Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
82
datasets available to search
ShareScore release 0.9.0
Dataset results
82 results for “3D ultrasound”
Deep and complex vascular anatomy in the rat brain described with Ultrasound Localization Microscopy in 3D
<p><strong>Abstract:</strong></p><p>Ultrasound Localization Microscopy (<strong>ULM</strong>) enables imaging microvessels in the brain with a resolution of a few tens of micrometers <i>in vivo</i>. The planar architecture of arterioles and venules was revealed with a 2D ultrasound scanner in the cortex of the rat brain. However, deeper in the brain, where the vascularization becomes tri-dimensional, 2D imaging remains limited by the elevation projection. In this study, volumetric ultrasound imaging was performed in the craniotomized rat brain to yield 3D ULM<i> in vivo</i> within 7.5 min of acquisition with a commercial system. For instance, it highlighted the thalamus or the circle of Willis with small vessels down to 21 µm. Microbubbles tracking also gave access to the 3D velocity vector of blood flow allowing to distinguish flow directions. Volumetric ULM resolved deep complex tri-dimensional vascular structures and was compared to 2D ULM. It is a safe, simple and repeatable system to image wide field of view in the brain.</p><p><strong>Data Description:</strong></p><p>Microbubbles have been detected, localized, and tracking with 3D ultrasound imaging <i>in vivo</i> in a rat brain with skull removal.</p><p>Individual microbubble trajectories are described in 4 columns vectores: <strong>[z, x, y, time]</strong> for each position of the path. Space positions are given in [mm], and times are given in [ms]. Trajectories data are stored in .mat files (<strong>tracks_0xx.mat </strong>and zipped inside <strong>tracks.zip</strong>) as cell arrays.</p><p>Tracks can be binned inside a volumetric grid with the sample code (<strong>ULM_rendering.m</strong>).</p><p><strong>Reference to be cited: </strong>Chavignon, Heiles, Hingot, Orset, Vivien and Couture.</p><p><i>Deep and complex vascular anatomy in the rat brain described with Ultrasound Localization Microscopy in 3D.</i><br> </p>
Trackerless 3D Freehand Ultrasound Reconstruction Challenge 2024 - Train Dataset (Part 2)
<blockquote> <p><strong>This Challenge will be an open-ended challenge, and we welcome your submission. Please register your team via this <a title="https://forms.office.com/e/dPg47ktV7M" href="https://forms.office.com/e/dPg47ktV7M" target="_blank" rel="noopener">form</a>. You can submit the algorithm via this <a title="https://forms.office.com/e/QChhNkLYiu" href="https://forms.office.com/e/QChhNkLYiu" target="_blank" rel="noopener noreferrer">form</a> for TUS-REC2024 Challenge, and we will test your submitted docker on the test set.</strong></p> <p><strong>We are organising TUS-REC2025 at MICCAI2025. More information is available on the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/" target="_blank" rel="noopener">TUS-REC2025 challenge website</a> and <a href="https://github.com/QiLi111/TUS-REC2025-Challenge_baseline" target="_blank" rel="noopener">Baseline code repo</a>.</strong></p> </blockquote> <p><strong>This is the second part of the Challenge dataset. <a href="../doi/10.5281/zenodo.11178509" target="_blank" rel="noopener">Link</a> to first part; <a href="../doi/10.5281/zenodo.11355500" target="_blank" rel="noopener">Link</a> to third part. <a href="../doi/10.5281/zenodo.12979481" target="_blank" rel="noopener">Link</a> to validation dataset.</strong></p> <p>Acquisition devices and config: The 2D US images were acquired using an Ultrasonix machine (BK, Europe) with a curvilinear probe (4DC7-3/40). The associated position information of each frame was recorded by an optical tracker (NDI Polaris Vicra, Northern Digital Inc., Canada). The acquired US frames were recorded at 20 fps, with an image size of 480×640, without speckle reduction. The frequency was set at 6MHz with a dynamic range of 83 dB, an overall gain of 48% and a depth of 9 cm. </p> <div> <p>Scanning protocol: Both left and right forearms of volunteers were scanned. For each forearm, the US probe moves in three different trajectories (straight line shape, "C" shape, and "S" shape), in a distal-to-proximal direction followed by a proximal-to-distal direction, with the US plane perpendicular of and parallel to the scanning direction. The train dataset contains 1200 scans in total, 24 scans associated with each subject.</p> <div> <div> <p>For detailed information please refer to the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/TUS-REC2024/" target="_blank" rel="noopener">Challenge website</a>. Baseline code is also provided, which can be found at this <a href="https://github.com/QiLi111/tus-rec-challenge_baseline" target="_blank" rel="noopener">repo</a>.</p> <p>Dataset structure: </p> </div> <div> <ul> <li> <p>The dataset contains 50 folders (one subject per folder), each with 24 scans. Each .h5 file corresponds to one scan, storing image and transformation of each frame within this scan. Key-value pairs in each .h5 file are explained below.</p> <ul> <li> <p>“frames” - All frames in the scan; with a shape of [N,H,W], where N refers to the number of frames in the scan, H and W denote the height and width of a frame. </p> </li> <li> <p>“tforms” - All transformations in the scan; with a shape of [N,4,4], where N is the number of frames in the scan, and the transformation matrix denotes the transformation from tracker tool space to camera space. </p> </li> <li> <p>Notations in the name of each .h5 file: “RH”: right arm; “LH”: left arm; “Per”: perpendicular; “Par”: parallel; “L”: straight line shape; “C”: C shape; “S”: S shape; “DtP”: distal-to-proximal direction; “PtD”: proximal-to-distal direction; For example, “RH_Per_L_DtP.h5” denotes a scan on the right forearm, with ultrasound probe perpendicular of the forearm sweeping along straight line, in distal-to-proximal direction.</p> </li> </ul> </li> <li> <p>Calibration matrix: The calibration matrix was obtained using a pinhead-based method. The "scaling_from_pixel_to_mm" and "spatial_calibration_from_image_coordinate_system_to_tracking_tool_coordinate_system" are provided in the “calib_matrix.csv”. </p> </li> </ul> <div> <p><strong>Data Usage Policy:</strong></p> <ul> <li>The training and validation data provided may be utilized within the research scope of this challenge and in subsequent research-related publications. However, commercial use of the training and validation data is prohibited. In cases where the intended use is ambiguous, participants accessing the data are requested to abstain from further distribution or use outside the scope of this challenge.</li> <li>If you use our dataset in your publication, please cite the challenge paper and some of the following optional articles: <ul> <li>Challenge paper: <ul> <li><strong>Qi Li et al. "TUS-REC2024: A Challenge to Reconstruct 3D Freehand Ultrasound Without External Tracker." <em>arXiv preprint arXiv:<a title="https://arxiv.org/abs/2506.21765" href="https://doi.org/10.48550/arXiv.2506.21765" target="_blank" rel="noopener">2506.21765</a></em> (2025).</strong></li> </ul> </li> <li>Optional articles: <ul> <li>Qi Li, Ziyi Shen, Qianye Yang, Dean C. Barratt, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Nonrigid Reconstruction of Freehand Ultrasound without a Tracker." In <em>International Conference on Medical Image Computing and Computer-Assisted Intervention</em>, pp. 689-699. Cham: Springer Nature Switzerland, 2024. doi: <a href="https://doi.org/10.1007/978-3-031-72083-3_64" target="_blank" rel="noopener">10.1007/978-3-031-72083-3_64.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Long-term Dependency for 3D Reconstruction of Freehand Ultrasound Without External Tracker." IEEE Transactions on Biomedical Engineering, vol. 71, no. 3, pp. 1033-1042, 2024. doi: <a href="https://ieeexplore.ieee.org/abstract/document/10288201" target="_blank" rel="noopener">10.1109/TBME.2023.3325551</a>.</li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Trackerless freehand ultrasound with sequence modelling and auxiliary transformation over past and future frames." In 2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2023. doi: <a href="https://doi.org/10.1109/ISBI53787.2023.10230773" target="_blank" rel="noopener">10.1109/ISBI53787.2023.10230773.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Privileged Anatomical and Protocol Discrimination in Trackerless 3D Ultrasound Reconstruction." In International Workshop on Advances in Simplifying Medical Ultrasound, pp. 142-151. Cham: Springer Nature Switzerland, 2023. doi: <a href="https://doi.org/10.1007/978-3-031-44521-7_14" target="_blank" rel="noopener">https://doi.org/10.1007/978-3-031-44521-7_14.</a></li> </ul> </li> </ul> </li> </ul> </div> </div> </div> </div>
Trackerless 3D Freehand Ultrasound Reconstruction Challenge 2024 - Train Dataset (Part 1)
<blockquote> <p><strong>This Challenge will be an open-ended challenge, and we welcome your submission. Please register your team via this <a title="https://forms.office.com/e/dPg47ktV7M" href="https://forms.office.com/e/dPg47ktV7M" target="_blank" rel="noopener">form</a>. You can submit the algorithm via this <a title="https://forms.office.com/e/QChhNkLYiu" href="https://forms.office.com/e/QChhNkLYiu" target="_blank" rel="noopener noreferrer">form</a> for TUS-REC2024 Challenge, and we will test your submitted docker on the test set.</strong></p> <p><strong>We are organising TUS-REC2025 at MICCAI2025. More information is available on the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/" target="_blank" rel="noopener">TUS-REC2025 challenge website</a> and <a href="https://github.com/QiLi111/TUS-REC2025-Challenge_baseline" target="_blank" rel="noopener">Baseline code repo</a>.</strong></p> </blockquote> <p><strong>This is the first part of the Challenge train dataset. <a href="../doi/10.5281/zenodo.11180795" target="_blank" rel="noopener">Link</a> to second part; <a href="../doi/10.5281/zenodo.11355499" target="_blank" rel="noopener">Link</a> to third part. <a href="../doi/10.5281/zenodo.12979481" target="_blank" rel="noopener">Link</a> to validation dataset.</strong></p> <p>Acquisition devices and config: The 2D US images were acquired using an Ultrasonix machine (BK, Europe) with a curvilinear probe (4DC7-3/40). The associated position information of each frame was recorded by an optical tracker (NDI Polaris Vicra, Northern Digital Inc., Canada). The acquired US frames were recorded at 20 fps, with an image size of 480×640, without speckle reduction. The frequency was set at 6MHz with a dynamic range of 83 dB, an overall gain of 48% and a depth of 9 cm. </p> <div> <p>Scanning protocol: Both left and right forearms of volunteers were scanned. For each forearm, the US probe moves in three different trajectories (straight line shape, "C" shape, and "S" shape), in a distal-to-proximal direction followed by a proximal-to-distal direction, with the US plane perpendicular of and parallel to the scanning direction. The train dataset contains 1200 scans in total, 24 scans associated with each subject.</p> <p>For detailed information please refer to the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/TUS-REC2024/" target="_blank" rel="noopener">Challenge website</a>. Baseline code is also provided, which can be found at this <a href="https://github.com/QiLi111/tus-rec-challenge_baseline" target="_blank" rel="noopener">repo</a>.</p> <p>Dataset structure: </p> </div> <div> <ul> <li> <p>The dataset contains 50 folders (one subject per folder), each with 24 scans. Each .h5 file corresponds to one scan, storing image and transformation of each frame within this scan. Key-value pairs in each .h5 file are explained below.</p> <ul> <li> <p>“frames” - All frames in the scan; with a shape of [N,H,W], where N refers to the number of frames in the scan, H and W denote the height and width of a frame. </p> </li> <li> <p>“tforms” - All transformations in the scan; with a shape of [N,4,4], where N is the number of frames in the scan, and the transformation matrix denotes the transformation from tracker tool space to camera space. </p> </li> <li> <p>Notations in the name of each .h5 file: “RH”: right arm; “LH”: left arm; “Per”: perpendicular; “Par”: parallel; “L”: straight line shape; “C”: C shape; “S”: S shape; “DtP”: distal-to-proximal direction; “PtD”: proximal-to-distal direction; For example, “RH_Per_L_DtP.h5” denotes a scan on the right forearm, with ultrasound probe perpendicular of the forearm sweeping along straight line, in distal-to-proximal direction.</p> </li> </ul> </li> <li> <p>Calibration matrix: The calibration matrix was obtained using a pinhead-based method. The "scaling_from_pixel_to_mm" and "spatial_calibration_from_image_coordinate_system_to_tracking_tool_coordinate_system" are provided in the “calib_matrix.csv”. </p> </li> </ul> <div> <p><strong>Data Usage Policy:</strong></p> <ul> <li>The training and validation data provided may be utilized within the research scope of this challenge and in subsequent research-related publications. However, commercial use of the training and validation data is prohibited. In cases where the intended use is ambiguous, participants accessing the data are requested to abstain from further distribution or use outside the scope of this challenge.</li> <li>If you use our dataset in your publication, please cite the challenge paper and some of the following optional articles: <ul> <li>Challenge paper: <ul> <li><strong>Qi Li et al. "TUS-REC2024: A Challenge to Reconstruct 3D Freehand Ultrasound Without External Tracker." <em>arXiv preprint arXiv:<a title="https://arxiv.org/abs/2506.21765" href="https://doi.org/10.48550/arXiv.2506.21765" target="_blank" rel="noopener">2506.21765</a></em> (2025).</strong></li> </ul> </li> <li>Optional articles: <ul> <li>Qi Li, Ziyi Shen, Qianye Yang, Dean C. Barratt, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Nonrigid Reconstruction of Freehand Ultrasound without a Tracker." In <em>International Conference on Medical Image Computing and Computer-Assisted Intervention</em>, pp. 689-699. Cham: Springer Nature Switzerland, 2024. doi: <a href="https://doi.org/10.1007/978-3-031-72083-3_64" target="_blank" rel="noopener">10.1007/978-3-031-72083-3_64.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Long-term Dependency for 3D Reconstruction of Freehand Ultrasound Without External Tracker." IEEE Transactions on Biomedical Engineering, vol. 71, no. 3, pp. 1033-1042, 2024. doi: <a href="https://ieeexplore.ieee.org/abstract/document/10288201" target="_blank" rel="noopener">10.1109/TBME.2023.3325551</a>.</li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Trackerless freehand ultrasound with sequence modelling and auxiliary transformation over past and future frames." In 2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2023. doi: <a href="https://doi.org/10.1109/ISBI53787.2023.10230773" target="_blank" rel="noopener">10.1109/ISBI53787.2023.10230773.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Privileged Anatomical and Protocol Discrimination in Trackerless 3D Ultrasound Reconstruction." In International Workshop on Advances in Simplifying Medical Ultrasound, pp. 142-151. Cham: Springer Nature Switzerland, 2023. doi: <a href="https://doi.org/10.1007/978-3-031-44521-7_14" target="_blank" rel="noopener">https://doi.org/10.1007/978-3-031-44521-7_14.</a></li> </ul> </li> </ul> </li> </ul> </div> </div>
Trackerless 3D Freehand Ultrasound Reconstruction Challenge 2024 - Train Dataset (Part 3)
<div> <blockquote> <p><strong>This Challenge will be an open-ended challenge, and we welcome your submission. Please register your team via this <a title="https://forms.office.com/e/dPg47ktV7M" href="https://forms.office.com/e/dPg47ktV7M" target="_blank" rel="noopener">form</a>. You can submit the algorithm via this <a title="https://forms.office.com/e/QChhNkLYiu" href="https://forms.office.com/e/QChhNkLYiu" target="_blank" rel="noopener noreferrer">form</a> for TUS-REC2024 Challenge, and we will test your submitted docker on the test set.</strong></p> <p><strong>We are organising TUS-REC2025 at MICCAI2025. More information is available on the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/" target="_blank" rel="noopener">TUS-REC2025 challenge website</a> and <a href="https://github.com/QiLi111/TUS-REC2025-Challenge_baseline" target="_blank" rel="noopener">Baseline code repo</a>.</strong></p> </blockquote> <p><strong>This is the third part of the Challenge dataset. <a href="../doi/10.5281/zenodo.11178509" target="_blank" rel="noopener">Link</a> to first part; <a href="../doi/10.5281/zenodo.11180795" target="_blank" rel="noopener">Link</a> to second part. <a href="../doi/10.5281/zenodo.12979481" target="_blank" rel="noopener">Link</a> to validation dataset.</strong></p> <p>For detailed information please refer to the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/TUS-REC2024/" target="_blank" rel="noopener">Challenge website</a>. Baseline code is also provided, which can be found at this <a href="https://github.com/QiLi111/tus-rec-challenge_baseline" target="_blank" rel="noopener">repo</a>.</p> <p>Dataset structure: The dataset contains 50 .h5 files. Each corresponds to one subject, storing coordinates of landmarks for 24 scans of this subject. For each scan, the coordinates are stored in numpy array with shape of [20,3]. The first column is the index of frames; the second and third columns denote the coordinates of landmarks in the image coordinate system. </p> </div> <div> <p> </p> <p><strong>Data Usage Policy:</strong></p> <ul> <li>The training and validation data provided may be utilized within the research scope of this challenge and in subsequent research-related publications. However, commercial use of the training and validation data is prohibited. In cases where the intended use is ambiguous, participants accessing the data are requested to abstain from further distribution or use outside the scope of this challenge.</li> <li>If you use our dataset in your publication, please cite the challenge paper and some of the following optional articles: <ul> <li>Challenge paper: <ul> <li><strong>Qi Li et al. "TUS-REC2024: A Challenge to Reconstruct 3D Freehand Ultrasound Without External Tracker." <em>arXiv preprint arXiv:<a title="https://arxiv.org/abs/2506.21765" href="https://doi.org/10.48550/arXiv.2506.21765" target="_blank" rel="noopener">2506.21765</a></em> (2025).</strong></li> </ul> </li> <li>Optional articles: <ul> <li>Qi Li, Ziyi Shen, Qianye Yang, Dean C. Barratt, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Nonrigid Reconstruction of Freehand Ultrasound without a Tracker." In <em>International Conference on Medical Image Computing and Computer-Assisted Intervention</em>, pp. 689-699. Cham: Springer Nature Switzerland, 2024. doi: <a href="https://doi.org/10.1007/978-3-031-72083-3_64" target="_blank" rel="noopener">10.1007/978-3-031-72083-3_64.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Long-term Dependency for 3D Reconstruction of Freehand Ultrasound Without External Tracker." IEEE Transactions on Biomedical Engineering, vol. 71, no. 3, pp. 1033-1042, 2024. doi: <a href="https://ieeexplore.ieee.org/abstract/document/10288201" target="_blank" rel="noopener">10.1109/TBME.2023.3325551</a>.</li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Trackerless freehand ultrasound with sequence modelling and auxiliary transformation over past and future frames." In 2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2023. doi: <a href="https://doi.org/10.1109/ISBI53787.2023.10230773" target="_blank" rel="noopener">10.1109/ISBI53787.2023.10230773.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Privileged Anatomical and Protocol Discrimination in Trackerless 3D Ultrasound Reconstruction." In International Workshop on Advances in Simplifying Medical Ultrasound, pp. 142-151. Cham: Springer Nature Switzerland, 2023. doi: <a href="https://doi.org/10.1007/978-3-031-44521-7_14" target="_blank" rel="noopener">https://doi.org/10.1007/978-3-031-44521-7_14.</a></li> </ul> </li> </ul> </li> </ul> </div>
Trackerless 3D Freehand Ultrasound Reconstruction Challenge 2024 - Validation Dataset
<blockquote> <p><strong>This Challenge will be an open-ended challenge, and we welcome your submission. Please register your team via this <a title="https://forms.office.com/e/dPg47ktV7M" href="https://forms.office.com/e/dPg47ktV7M" target="_blank" rel="noopener">form</a>. You can submit the algorithm via this <a title="https://forms.office.com/e/QChhNkLYiu" href="https://forms.office.com/e/QChhNkLYiu" target="_blank" rel="noopener noreferrer">form</a> for TUS-REC2024 Challenge, and we will test your submitted docker on the test set.</strong></p> <p><strong>We are organising TUS-REC2025 at MICCAI2025. More information is available on the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/" target="_blank" rel="noopener">TUS-REC2025 challenge website</a> and <a href="https://github.com/QiLi111/TUS-REC2025-Challenge_baseline" target="_blank" rel="noopener">Baseline code repo</a>.</strong></p> </blockquote> <p><strong>This is the validation dataset. The training dataset is available at <a href="../doi/10.5281/zenodo.11178508" target="_blank" rel="noopener">Part1</a>, <a href="../doi/10.5281/zenodo.11180795" target="_blank" rel="noopener">Part2</a>, and <a href="../doi/10.5281/zenodo.11355499" target="_blank" rel="noopener">Part3</a>.</strong></p> <p>Acquisition devices and config: The 2D US images were acquired using an Ultrasonix machine (BK, Europe) with a curvilinear probe (4DC7-3/40). The associated position information of each frame was recorded by an optical tracker (NDI Polaris Vicra, Northern Digital Inc., Canada). The acquired US frames were recorded at 20 fps, with an image size of 480×640, without speckle reduction. The frequency was set at 6MHz with a dynamic range of 83 dB, an overall gain of 48% and a depth of 9 cm. </p> <div> <p>Scanning protocol: Both left and right forearms of volunteers were scanned. For each forearm, the US probe moves in three different trajectories (straight line shape, "C" shape, and "S" shape), in a distal-to-proximal direction followed by a proximal-to-distal direction, with the US plane perpendicular of and parallel to the scanning direction. The validation dataset contains 72 scans in total, 24 scans associated with each subject.</p> <p>For detailed information please refer to the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/TUS-REC2024/" target="_blank" rel="noopener">Challenge website</a>. Baseline code is also provided, which can be found at this <a href="https://github.com/QiLi111/tus-rec-challenge_baseline" target="_blank" rel="noopener">repo</a>.</p> <p>Dataset structure: </p> <ul> <li>Folder <code>frames</code>: contains three folders (one subject per folder), each with 24 scans. Each .h5 file corresponds to one scan, storing image of each frame within this scan. Key-value pair and name of each .h5 file are explained below. <ul> <li>“frames” - All frames in the scan; with a shape of [N,H,W], where N refers to the number of frames in the scan, H and W denote the height and width of a frame. </li> <li>Notations in the name of each .h5 file: “RH”: right arm; “LH”: left arm; “Per”: perpendicular; “Par”: parallel; “L”: straight line shape; “C”: C shape; “S”: S shape; “DtP”: distal-to-proximal direction; “PtD”: proximal-to-distal direction; For example, “RH_Per_L_DtP.h5” denotes a scan on the right forearm, with ultrasound probe perpendicular of the forearm sweeping along straight line, in distal-to-proximal direction.</li> </ul> </li> </ul> </div> <div> <ul> <li>Folder <code>transfs</code>: contains three folders (one subject per folder), each with 24 scans. Each .h5 file corresponds to one scan, storing transformation of each frame within this scan. Key-value pair and name of each .h5 file are explained below. <ul> <li>“tforms” - All transformations in the scan; with a shape of [N,4,4], where N is the number of frames in the scan, and the transformation matrix denotes the transformation from tracker tool space to camera space. </li> <li>Notations in the name of each .h5 file is the same as in folder <code>frames</code>.</li> </ul> </li> <li>Folder <code>landmark</code>: contains three .h5 files. Each corresponds to one subject, storing coordinates of landmarks for 24 scans of this subject. For each scan, the coordinates are stored in numpy array with a shape of [20,3]. The first column is the index of frame; the second and third columns denote the coordinates of landmarks in the image coordinate system.</li> <li><code>calib_matrix.csv</code>: The calibration matrix was obtained using a pinhead-based method. The "scaling_from_pixel_to_mm" and "spatial_calibration_from_image_coordinate_system_to_tracking_tool_coordinate_system" are provided in the “calib_matrix.csv”.</li> <li><code>dataset_keys.h5</code>: stores the paths to all the scans of the data set. Keys in “dataset_keys.h5” denotes all the available scans in validation set, in a format of “sub%03d__%s” where %03d denotes folder name, and %s denotes the scan name. For example, “sub050__LH_Par_C_DtP” means the scan in folder “050”, with file name of “LH_Par_C_DtP.h5”</li> </ul> <div> <p><strong>Data Usage Policy:</strong></p> <ul> <li>The training and validation data provided may be utilized within the research scope of this challenge and in subsequent research-related publications. However, commercial use of the training and validation data is prohibited. In cases where the intended use is ambiguous, participants accessing the data are requested to abstain from further distribution or use outside the scope of this challenge.</li> <li><span>If you use our dataset in your publication, </span>please cite the challenge paper and some of the following optional articles: <ul> <li>Challenge paper: <ul> <li><strong>Qi Li et al. "TUS-REC2024: A Challenge to Reconstruct 3D Freehand Ultrasound Without External Tracker." <em>arXiv preprint arXiv:<a title="https://arxiv.org/abs/2506.21765" href="https://doi.org/10.48550/arXiv.2506.21765" target="_blank" rel="noopener">2506.21765</a></em> (2025).</strong></li> </ul> </li> <li>Optional articles:<br> <ul> <li>Qi Li, Ziyi Shen, Qianye Yang, Dean C. Barratt, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Nonrigid Reconstruction of Freehand Ultrasound without a Tracker." In <em>International Conference on Medical Image Computing and Computer-Assisted Intervention</em>, pp. 689-699. Cham: Springer Nature Switzerland, 2024. doi: <a href="https://doi.org/10.1007/978-3-031-72083-3_64" target="_blank" rel="noopener">10.1007/978-3-031-72083-3_64.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Long-term Dependency for 3D Reconstruction of Freehand Ultrasound Without External Tracker." IEEE Transactions on Biomedical Engineering, vol. 71, no. 3, pp. 1033-1042, 2024. doi: <a href="https://ieeexplore.ieee.org/abstract/document/10288201" target="_blank" rel="noopener">10.1109/TBME.2023.3325551</a>.</li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Trackerless freehand ultrasound with sequence modelling and auxiliary transformation over past and future frames." In 2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2023. doi: <a href="https://doi.org/10.1109/ISBI53787.2023.10230773" target="_blank" rel="noopener">10.1109/ISBI53787.2023.10230773.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Privileged Anatomical and Protocol Discrimination in Trackerless 3D Ultrasound Reconstruction." In International Workshop on Advances in Simplifying Medical Ultrasound, pp. 142-151. Cham: Springer Nature Switzerland, 2023. doi: <a href="https://doi.org/10.1007/978-3-031-44521-7_14" target="_blank" rel="noopener">https://doi.org/10.1007/978-3-031-44521-7_14.</a></li> </ul> </li> </ul> </li> </ul> </div> </div>
The Effect of Pregnancy and Labour on the Pelvic Floor Diagnosed With 3D and 4D Ultrasound
ClinicalTrials.gov study NCT01045135. IPD Sharing: Not stated. Countries: 1. Publications: 1.
Evaluation of 3D Ultrasound in Brain Tumor Surgery
ClinicalTrials.gov study NCT05956977. IPD Sharing: NO. Countries: 1. Publications: 1.
Evaluation of the Functional Outcomes After Bilateral, 3D Ultrasound-guided Focal Thermal Ablation of the Prostate Transition Zone, in Patients with Benign Prostatic Hyperplasia-related Obstruction
ClinicalTrials.gov study NCT06212453. IPD Sharing: NO. Countries: 1. Publications: 6.
Comparing a New 3D Technology Used to Measure Thyroid Nodule Volume to Standard Ultrasound
ClinicalTrials.gov study NCT07178080. IPD Sharing: NO. Countries: 1. Publications: 3.
Effect of Cilostazol on Carotid Atherosclerosis Estimated by 3D Ultrasound in Patients With Type 2 Diabetes
ClinicalTrials.gov study NCT03248401. IPD Sharing: Not stated. Countries: 1. Publications: 3.
Implantation Prediction by Three Dimensional (3D) Ultrasound in Fresh Embryo Transfers
ClinicalTrials.gov study NCT02817373. IPD Sharing: NO. Countries: 1. Publications: 3.
Ex Vivo 3D-ultrasound for Oropharyngeal Cancer
ClinicalTrials.gov study NCT06314711. IPD Sharing: NO. Countries: 1. Publications: 1.
Surgical Margin Assessment by 3D Ultrasound
ClinicalTrials.gov study NCT05740774. IPD Sharing: YES. Countries: 1. Publications: 8.
3D Transcranial Ultrasound Brain Imaging (3D-TRUBI) Instrument for Point-of-Care Diagnosis of Intracranial Hemorrhages
ClinicalTrials.gov study NCT06780436. IPD Sharing: NO. Countries: 1. Publications: 1.
3D Ultrasound Myocardial Mechanical Wave Measurements
ClinicalTrials.gov study NCT06648577. IPD Sharing: UNDECIDED. Countries: 1. Publications: 1.
Clinical Evaluation of Navigated 3D Ultrasound Multicentre Study
ClinicalTrials.gov study NCT00233350. IPD Sharing: Not stated. Countries: 1. Publications: 1.
Optimization of Fetal Biometry With 3D Ultrasound and Image Recognition
ClinicalTrials.gov study NCT03812471. IPD Sharing: NO. Countries: 1. Publications: 1.
3D Ultrasound, Specimen Examination by Surgeon, and MRI in Surgical Margin Assessment
ClinicalTrials.gov study NCT05843032. IPD Sharing: YES. Countries: 1. Publications: 9.
3D Ultrasound Uterine Characteristics of Women Undergoing IVF/ICSI Treatment
ClinicalTrials.gov study NCT02549235. IPD Sharing: NO. Countries: 1. Publications: 7.
Natural History of Carotid Plaque as Determined by 3D Ultrasound
ClinicalTrials.gov study NCT03314818. IPD Sharing: Not stated. Countries: 1. Publications: 4.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.