Skip to main content
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

8

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

8 results for “Dynamic Torques”

Learn how ShareScore rates datasets ↗
zenodo44/100

Terahertz Néel spin-orbit torques drive nonlinear magnon dynamics in antiferromagnetic Mn2Au

<p>Data for the publication &quot;<strong>Terahertz N&eacute;el spin-orbit torques drive nonlinear magnon dynamics in antiferromagnetic Mn<sub>2</sub>Au&quot;</strong>, published in <em>Nat Commun</em> <strong>14</strong>, 6038 (2023). (https://doi.org/10.1038/s41467-023-41569-z).</p> <p>A preprint (2023) can be found on arxiv (https://doi.org/10.48550/arXiv.2305.03368).</p> <p>The datasets are provided for Figures 2-4.</p> <p>Files are provided as comma-separated text files with column headers. The value delimiter is comma &quot; , &quot;. The decimal separator is period &quot; . &quot;</p>

opencc-by-4.0Aug 2023View details →
zenodo36/100

Flow Magnetic Tweezers: Gyrase dynamics under 3 different external torque conditions. Part 1/3

<p>The video contains a whole field from a force spectroscopy experiment called Flow Magnetic Tweezers (FMT). It shows E. coli DNA Gyrase manipulating DNA topology by relaxing positive and introducing negative coils as well as response of gyrase to external torque of 2, 4 and 8 positive magnet turns. Part 1/3</p>

opencc-by-4.0Aug 2020View details →
zenodo36/100

Flow Magnetic Tweezers: Gyrase dynamics under 3 different external torque conditions. Part 3/3

<p>The video contains a whole field from a force spectroscopy experiment called Flow Magnetic Tweezers (FMT). It shows E. coli DNA Gyrase manipulating DNA topology by relaxing positive and introducing negative coils as well as response of gyrase to external torque of 2, 4 and 8 positive magnet turns. Part 3/3</p>

opencc-by-4.0Aug 2020View details →
zenodo36/100

Flow Magnetic Tweezers: Gyrase dynamics under 3 different external torque conditions. Part 2/3

<p>The video contains a whole field from a force spectroscopy experiment called Flow Magnetic Tweezers (FMT). It shows E. coli DNA Gyrase manipulating DNA topology by relaxing positive and introducing negative coils as well as response of gyrase to external torque of 2, 4 and 8 positive magnet turns. Part 2/3</p>

opencc-by-4.0Aug 2020View details →
dryad32/100

Data from: Biomechanical evaluation of peak reverse torque (PRT) in a dynamic compression plate-screw construct used in a goat tibia segmental defect model

Background Peak reverse torque (PRT) is a valid method to evaluate implants' secondary stability in the healing bone. The secondary stability is achieved by the implant over time and it has been positively correlated with the implants' osseointegration level. In other words, peak reverse torque is the force required to break the bone-implant interface. The purpose of this study was to compare the peak reverse torque for the self-tapping and non-self-tapping screws used in a dynamic compression plate–screw–bone construct after 60 days of loading when used to stabilize 2.5-cm defects in the tibia of goats. The second objective was to compare the peak removal torque of the screws placed in the different positions to evaluate the impact of construct biomechanics on implants osseointegration. Results In total, 176 non-self-tapping screws and 66 self-tapping screws were used to fix the 8-holes dynamic compression plates to the bones. The screws were placed in the tibiae from proximal (position sites 1,2, 3) to distal (position sites 4,5,6) and were removed 60 days post-implantation. The animals remained weight-bearing throughout the study period. The screws placed in the proximal diaphysis had significantly less peak reverse torque than screws placed in the distal diaphysis in both groups (p &lt; 0.05). The peak reverse torque resistance was also significantly less for the non-self-tapping screws as compared with the self-tapping screws (p &lt; 0.05). The intracortical fractures in the trans-cortex occurred significantly more frequently during the placement of non-self-tapping screws (p &lt; 0.05) as compared with self-tapping screws (p &lt; 0.05). Conclusions Based on these results, we concluded that self-tapping screws may be expected to maintain a more stable bone-implant interface during the first 60 days of loading as compared with non-self-tapping screws. This should be a consideration for orthopedic surgeons and scientists using bone plates to stabilize non-load sharing fractures when a stable plate-screw-bone interface is needed to ensure prolonged stability.

opencc-zeroSep 2019View details →
dryad32/100

Data from: Biomechanical evaluation of peak reverse torque (PRT) in a dynamic compression plate-screw construct used in a goat tibia segmental defect model

Open the record for dataset details and reuse information.

publicSep 2019View details →
dryad28/100

Data from: Force and torque on spherical particles in micro-channel flows using computational fluid dynamics

To delineate the influence of hemodynamic force on cell adhesion processes, model in vitro fluidic assays that mimic physiological conditions are commonly employed. Herein, we offer a framework for solution of the three-dimensional Navier–Stokes equations using computational fluid dynamics (CFD) to estimate the forces resulting from fluid flow near a plane acting on a sphere that is either stationary or in free flow, and we compare these results to a widely used theoretical model that assumes Stokes flow with a constant shear rate. We find that while the full three-dimensional solutions using a parabolic velocity profile in CFD simulations yield similar translational velocities to those predicted by the theoretical method, the CFD approach results in approximately 50% larger rotational velocities over the wall shear stress range of 0.1–5.0 dynes cm−2. This leads to an approximately 25% difference in force and torque calculations between the two methods. When compared with experimental measurements of translational and rotational velocities of microspheres or cells perfused in microfluidic channels, the CFD simulations yield significantly less error. We propose that CFD modelling can provide better estimations of hemodynamic force levels acting on perfused microspheres and cells in flow fields through microfluidic devices used for cell adhesion dynamics analysis.

opencc-zeroDec 2015View details →
dryad28/100

Data from: Force and torque on spherical particles in micro-channel flows using computational fluid dynamics

Open the record for dataset details and reuse information.

publicJun 2016View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.