Skip to main content
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

47

datasets available to search

ShareScore release 0.7.1

Reset

Dataset results

47 results for “Expedition 367”

Learn how ShareScore rates datasets ↗
zenodo44/100

IODP Expedition 367 X-ray fluorescence (XRF)

Elemental peak intensities in section halves were measured by an Avaatech X-ray fluorescence (XRF) Core Scanner postexpedition. Each measurement position may be measured at multiple XRF conditions in order to excite and measure specific ranges of elements (e.g., 10 kV and no filter for light elements). Peak intensity changes (concentrations not provided) are then used to help recognize and define major chemostratigraphic units without the need for destructive sampling. Data are presented in comma-delimited (CSV) files by section and by energy/instrumental conditions.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Bulk Density (GRA)

Gamma ray attenuation (GRA) data were acquired using a Cs-137 collimated source and a sodium iodide (thallium), or NaI(Tl), scintillation detector. The signal was calibrated using water and aluminum standards to provide a proxy for bulk density. This measurement was performed by a sensor mounted on either the Whole-Round Multisensor Logger (WRMSL) or the Special Task Multisensor Logger (STMSL); which track was used for a given data set is indicated in the data.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Carbonates composite report

This composite report includes data from two analyses (total carbon from Elemental analysis [CHNS], and inorganic carbon from [Coulometer]). Each row combines the CHNS and Coulometer data from measurements made on the same sample at the same time for a particular section and section offset (depth). If data do not exist for a particular expedition, the column does not appear. To identify individual samples and tests, see each separate data type (Elemental analysis and Coulometer). If the same sample was measured multiple times by any of the methods, results in the report will be combined on one line where possible. Each additional replicate result will be shown in subsequent rows and will be combined where possible. Report includes results for carbon forms: total, inorganic, calcium carbonate, and organic by difference, along with total hydrogen, nitrogen, and sulfur.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Whole-round core section composite 360 degree images

Images of the outside of hard rock whole-round sections were acquired using a linescan imager (Section Half Imaging Logger [SHIL]) and a special holder that allows each 90 degree segment of the outer surface to be positioned properly. The images were taken at a resolution of 20 lines/mm (50 micropixels). JRSO staff take these quadrant images and compile them into a side-by-side rollout photograph of the section. Composite images are available as both JPG and TIF image formats. Individual quadrant images are available as JPG images only through this report; contact the <a href="mailto:database@iodp.tamu.edu">IODP-JRSO Data Librarian</a> if quadrant TIF files (~160 MB) are needed.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Thin section images

Hard rock and sediment thin section images were acquired using either the JRSO-developed Petrographic Image Capture and Archival Tool (PICAT) imager or (rarely) an upright microscope and a digital camera. Sample images are acquired in unpolarized, polarized, and/or cross-polarized light. Image files are presented compressed by hole.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Titration

Various chemical constituents (most commonly chloride) were measured by titration using either an autotitrator (chloride) or a manual titrator (other compounds). Chloride was measured by ion-selective electrode and a silver nitrate titration until all chloride is bound as silver chloride.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Thermal conductivity

Thermal conductivity was measured using the heated needle method in either full-space needle configuration (soft/saturated sediments) or half-space needle configuration (harder materials) of a TeKa Berlin TK-04 thermal conductivity meter. Heat is applied to the sample and then thermal equilibrium is sought. The heating and equilibration curve is reduced to derive the thermal conductivity value. Raw data are stored if a user wishes to do off-line or postexpedition reduction.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Magnetic remanence (SRM-longcore)

Magnetic remanence was measured on section halves (and rarely on whole-round sections) using a 2G Enterprises 760R cryogenic magnetometer, first as natural remanent magnetization (NRM) and then after demagnetization steps were performed on the samples by alternating field (AF) demagnetizer coils mounted in-line within the instrument.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Magnetic remanence (spinner)

Magnetic remanence was measured on discrete samples by an Agico JR-6A spinner magnetometer, first as natural remanent magnetization (NRM) and then after demagnetization or remagnetization steps were performed on the samples (e.g., alternating field [AF] demagnetization, thermal demagnetization [TD], or isothermal remanent magnetization [IRM]).

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Closeup images

Close-up images taken by digital cameras as requested by the science party, typically when the section-half image is not sufficient. Close-up photographs of the areas of interest may be taken from whole-round sections, pieces, or section halves in sediments and rock.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Alkalinity and pH

Alkalinity was determined by Gran titration with an autotitrator (Metrohm 794 basic Titrino) using 0.1 M HCl at 20 degrees C. Report includes alkalinity, correction factor (if applicable), and pH.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Scanning electron microscope images

Microscopic images of discrete samples were acquired using a scanning electron microscope (SEM) and captured as image files. These files were uploaded along with a brief description and a record of the microscopic conditions when the image was taken.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Whole-round core section images

Images of the outside of hard rock whole-round sections were acquired using a linescan imager (Section Half Imaging Logger [SHIL]) and a special holder that allows each 90 degree segment of the outer surface to be positioned properly. The images were taken at a resolution of 20 lines/mm (50 micropixels). JRSO staff take these quadrant images and compile them into a side-by-side rollout photograph of the section. Composite images are available as both JPG and TIF image formats. Individual quadrant images are available as JPG images only through this report; contact the <a href="mailto:database@iodp.tamu.edu">IODP-JRSO Data Librarian</a> if quadrant TIF files (~160 MB) are needed.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Magnetic remanence (SRM-discrete)

Raw data files for the magnetic remanence measurements of discrete and section-half samples on the superconducting rock magnetometer (SRM-DISC and SRM-SECT) are stored on by hole and by expedition, and are designated as discrete samples, section halves, or, rarely, whole-round sections.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Spectrophotometry

Interstitial water constitutents were measured by UV-VIS spectrometry using colorimetric methods (e.g., ammonium, nitrate, nitrite, phosphate, silica, and sulfide) by an Agilent CARY 100 UV-VIS spectrophotometer.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Sample report

Report includes detailed information about samples taken for testing: location/depth, type/form factor, test, request number, and database identifier.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Color reflectance

Color reflectance data were measured on section halves using an integration sphere and a UV-VIS spectrophotometer mounted on the Section Half Multisensor Logger (SHMSL). Spectral counts are recorded in the range of 380 to 700 nm, covering the visible spectrum, and binned in ~2 nm bins. Spectral data are reduced from spectra and recorded in tristimulus XYZ values, CieLAB L*a*b* values, and other units.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 Section summary

Report includes data for individual core sections: coring/drilling depths and recovery, database identifiers for the whole section and section halves, and number of samples taken from the section before and after splitting.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 P-wave velocity logger (whole round)

P-wave velocity data were measured on whole-round sections on the Whole-Round Multisensor Logger (WRMSL) using pairs of piezoelectric transducers mounted on a caliper system. Measurements may be affected by degassing of pore fluid and microfracturing during core recovery. Report includes P-wave velocity in x-y plane and distance and traveltime between transducers.

opencc-by-4.0Sep 2018View details →
zenodo44/100

IODP Expedition 367 P-wave velocity caliper (section)

P-wave velocity data were measured on undisturbed section halves (JRSO-defined x-axis) and/or discrete cube and cylinder samples (x, y, or z-axis) using pairs of piezoelectric transducers mounted on a caliper system. Report includes P-wave velocity in x, y, and/or z-direction, caliper separation, traveltime between transucers, and first arrival picks.

opencc-by-4.0Sep 2018View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record