level 2 data products contained in this data file have been calibrated for:* 1) The Hanning window used in the spectral calculation* 2) DFB in-band gain* 3) DFB analog filter gain response* 4) DFB digital filter gain response* 5) The search coil preamplifier response, when applicable* 6) The bandwidth of each spectral binNote that compensation for the DFB digital filters will introduce a non-physical positively sloped power trend at high frequencies when the non-corrected signal is dominated by noise. This effect should be examined carefully when determining spectral slopes and features at the highest frequencies. Calibrations for the FIELDS preamplifiers have not been implemented as the preamplifier response is flat and equal to one through the DFB frequency range. Corrections for plasma sheath impedance gain and antenna effective length have not been applied to voltage sensor signals. These corrections will be applied in the Level 3 DFB data products. Therefore, all voltage sensor quantities when present in these Level 2 data products are expressed by using units of Volts squared per Hertz. Likewise, all magnetic field quantities when present in these Level 2 data product are expressed by using units of nanoTesla squared per Hertz. The units for phase are degrees.The Level 2 voltage data products contained in this data file are expressed in sensor coordinates: e.g. dV12, dV34 for voltage measurements. For solar orbits 1 and 2, the search coil magnetometer cross spectra data are rotated into a non-intuitive coordinate system with components [d,e,f]. For solar orbits 3 and beyond, the magnetic field cross spectra data are expressed by using search coil magnetometer sensor coordinates with components [u,v,w].To rotate from [d,e,f] coordinates to [u,v,w] search coil sensor coordinates, use the following matrix, written in IDL notation, and the following equation: spectra_uvw_vector = R ## spectra_def_vector.R = [[ 0.46834856, -0.81336422 , 0.34509170] [ -0.66921924, -0.071546954, 0.73961249] [ -0.57688408, -0.57733845 , -0.57782790]]For some orbits, sufficient spectral information exists in the auto spectra and cross spectra to determine wave ellipticity, planarity, and wave normal angles. One method for accomplishing this is presented in reference [4].Time resolution of the DFB AC cross spectral data can vary by multiples of 2^N. During encounter (when PSP is within 0.25 AU of the Sun), cadence for the DFB AC cross spectra is typically 1 NYsecond [2]. Timestamps correspond to the center time of each window.References:* 1) Fox, N.J., Velli, M.C., Bale, S.D. et al., Space Sci Rev (2016) 204:7. https://doi.org/10.1007/s1121401502116* 2) Bale, S.D., Goetz, K., Harvey, P.R. et al., Space Sci Rev (2016) 204:49. https://doi.org/10.1007/s1121401602445* 3) Malaspina, D.M., Ergun, R.E., Bolton, M. et al., JGR Space Physics (2016), 121, 5088-5096. https://doi.org/10.1002/2016JA022344* 4) Santolik, O., Parrot, M., Lefeuvre, F. Radio Science (2003), 38, 1010. https://doi.org/10.1029/2000RS002523
Whitehorse (WHIT) Ground-based Vector Magnetic Field (L2) 0.5 s Data
Whitehorse, YT, Ground-based Vector Magnetic Field Level 2 Data, 0.5 s Time Resolution, Station Code: (WHIT), Station Location: (GEO Latitude 61.0, Longitude 224.8), THEMIS GBO/UCLA Network
PSP FIELDS Digital Fields Board (DFB) AC-coupled Searchcoil Magnetometer, SCM, Spectra, Medium Frequency, High Gain, x-component, Sensor coordinates, Level 2 (L2), 0.873813 s Data
PSP FIELDS Digital Fields Board, DFB, SCMmf data:The DFB is the low frequency, less than 75 kHz, component of the FIELDS experiment on the Parker Solar Probe spacecraft, see reference [1] below. For a full description of the FIELDS experiment, see reference [2]. For a description of the DFB, see reference [3].DFB AC spectra data consist of power spectral densities as a function of frequency and time. These spectra are averaged over both frequency and time as described in [3]. The spectra have pseudo-logarithmically spaced frequency bins with the bin central frequencies reported in the metadata. The AC spectra are duty-cycled such that spectral averaging takes place over the first 1/8 of any given NYsecond when the data cadence is equal to one NYsecond. Less data are averaged by a factor of 2^N for data cadences that are faster than one NYsecond by 2^N. For cadences slower than one NYsecond, the first 1/8 of each NYsecond of data included are averaged together to construct the reported data.The Level 2 data products contained in this data file have been calibrated for:* 1) The Hanning window used in the spectral calculation* 2) DFB in-band gain* 3) DFB analog filter gain response* 4) DFB digital filter gain response* 5) The search coil preamplifier response, when applicable* 6) The bandwidth of each spectral binNote that compensation for the DFB digital filters will introduce a non-physical positively sloped power trend at high frequencies when the non-corrected signal is dominated by noise. This effect should be examined carefully when determining spectral slopes and features at the highest frequencies. Calibrations for the FIELDS preamplifiers have not been implemented as the preamplifier response is flat and equal to one through the DFB frequency range. Corrections for plasma sheath impedance gain and antenna effective length have not been applied to voltage sensor signals. These corrections will be applied in the Level 3 DFB data products. Therefore, all voltage sensor quantities when present in these Level 2 data products are expressed by using units of Volts squared per Hertz. Likewise, all magnetic field quantities when present in these Level 2 data product are expressed by using units of nanoTesla squared per Hertz.The Level 2 data products contained in this data file are expressed in sensor coordinates: e.g. dV12, dV34 for voltage measurements. For solar orbits 1 and 2, the search coil magnetometer spectral data are rotated into a non-intuitive coordinate system with components [d,e,f]. For solar orbits 3 and beyond, the magnetic field spectral data are in expressed in search coil magnetometer sensor coordinates with components [u,v,w].To rotate from [d,e,f] coordinates into [u,v,w] search coil sensor coordinates, use the following matrix, written in IDL notation, and the following equation: spectra_uvw_vector = R ## spectra_def_vector.R = [[ 0.46834856, -0.81336422 , 0.34509170] [ -0.66921924, -0.071546954, 0.73961249] [ -0.57688408, -0.57733845 , -0.57782790]]The time resolution of the DFB AC spectral data can vary by multiples of 2^N. During encounter when PSP is within 0.25 AU of the Sun, the DFB AC spectra data cadence is typically NYsecond NYsecond [2]. Timestamps correspond to the center time of each window.References:* 1) Fox, N.J., Velli, M.C., Bale, S.D. et al., Space Sci Rev (2016) 204:7. https://doi.org/10.1007/s1121401502116* 2) Bale, S.D., Goetz, K., Harvey, P.R. et al., Space Sci Rev (2016) 204:49. https://doi.org/10.1007/s1121401602445* 3) Malaspina, D.M., Ergun, R.E., Bolton, M. et al., JGR Space Physics (2016), 121, 5088-5096. https://doi.org/10.1002/2016JA022344
PSP FIELDS Digital Fields Board (DFB) DC-coupled Searchcoil Magnetometer, SCM, Spectra, Low Frequency, High Gain, v-component, Sensor coordinates, Level 2 (L2), 6.99054 s Data
PSP FIELDS Digital Fields Board, DFB, SCMvlfhg data:The DFB is the low frequency, less than 75 kHz, component of the FIELDS experiment on the Parker Solar Probe spacecraft, see reference [1] below. For a full description of the FIELDS experiment, see reference [2]. For a description of the DFB, see reference [3].DFB DC spectra data consist of power spectral densities as a function of frequency and time. These spectra are averaged over both frequency and time as described in [3]. The spectra have pseudo-logarithmically spaced frequency bins with the bin central frequencies reported in the metadata.The Level 2 data products contained in this data file have been calibrated for:* 1) The Hanning window used in the spectral calculation* 2) DFB in-band gain* 3) DFB analog filter gain response* 4) DFB digital filter gain response* 5) The search coil preamplifier response, when applicable* 6) The bandwidth of each spectral binNote that compensation for the DFB digital filters will introduce a non-physical positively sloped power trend at high frequencies when the non-corrected signal is dominated by noise. This effect should be examined carefully when determining spectral slopes and features at the highest frequencies. Calibrations for the FIELDS preamplifiers have not been implemented as the preamplifier response is flat and equal to one through the DFB frequency range. Corrections for plasma sheath impedance gain and antenna effective length have not been applied to voltage sensor signals. These corrections will be applied in the Level 3 DFB data products. Therefore, all voltage sensor quantities when present in these Level 2 data products are expressed by using units of Volts squared per Hertz. Likewise, all magnetic field quantities when present in these Level 2 data product are expressed by using units of nanoTesla squared per Hertz.The Level 2 data products contained in this data file are expressed in sensor coordinates: e.g. dV12, dV34 for voltage measurements. For solar orbits 1 and 2, the search coil magnetometer spectral data are rotated into a non-intuitive coordinate system with components [d,e,f]. For solar orbits 3 and beyond, the magnetic field spectral data are in expressed in search coil magnetometer sensor coordinates with components [u,v,w].To rotate from [d,e,f] coordinates into [u,v,w] search coil sensor coordinates, use the following matrix, written in IDL notation, and the following equation: spectra_uvw_vector = R ## spectra_def_vector.R = [[ 0.46834856, -0.81336422 , 0.34509170] [ -0.66921924, -0.071546954, 0.73961249] [ -0.57688408, -0.57733845 , -0.57782790]]The time resolution of the DFB DC spectral data can vary by multiples of 2^N. During encounter when PSP is within 0.25 AU of the Sun, the DFB DC spectra data cadence is typically 30 NYseconds NYsecond [2]. Timestamps correspond to the center time of each window.References:* 1) Fox, N.J., Velli, M.C., Bale, S.D. et al., Space Sci Rev (2016) 204:7. https://doi.org/10.1007/s1121401502116* 2) Bale, S.D., Goetz, K., Harvey, P.R. et al., Space Sci Rev (2016) 204:49. https://doi.org/10.1007/s1121401602445* 3) Malaspina, D.M., Ergun, R.E., Bolton, M. et al., JGR Space Physics (2016), 121, 5088-5096. https://doi.org/10.1002/2016JA022344
PSP FIELDS Digital Fields Board (DFB) AC-coupled Differential Voltage, V1-V2, V3-V4 Antennae, Dipole Mode, Cross Spectra, High Gain, Sensor coordinates, Level 2 (L2), 0.873813 s Data
PSP FIELDS Digital Fields Board (DFB), XXX ⨯ YYY cross spectra data:The DFB is the low frequency, less than 75 kHz, component of the FIELDS experiment on the Parker Solar Probe spacecraft, see reference [1] below. For a full description of the FIELDS experiment, see reference [2]. For a description of the DFB, see reference [3].DFB AC cross spectra data for a pair of input channels consist of:* 1) Power spectral densities (auto spectra, e.g. FT₁ ⨯ FT₁*)* 2) Real and imaginary parts of the spectral cross term (FT₁ ⨯ FT₂*)* 3) Coherence* 4) Phasewhere all as a function of frequency and time. The last two terms are describedcoherence and phase are defined in [3].These cross spectra are averaged in both frequency and time as described in [3]. The cross spectra have either 56 or 96 bins (selectable) with the bin central frequencies reported in the metadata. The AC cross spectra are duty-cycled such that spectral averaging takes place over the first 1/8 of any given NYs (assuming a 1 NYs data cadence). Less data are averaged by 2^N for cadences faster than 1 NYs by 2^N. For cadences slower than 1 NYs, the first 1/8 of each NYs of data included are averaged together to form the reported data.The Level 2 data products contained in this data file have been calibrated for:* 1) The Hanning window used in the spectral calculation* 2) DFB in-band gain* 3) DFB analog filter gain response* 4) DFB digital filter gain response* 5) The search coil preamplifier response, when applicable* 6) The bandwidth of each spectral binNote that compensation for the DFB digital filters will introduce a non-physical positively sloped power trend at high frequencies when the non-corrected signal is dominated by noise. This effect should be examined carefully when determining spectral slopes and features at the highest frequencies. Calibrations for the FIELDS preamplifiers have not been implemented as the preamplifier response is flat and equal to one through the DFB frequency range. Corrections for plasma sheath impedance gain and antenna effective length have not been applied to voltage sensor signals. These corrections will be applied in the Level 3 DFB data products. Therefore, all voltage sensor quantities when present in these Level 2 data products are expressed by using units of Volts squared per Hertz. Likewise, all magnetic field quantities when present in these Level 2 data product are expressed by using units of nanoTesla squared per Hertz. The units for phase are degrees.The Level 2 voltage data products contained in this data file are expressed in sensor coordinates: e.g. dV12, dV34 for voltage measurements. For solar orbits 1 and 2, the search coil magnetometer cross spectra data are rotated into a non-intuitive coordinate system with components [d,e,f]. For solar orbits 3 and beyond, the magnetic field cross spectra data are expressed by using search coil magnetometer sensor coordinates with components [u,v,w].To rotate from [d,e,f] coordinates to [u,v,w] search coil sensor coordinates, use the following matrix, written in IDL notation, and the following equation: spectra_uvw_vector = R ## spectra_def_vector.R = [[ 0.46834856, -0.81336422 , 0.34509170] [ -0.66921924, -0.071546954, 0.73961249] [ -0.57688408, -0.57733845 , -0.57782790]]For some orbits, sufficient spectral information exists in the auto spectra and cross spectra to determine wave ellipticity, planarity, and wave normal angles. One method for accomplishing this is presented in reference [4].Time resolution of the DFB AC cross spectral data can vary by multiples of 2^N. During encounter (when PSP is within 0.25 AU of the Sun), cadence for the DFB AC cross spectra is typically 1 NYsecond [2]. Timestamps correspond to the center time of each window.References:* 1) Fox, N.J., Velli, M.C., Bale, S.D. et al., Space Sci Rev (2016) 204:7. https://doi.org/10.1007/s1121401502116* 2) Bale, S.D., Goetz, K., Harvey, P.R. et al., Space Sci Rev (2016) 204:49. https://doi.org/10.1007/s1121401602445* 3) Malaspina, D.M., Ergun, R.E., Bolton, M. et al., JGR Space Physics (2016), 121, 5088-5096. https://doi.org/10.1002/2016JA022344* 4) Santolik, O., Parrot, M., Lefeuvre, F. Radio Science (2003), 38, 1010. https://doi.org/10.1029/2000RS002523
Hot Springs (HOTS) Ground-based Vector Magnetic Field (L2) 0.5 s Data
Hot Springs, MT, Ground-based Vector Magnetic Field Level 2 Data, 0.5 s Time Resolution, Station Code: (HOTS), Station Location: (GEO Latitude 47.6, Longitude 245.3), THEMIS EPO/UCLA Network
Victoria (VIC) Ground-based Vector Magnetic Field (L2) 1.0 s Data
Victoria, BC, Ground-based Vector Magnetic Field Level 2 Data, 1.0 s Time Resolution, Station Code: (VIC), Station Location: (GEO Latitude 48.5, Longitude 236.6), NRCan Network
Puvirnituq (PUVR) Ground-based Vector Magnetic Field (L2) 0.5 s Data
Puvirnituq, QC, Ground-based Vector Magnetic Field Level 2 Data, 0.5 s Time Resolution, Station Code: (PUVR), Station Location: (GEO Latitude 60.1, Longitude 282.7), AUTUMNX Network
MAVEN Magnetometer (MAG) Magnetic Field and Orbital Position, Sun-State and Payload Coordinates, Level 2 (L2), 1 s Data
The MAVEN Magnetic Field Investigation is Part of a comprehensive Particles and Fields Subsystem that will measure the Magnetic and Electric Fields and Plasma Environment of Mars and its Interaction with the Solar Wind. This Data Product includes Magnetic Field Observations in Sun-State and Payload Coordinates. Sun-State, SS, Coordinate System wherein the Primary Reference Vector, the X-axis, points from the Object, in this case Mars, to the Sun and the Secondary Reference Vector, the Y-axis, is in the Mars Orbit Plane, which is approximately opposite to Orbital Motion Direction, such that the Z-axis is Northward. The Observations Spacecraft Payload, PL, Coordinates are suitable for use in association with Measurements obtained by other Instruments on the Spacecraft. The Spacecraft Payload Coordinate System and the MAG Sensor Coordinate Systems are illustrated in Figure 21 of Connerney et al., 2015. The Text appearing here is also adapted from Connerney et al., 2015.
Lethbridge (LETH) Ground-based Vector Magnetic Field (L2) 0.5 s Data
Lethbridge, AB, Ground-based Vector Magnetic Field Level 2 Data, 0.5 s Time Resolution, Station Code: (LETH), Station Location: (GEO Latitude 49.6, Longitude 247.1), Athabasca University Network
Derby (DRBY) Ground-based Vector Magnetic Field (L2) 0.5 s Data
Derby, VT, Ground-based Vector Magnetic Field Level 2 Data, 0.5 s Time Resolution, Station Code: (DRBY), Station Location: (GEO Latitude 45.0, Longitude 287.9), THEMIS EPO/UCLA Network
Saint-Felicien (STFL) Ground-based Vector Magnetic Field (L2) 0.5 s Data
Saint-Felicien, QC, Ground-based Vector Magnetic Field Level 2 Data, 0.5 s Time Resolution, Station Code: (STFL), Station Location: (GEO Latitude 48.7, Longitude 287.6), AUTUMNX Network
RENU2 COrnell Wire BOom Yo-yo (COWBOY) Electric Field, High Time Resolution (H0), 1 ms Data
Rocket Experiment for Neutral Upwelling 2, RENU2, COrnell Wire BOom Yo-yo, COWBOY, Electric Field Measurements
PSP FIELDS Digital Fields Board (DFB) AC-coupled Searchcoil Magnetometer, SCM, Cross Spectra, d-component, e-component, High Gain, Sensor coordinates, Level 2 (L2), 0.873813 s Data
PSP FIELDS Digital Fields Board (DFB), XXX ⨯ YYY cross spectra data:The DFB is the low frequency, less than 75 kHz, component of the FIELDS experiment on the Parker Solar Probe spacecraft, see reference [1] below. For a full description of the FIELDS experiment, see reference [2]. For a description of the DFB, see reference [3].DFB AC cross spectra data for a pair of input channels consist of:* 1) Power spectral densities (auto spectra, e.g. FT₁ ⨯ FT₁*)* 2) Real and imaginary parts of the spectral cross term (FT₁ ⨯ FT₂*)* 3) Coherence* 4) Phasewhere all as a function of frequency and time. The last two terms are describedcoherence and phase are defined in [3].These cross spectra are averaged in both frequency and time as described in [3]. The cross spectra have either 56 or 96 bins (selectable) with the bin central frequencies reported in the metadata. The AC cross spectra are duty-cycled such that spectral averaging takes place over the first 1/8 of any given NYs (assuming a 1 NYs data cadence). Less data are averaged by 2^N for cadences faster than 1 NYs by 2^N. For cadences slower than 1 NYs, the first 1/8 of each NYs of data included are averaged together to form the reported data.The Level 2 data products contained in this data file have been calibrated for:* 1) The Hanning window used in the spectral calculation* 2) DFB in-band gain* 3) DFB analog filter gain response* 4) DFB digital filter gain response* 5) The search coil preamplifier response, when applicable* 6) The bandwidth of each spectral binNote that compensation for the DFB digital filters will introduce a non-physical positively sloped power trend at high frequencies when the non-corrected signal is dominated by noise. This effect should be examined carefully when determining spectral slopes and features at the highest frequencies. Calibrations for the FIELDS preamplifiers have not been implemented as the preamplifier response is flat and equal to one through the DFB frequency range. Corrections for plasma sheath impedance gain and antenna effective length have not been applied to voltage sensor signals. These corrections will be applied in the Level 3 DFB data products. Therefore, all voltage sensor quantities when present in these Level 2 data products are expressed by using units of Volts squared per Hertz. Likewise, all magnetic field quantities when present in these Level 2 data product are expressed by using units of nanoTesla squared per Hertz. The units for phase are degrees.The Level 2 voltage data products contained in this data file are expressed in sensor coordinates: e.g. dV12, dV34 for voltage measurements. For solar orbits 1 and 2, the search coil magnetometer cross spectra data are rotated into a non-intuitive coordinate system with components [d,e,f]. For solar orbits 3 and beyond, the magnetic field cross spectra data are expressed by using search coil magnetometer sensor coordinates with components [u,v,w].To rotate from [d,e,f] coordinates to [u,v,w] search coil sensor coordinates, use the following matrix, written in IDL notation, and the following equation: spectra_uvw_vector = R ## spectra_def_vector.R = [[ 0.46834856, -0.81336422 , 0.34509170] [ -0.66921924, -0.071546954, 0.73961249] [ -0.57688408, -0.57733845 , -0.57782790]]For some orbits, sufficient spectral information exists in the auto spectra and cross spectra to determine wave ellipticity, planarity, and wave normal angles. One method for accomplishing this is presented in reference [4].Time resolution of the DFB AC cross spectral data can vary by multiples of 2^N. During encounter (when PSP is within 0.25 AU of the Sun), cadence for the DFB AC cross spectra is typically 1 NYsecond [2]. Timestamps correspond to the center time of each window.References:* 1) Fox, N.J., Velli, M.C., Bale, S.D. et al., Space Sci Rev (2016) 204:7. https://doi.org/10.1007/s1121401502116* 2) Bale, S.D., Goetz, K., Harvey, P.R. et al., Space Sci Rev (2016) 204:49. https://doi.org/10.1007/s1121401602445* 3) Malaspina, D.M., Ergun, R.E., Bolton, M. et al., JGR Space Physics (2016), 121, 5088-5096. https://doi.org/10.1002/2016JA022344* 4) Santolik, O., Parrot, M., Lefeuvre, F. Radio Science (2003), 38, 1010. https://doi.org/10.1029/2000RS002523
Bay Mills (BMLS) Ground-based Vector Magnetic Field (L2) 0.5 s Data
Bay Mills, MI, Ground-based Vector Magnetic Field Level 2 Data, 0.5 s Time Resolution, Station Code: (BMLS), Station Location: (GEO Latitude 46.2, Longitude 275.7), THEMIS EPO/UCLA Network
PSP FIELDS Digital Fields Board (DFB) DC-coupled Differential Voltage, V1-V2 Antennae, Dipole Mode, Spectra, High Gain, Sensor coordinates, Level 2 (L2), 6.99054 s Data
PSP FIELDS Digital Fields Board, DFB, dV12hg data:The DFB is the low frequency, less than 75 kHz, component of the FIELDS experiment on the Parker Solar Probe spacecraft, see reference [1] below. For a full description of the FIELDS experiment, see reference [2]. For a description of the DFB, see reference [3].DFB DC spectra data consist of power spectral densities as a function of frequency and time. These spectra are averaged over both frequency and time as described in [3]. The spectra have pseudo-logarithmically spaced frequency bins with the bin central frequencies reported in the metadata.The Level 2 data products contained in this data file have been calibrated for:* 1) The Hanning window used in the spectral calculation* 2) DFB in-band gain* 3) DFB analog filter gain response* 4) DFB digital filter gain response* 5) The search coil preamplifier response, when applicable* 6) The bandwidth of each spectral binNote that compensation for the DFB digital filters will introduce a non-physical positively sloped power trend at high frequencies when the non-corrected signal is dominated by noise. This effect should be examined carefully when determining spectral slopes and features at the highest frequencies. Calibrations for the FIELDS preamplifiers have not been implemented as the preamplifier response is flat and equal to one through the DFB frequency range. Corrections for plasma sheath impedance gain and antenna effective length have not been applied to voltage sensor signals. These corrections will be applied in the Level 3 DFB data products. Therefore, all voltage sensor quantities when present in these Level 2 data products are expressed by using units of Volts squared per Hertz. Likewise, all magnetic field quantities when present in these Level 2 data product are expressed by using units of nanoTesla squared per Hertz.The Level 2 data products contained in this data file are expressed in sensor coordinates: e.g. dV12, dV34 for voltage measurements. For solar orbits 1 and 2, the search coil magnetometer spectral data are rotated into a non-intuitive coordinate system with components [d,e,f]. For solar orbits 3 and beyond, the magnetic field spectral data are in expressed in search coil magnetometer sensor coordinates with components [u,v,w].To rotate from [d,e,f] coordinates into [u,v,w] search coil sensor coordinates, use the following matrix, written in IDL notation, and the following equation: spectra_uvw_vector = R ## spectra_def_vector.R = [[ 0.46834856, -0.81336422 , 0.34509170] [ -0.66921924, -0.071546954, 0.73961249] [ -0.57688408, -0.57733845 , -0.57782790]]The time resolution of the DFB DC spectral data can vary by multiples of 2^N. During encounter when PSP is within 0.25 AU of the Sun, the DFB DC spectra data cadence is typically 30 NYseconds NYsecond [2]. Timestamps correspond to the center time of each window.References:* 1) Fox, N.J., Velli, M.C., Bale, S.D. et al., Space Sci Rev (2016) 204:7. https://doi.org/10.1007/s1121401502116* 2) Bale, S.D., Goetz, K., Harvey, P.R. et al., Space Sci Rev (2016) 204:49. https://doi.org/10.1007/s1121401602445* 3) Malaspina, D.M., Ergun, R.E., Bolton, M. et al., JGR Space Physics (2016), 121, 5088-5096. https://doi.org/10.1002/2016JA022344
PSP FIELDS Digital Fields Board (DFB) DC-coupled Searchcoil Magnetometer, SCM, Cross Spectra, d-component, f-component, High Gain, Sensor coordinates, Level 2 (L2), 0.873813 s Data
PSP FIELDS Digital Fields Board (DFB), SCMXlfhg ⨯ SCMXlfhg cross spectra data:The DFB is the low frequency, less than 75 kHz, component of the FIELDS experiment on the Parker Solar Probe spacecraft, see reference [1] below. For a full description of the FIELDS experiment, see reference [2]. For a description of the DFB, see reference [3].DFB DC cross spectra data for a pair of input channels consist of:* 1) Power spectral densities (auto spectra, e.g. FT₁ ⨯ FT₁*)* 2) Real and imaginary parts of the spectral cross term (FT₁ ⨯ FT₂*)* 3) Coherence* 4) Phasewhere all as a function of frequency and time. The last two terms are describedcoherence and phase are defined in [3].These cross spectra are averaged in both frequency and time as described in [3]. The cross spectra have either 56 or 96 bins (selectable) with the bin central frequencies reported in the metadata.The Level 2 data products contained in this data file have been calibrated for:* 1) The Hanning window used in the spectral calculation* 2) DFB in-band gain* 3) DFB analog filter gain response* 4) DFB digital filter gain response* 5) The search coil preamplifier response, when applicable* 6) The bandwidth of each spectral binNote that compensation for the DFB digital filters will introduce a non-physical positively sloped power trend at high frequencies when the non-corrected signal is dominated by noise. This effect should be examined carefully when determining spectral slopes and features at the highest frequencies. Calibrations for the FIELDS preamplifiers have not been implemented as the preamplifier response is flat and equal to one through the DFB frequency range. Corrections for plasma sheath impedance gain and antenna effective length have not been applied to voltage sensor signals. These corrections will be applied in the Level 3 DFB data products. Therefore, all voltage sensor quantities when present in these Level 2 data products are expressed by using units of Volts squared per Hertz. Likewise, all magnetic field quantities when present in these Level 2 data product are expressed by using units of nanoTesla squared per Hertz. The units for phase are degrees.The Level 2 voltage data products contained in this data file are expressed in sensor coordinates: e.g. dV12, dV34 for voltage measurements. For solar orbits 1 and 2, the search coil magnetometer cross spectra data are rotated into a non-intuitive coordinate system with components [d,e,f]. For solar orbits 3 and beyond, the magnetic field cross spectra data are expressed by using search coil magnetometer sensor coordinates with components [u,v,w].To rotate from [d,e,f] coordinates to [u,v,w] search coil sensor coordinates, use the following matrix, written in IDL notation, and the following equation: spectra_uvw_vector = R ## spectra_def_vector.R = [[ 0.46834856, -0.81336422 , 0.34509170] [ -0.66921924, -0.071546954, 0.73961249] [ -0.57688408, -0.57733845 , -0.57782790]]For some orbits, sufficient spectral information exists in the auto spectra and cross spectra to determine wave ellipticity, planarity, and wave normal angles. One method for accomplishing this is presented in reference [4].Time resolution of the DFB DC cross spectral data can vary by multiples of 2^N. During encounter (when PSP is within 0.25 AU of the Sun), cadence for the DFB DC cross spectra is typically 30 NYseconds [2]. Timestamps correspond to the center time of each window.References:* 1) Fox, N.J., Velli, M.C., Bale, S.D. et al., Space Sci Rev (2016) 204:7. https://doi.org/10.1007/s1121401502116* 2) Bale, S.D., Goetz, K., Harvey, P.R. et al., Space Sci Rev (2016) 204:49. https://doi.org/10.1007/s1121401602445* 3) Malaspina, D.M., Ergun, R.E., Bolton, M. et al., JGR Space Physics (2016), 121, 5088-5096. https://doi.org/10.1002/2016JA022344* 4) Santolik, O., Parrot, M., Lefeuvre, F. Radio Science (2003), 38, 1010. https://doi.org/10.1029/2000RS002523
MMS 4 Search Coil Magnetometer (SCM) AC Magnetic Field Level 2 (L2), Survey Mode, 32 Sample/s Data
Search Coil Magnetometer (SCM) AC Magnetic Field (32 samples/s), Level 2, Survey Mode Data. The tri-axial Search-Coil Magnetometer with its associated preamplifier measures three-dimensional magnetic field fluctuations. The analog magnetic waveforms measured by the SCM are digitized and processed inside the Digital Signal Processor (DSP), collected and stored by the Central Instrument Data Processor (CIDP) via the Fields Central Electronics Box (CEB). Prior to launch, all SCM Flight models were calibrated by LPP team members at the National Magnetic Observatory, Chambon-la-Foret (Orleans). Once per orbit, each SCM transfer function is checked thanks to the onboard calibration signal provided by the DSP. The SCM is operated for the entire MMS orbit in survey mode. Within scientific Regions Of Interest (ROI), burst mode data are also acquired as well as high speed burst mode data. This SCM data set corresponds to the AC magnetic field waveforms in nanoTesla and in the GSE frame. The SCM instrument paper can be found at http://link.springer.com/article/10.1007/s11214-014-0096-9 and the SCM data product guide at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.
Fort Smith (FSMI) Ground-based Vector Magnetic Field (L2) 0.5 s Data
Fort Smith, NT, Ground-based Vector Magnetic Field Level 2 Data, 0.5 s Time Resolution, Station Code: (FSMI), Station Location: (GEO Latitude 60.0, Longitude 248.2), THEMIS GBO/Carisma Network
MMS 2 Electron Drift Instrument (EDI) Electric Field, Level 2 (L2), Survey Mode, 5 s Data
Electron Drift Instrument (EDI) Electric Field Survey, Level 2, 5 s Data. EDI has two scientific data acquisition modes, called electric field mode and ambient mode. In electric field mode, two coded electron beams are emitted such that they return to the detectors after one or more gyrations in the ambient magnetic and electric field. The firing directions and times-of-flight allow the derivation of the drift velocity and electric field. In ambient mode, the electron beams are not used. The detectors with their large geometric factors and their ability to adjust the field of view quickly allow continuous sampling of ambient electrons at a selected pitch angle and fixed but selectable energy. To find the beam directions that will hit the detector, EDI sweeps each beam in the plane perpendicular to B at a fixed angular rate of 0.22 °/ms until a signal has been acquired by the detector. Once signal has been acquired, the beams are swept back and forth to stay on target. Beam detection is not determined from the changes in the count-rates directly, but from the square of the beam counts divided by the background counts from ambient electrons, i.e., from the square of the instantaneous signal-to-noise ratio (SNR). This quantity is computed from data provided by the correlator in the Gun-Detector Electronics that also generates the coding pattern imposed on the outgoing beams. If the squared SNR ratio exceeds a threshold, this is taken as evidence that the beam is returning to the detector. The thresholds for SNR are chosen dependent on background fluxes. They represent a compromise between getting false hits (induced by strong variations in background electron fluxes) and missing true beam hits. The basic software loop that controls EDI operations is executed every 2 ms. As the times when the beams hit their detectors are neither synchronized with the telemetry nor equidistant, EDI data have no fixed time-resolution. Data are reported in telemetry slots. In Survey, using the standard packing mode 0, there are eight telemetry slots per second and Gyn Detector Unit (GDU). The last beam detected during the previous slot will be reported in the current slot. If no beam has been detected, the data quality will be set to zero. In Burst telemetry there are 128 slots per second and GDU. The data in each slot consists of information regarding the beam firing directions (stored in the form of analytic gun deflection voltages), times-of-flight (if successfully measured), quality indicators, time stamps of the beam hits, and some auxiliary correlator-related information. Whenever EDI is not in electron drift mode, it uses its ambient electron mode. The mode has the capability to sample at either 90 degrees pitch angle or at 0/180 degrees (field aligned), or to alternate between 90 degrees and field aligned with selectable dwell times. While all options have been demonstrated during the commissioning phase, only the field aligned mode has been used in the routine operations phase. The choices for energy are 250 eV, 500 eV, and 1 keV. The two detectors, which are facing opposite hemispheres, are looking strictly into opposite directions, so while one detector is looking along B the other is looking antiparallel to B (corresponding to pitch angles of 180 and 0 degrees, respectively). The two detectors switch roles every half spin of the spacecraft as the tip of the magnetic field vector spins outside the field of view of one detector and into the field of view of the other detector. This is the primary data product generated from data collected in electric field mode. The science data generated are drift velocity and electric field data in various coordinate systems. They are derived from triangulation and/or time-of-flight analysis. Where both methods are applicable, their results will be combined using a weighting approach based on their relative errors. The EDI instrument paper can be found at: http://link.springer.com/article/10.1007%2Fs11214-015-0182-7. The EDI instrument data products guide can be found at https://lasp.colorado.edu/mms/sdc/public/datasets/fields/.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.