Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
46
datasets available to search
ShareScore release 0.7.1
Dataset results
46 results for “Expedition 391”
IODP Expedition 391 Alkalinity and pH
Alkalinity was determined by Gran titration with an autotitrator (Metrohm 794 basic Titrino) using 0.1 M HCl at 20 degrees C. Report includes alkalinity, correction factor (if applicable), and pH.
IODP Expedition 391 Thin section images
Hard rock and sediment thin section images were acquired using either the JRSO-developed Petrographic Image Capture and Archival Tool (PICAT) imager or (rarely) an upright microscope and a digital camera. Sample images are acquired in unpolarized, polarized, and/or cross-polarized light. Image files are presented compressed by hole.
IODP Expedition 391 Section summary
Report includes data for individual core sections: coring/drilling depths and recovery, database identifiers for the whole section and section halves, and number of samples taken from the section before and after splitting.
IODP Expedition 391 Photomicrographs
Microscopic images of discrete samples were acquired using stereo and upright light microscopes and captured on digital cameras. Image files were uploaded along with a brief description and a record of the microscopic and lighting conditions when the image was taken.
IODP Expedition 391 Whole-round core section composite 360 degree images
Images of the outside of hard rock whole-round sections were acquired using a linescan imager (Section Half Imaging Logger [SHIL]) and a special holder that allows each 90 degree segment of the outer surface to be positioned properly. The images were taken at a resolution of 20 lines/mm (50 micropixels). JRSO staff take these quadrant images and compile them into a side-by-side rollout photograph of the section. Composite images are available as both JPG and TIF image formats. Individual quadrant images are available as JPG images only through this report; contact the <a href="mailto:database@iodp.tamu.edu">IODP-JRSO Data Librarian</a> if quadrant TIF files (~160 MB) are needed.
IODP Expedition 391 Carbonates composite report
This composite report includes data from two analyses (total carbon from Elemental analysis [CHNS], and inorganic carbon from [Coulometer]). Each row combines the CHNS and Coulometer data from measurements made on the same sample at the same time for a particular section and section offset (depth). If data do not exist for a particular expedition, the column does not appear. To identify individual samples and tests, see each separate data type (Elemental analysis and Coulometer). If the same sample was measured multiple times by any of the methods, results in the report will be combined on one line where possible. Each additional replicate result will be shown in subsequent rows and will be combined where possible. Report includes results for carbon forms: total, inorganic, calcium carbonate, and organic by difference, along with total hydrogen, nitrogen, and sulfur.
IODP Expedition 391 Inorganic carbon (coulometer)
Inorganic carbon (carbonate) is determined by coulometry, which uses a photodetection cell to measure carbon dioxide evolved during sample acidification. Report includes percent inorganic carbon and calcium carbonate.
IODP Expedition 391 Gas safety report
This composite report returns data from two different gas chromatograph configurations (GC3 and NGA). Each row combines data from several measurements made on the same sample at the same time for a particular headspace or vacutainer sample. If data do not exist for a particular expedition, the column does not appear. Gas samples were measured by gas chromatography and either flame ionization detection (GC-FID) or thermal conductivity detection (GC-TCD). Reported analytes may include methane, ethane, ethene, propane, propene, n-butane, i-butane, n-pentane, i-pentane, n-hexane, i-hexane, n-heptane, i-heptane, nitrogen, oxygen, carbon monoxide, carbon dioxide, and hydrogen sulfide. When data are available, methane to (ethane + ethene) ratio (C<sub>1</sub>/C<sub>2</sub>�ratio) is reported. To identify individual samples and tests, see each separate analysis (GC3, NGAFID, and/or NGATCD).
IODP Expedition 391 Micropaleontology
Paleontological data were collected using microscopes and recorded in the JRSO description software. All data for a species group (e.g., diatoms or nannofossils) were collected in a Microsoft Excel worksheet by hole. A zip file of the entire expedition's observations is also available.
IODP Expedition 391 Visual core description
Descriptions of samples, generally at the section half and smear slide or thin section scale, were performed by shipboard scientists and recorded in the JRSO description software. Descriptive data for both macroscopic and microscopic examination were collected in a Microscoft Excel workbook by hole. A zip file of the entire expedition's observations is also available.
IODP Expedition 391 Closeup images
Close-up images taken by digital cameras as requested by the science party, typically when the section-half image is not sufficient. Close-up photographs of the areas of interest may be taken from whole-round sections, pieces, or section halves in sediments and rock.
IODP Expedition 391 Bulk Density (GRA)
Gamma ray attenuation (GRA) data were acquired using a Cs-137 collimated source and a sodium iodide (thallium), or NaI(Tl), scintillation detector. The signal was calibrated using water and aluminum standards to provide a proxy for bulk density. This measurement was performed by a sensor mounted on either the Whole-Round Multisensor Logger (WRMSL) or the Special Task Multisensor Logger (STMSL); which track was used for a given data set is indicated in the data.
IODP Expedition 391 ICP-AES elemental analysis (solids)
Elemental contents in hard rock and sediment samples was measured by inductively coupled plasma - atomic emission spectrocopy (ICP-AES). Data are presented by element-wavelength pair (e.g., more than one calcium line may be reported). Elemental lines for which data do not exist for a particular expedition will not appear.
IODP Expedition 391 Interstitial water composite report
This composite report includes data from numerous interstitial water (IW) analyses (e.g., ICP-LIQUIDS and IONCHROM) in a variable set of columns. Each row combines the data from several tests (groups of measurements made on the same sample at the same time) for a particular IW sample. If data do not exist for a particular expedition, the column does not appear. To identify individual samples and tests, see each separate analysis (ALKALINITY, ICP-LIQUIDS, IONCHROM, SALINITY, SPEC, TITRATOR, and potentially others). Major and minor elements were determined by inductively coupled plasma-atomic emission spectrocsopy (ICP-LIQUIDS). Cations and anions were measured by ion chromatography (IONCHROM). Complex ions were measured by colorimetric measurements using a UV-VIS spectrometer (SPEC). Alkalinity and chloride was measured by titration (ALKALINITY and TITRATOR). Dissolved carbon (DC), dissolved inorganic carbon (DIC), and dissolved organic carbon (DOC) were measured by combustion in a total organic carbon (TOC) analyzer. Salinity was measured by refractometer (SALINITY). pH was measured by ion-selective electrode as part of the alkalinity procedure and is reported in the ALKALINITY analysis.
IODP Expedition 391 Ion chromatography
Cation and anion concentration in interstitial water samples was measured by ion chromatography using a conductivity detector. Cation analytes include calcium, magnesium, potassium, and sodium. Anion analytes include chloride, sulfate, and bromide.
IODP Expedition 391 Magnetic susceptibility (whole round)
Magnetic susceptibility was measured on whole-round sections (and rarely section halves) on the Whole-Round Multisensor Logger (WRMSL) and/or Special Task Multisensor Logger (STMSL) using a Bartington MS2 meter and a 90 mm or 80 mm MS2C loop. As volume of the sample is not controlled for this experiment, susceptibility units are recorded in instrument units and are not volume-corrected.
IODP Expedition 391 Moisture and Density
Moisture and density (MAD) data were acquired on ~10 mL sediment or rock samples by measuring three out of four material parameters: wet (saturated) mass, wet volume, dry mass, and/or dry volume after 24 h drying in a convection oven at 105 degrees C. From the moisture and volume measurements, the following phase relationships are calculated: wet and dry water content, wet bulk density, dry bulk density, grain density, porosity, and void ratio. The combination of measurements is defined by the submethod chosen: A, B, C, or D. Wet (A, B, or C) and dry (A, B, C, or D) mass is determined using motion-compensated balances. Wet volume is determined either by helium pycnometry (A) or by the sample's geometric dimensions using calipers (A or D). Dry volume (C or D) is measured by helium pycnometry. Submethods A and B are not recommended by IODP. Submethod C is suitable for saturated materials such as fine-grained sediments. Submethod D is suitable for unsaturated porous material such as certain limestones and basalts.
IODP Expedition 391 Core composite images
A digital composite image (PNG) is made for each core comprising core sections scanned using a line-scan camera. The composite layout is equivalent to traditional core table photos. Top left is top of core; color and meter rule references are included.
IODP Expedition 391 Magnetic susceptibility (Kappabridge)
Bulk magnetic susceptibility and anisotropy of magnetic susceptibility (AMS) were measured on discrete samples using an Agico KLY-4 Kappabridge susceptibility meter. Report includes individual and average principal susceptibilities, inclination and declination of principal susceptibilities, and volume-corrected bulk susceptibility.
IODP Expedition 391 Natural gamma radiation
Natural gamma radiation (NGR) data in the ~0.1 to 3.0 MeV range were measured using eight custom-designed sodium iodide (thallium) [NaI(Tl)] detectors arranged along the core measurement axis at 20 cm intervals. The NGR system uses layers of passive shielding (lead) and active shielding (plastic scintillators and coincidence electronics) to reduce the cosmic-ray signal for low-count analysis of sediment core sections and to obtain the maximum signal-to-noise ratio. Data are reported on a total counts per second basis and the raw spectral files are available as compressed files for later analysis.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.