Skip to main content
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

7

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

7 results for “Fast Fourier Transform”

Learn how ShareScore rates datasets ↗
zenodo40/100

Data for figures in "Reproducibility in Benchmarking Parallel Fast Fourier Transform based Applications"

<p>FFT benchmark data and Python plotting programs</p>

opencc-by-4.0Feb 2019View details →
zenodo36/100

Dataset_Multiscale Fast Fourier Transform homogenization of additively manufactured fiber reinforced composites from component-wise description of morphology

<p>Original micro-CT&nbsp;imaging data and output of processing via the OpenFiberSeg software of additively manufactured carbon fiber reinforced composites.&nbsp;</p> <p>This dataset accompanies the publication in Composite Science and Technology available at&nbsp;https://doi.org/10.1016/j.compscitech.2023.110261</p> <p>&nbsp;</p>

opencc-by-4.0Dec 2022View details →
nasa12/100

THEMIS-A: On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements, for particle and wave burst survey modes.

On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements for particle and wave burst survey modes. Spectra are produced only in Particle Burst and Wave Burst modes; only a preselected four of the signals listed in Table 1 are input at any time. Data fed through the FFT while not in Particle or Wave Burst modes is automatically disgarded. The FFTs (Cooley-Tukey algorithm) are conducted as an integral part of the power spectrum calculation by the Field Programable Gate Arrays (FPGAs). A CORDIC algorithm is used for sine/cosine calculations. The data has raw resolution of 1024 pts for 8,192 sample/sec signals and 2048 pts for 16,384 sample/sec signals (EAC measurements only). Signals at 8,192 samples/sec are handled by 1024-point FFTs, while those at 16,384 samples/sec go through 2048-point FFTs. Past and current signal configurations for specific spacecraft are listed bellow in Table 2. The spectra are arranged into log spaced frequency bins in steps of 16, 32, or 64. Cadence is adjusted to keep packet size constant (i.e. increasing the fequency resolution by a factor of 2 decreases the sampling rate by 1/2). The frequency bins cover a range of 0 Hz to 4 kHz. Table 1: FFT Input Signals. Signal Description SCMX, SCMY, SCMZ: Three axis magnetic fiend from SCM V1 through V6: Probe-spacecraft voltage for all six EFI sensors E12DC, E34DC, E56DC: DC-coupled electric field measured from opposing EFI sensors E12AC, E34AV, E56AC: AC-coupled electric field measured from opposing EFI sensors E12HF: High frequency electric field from EFI Table 2: Spacecraft specific configurations. All probes were initially set to use EDC34, EDC56, SCM2, and SCM3 signals for both particle and wave burst modes. Output was set to 16 frequency bins at 4 Hz. Configuration Changes: 9 June 2008: Particle burst spectra resolution increased from 16 to 64 bins and cadence slowed from 4 Hz to 1 Hz for closer analysis of spectral features. N/A: Particle burst spectra on all probes reconfigured to 64 bins at 1 Hz. 15 Aug 2008: E34DC and E56DC inputs switched to E34AC and E56AC to reduce impact of wake fields on FFT spectral measurements. 15 Oct 2008: Particle burst spectra resolution reduced from 64 to 32 bins and the rate increased from 1 Hz to 2 Hz; a response to noise from plasma wake fields in the 64 bin spectra. Table 3: Instrument-Spacecraft Physical Configuration Instrument Alignment in Spacecraft Geometric coordinates (SPG). See THEMIS website for coordinate system details and mechanical drawings. EFI boom 1: Along positive X-axis EFI boom 2: Along negative X-axis EFI boom 3: Along positive Y-axis EFI boom 4: Along negative Y-axis EFI boom 5: Along positive Z-axis EFI boom 6: Along negative Z-axis SCM *The SCM uses an instrument specific set of axes; an orthogonal system centered instrument with the X-axis 12.1 degrees from the SPG X-axis.

restrictednotspecifiedAug 2025View details →
nasa12/100

THEMIS-B: On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements, for particle and wave burst survey modes.

On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements for particle and wave burst survey modes. Spectra are produced only in Particle Burst and Wave Burst modes; only a preselected four of the signals listed in Table 1 are input at any time. Data fed through the FFT while not in Particle or Wave Burst modes is automatically disgarded. The FFTs (Cooley-Tukey algorithm) are conducted as an integral part of the power spectrum calculation by the Field Programable Gate Arrays (FPGAs). A CORDIC algorithm is used for sine/cosine calculations. The data has raw resolution of 1024 pts for 8,192 sample/sec signals and 2048 pts for 16,384 sample/sec signals (EAC measurements only). Signals at 8,192 samples/sec are handled by 1024-point FFTs, while those at 16,384 samples/sec go through 2048-point FFTs. Past and current signal configurations for specific spacecraft are listed bellow in Table 2. The spectra are arranged into log spaced frequency bins in steps of 16, 32, or 64. Cadence is adjusted to keep packet size constant (i.e. increasing the fequency resolution by a factor of 2 decreases the sampling rate by 1/2). The frequency bins cover a range of 0 Hz to 4 kHz. Table 1: FFT Input Signals. Signal Description SCMX, SCMY, SCMZ: Three axis magnetic fiend from SCM V1 through V6: Probe-spacecraft voltage for all six EFI sensors E12DC, E34DC, E56DC: DC-coupled electric field measured from opposing EFI sensors E12AC, E34AV, E56AC: AC-coupled electric field measured from opposing EFI sensors E12HF: High frequency electric field from EFI Table 2: Spacecraft specific configurations. All probes were initially set to use EDC34, EDC56, SCM2, and SCM3 signals for both particle and wave burst modes. Output was set to 16 frequency bins at 4 Hz. Configuration Changes: 30 June - 3 July 2008: Particle burst spectra on all probes reconfigured to 64 bins at 1 Hz. Table 3: Instrument-Spacecraft Physical Configuration Instrument Alignment in Spacecraft Geometric coordinates (SPG). See THEMIS website for coordinate system details and mechanical drawings. EFI boom 1: Along positive X-axis EFI boom 2: Along negative X-axis EFI boom 3: Along positive Y-axis EFI boom 4: Along negative Y-axis EFI boom 5: Along positive Z-axis EFI boom 6: Along negative Z-axis SCM: *The SCM uses an instrument specific set of axes; an orthogonal system centered instrument with the X-axis 12.1 degrees from the SPG X-axis.

restrictednotspecifiedAug 2025View details →
nasa12/100

THEMIS-D: On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements, for particle and wave burst survey modes.

On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements for particle and wave burst survey modes. Spectra are produced only in Particle Burst and Wave Burst modes; only a preselected four of the signals listed in Table 1 are input at any time. Data fed through the FFT while not in Particle or Wave Burst modes is automatically disgarded. The FFTs (Cooley-Tukey algorithm) are conducted as an integral part of the power spectrum calculation by the Field Programable Gate Arrays (FPGAs). A CORDIC algorithm is used for sine/cosine calculations. The data has raw resolution of 1024 pts for 8,192 sample/sec signals and 2048 pts for 16,384 sample/sec signals (EAC measurements only). Signals at 8,192 samples/sec are handled by 1024-point FFTs, while those at 16,384 samples/sec go through 2048-point FFTs. Past and current signal configurations for specific spacecraft are listed bellow in Table 2. The spectra are arranged into log spaced frequency bins in steps of 16, 32, or 64. Cadence is adjusted to keep packet size constant (i.e. increasing the fequency resolution by a factor of 2 decreases the sampling rate by 1/2). The frequency bins cover a range of 0 Hz to 4 kHz. Table 1: FFT Input Signals. Signal Description SCMX, SCMY, SCMZ: Three axis magnetic fiend from SCM V1 through V6: Probe-spacecraft voltage for all six EFI sensors E12DC, E34DC, E56DC: DC-coupled electric field measured from opposing EFI sensors E12AC, E34AV, E56AC: AC-coupled electric field measured from opposing EFI sensors E12HF: High frequency electric field from EFI Table 2: Spacecraft specific configurations. All probes were initially set to use EDC34, EDC56, SCM2, and SCM3 signals for both particle and wave burst modes. Output was set to 16 frequency bins at 4 Hz. Configuration Changes: 23-27 June 2008: Particle burst spectra on all probes reconfigured to 64 bins at 1 Hz. Table 3: Instrument-Spacecraft Physical Configuration Instrument Alignment in Spacecraft Geometric coordinates (SPG). See THEMIS website for coordinate system details and mechanical drawings. EFI boom 1: Along positive X-axis EFI boom 2: Along negative X-axis EFI boom 3: Along positive Y-axis EFI boom 4: Along negative Y-axis EFI boom 5: Along positive Z-axis EFI boom 6: Along negative Z-axis SCM *The SCM uses an instrument specific set of axes; an orthogonal system centered instrument with the X-axis 12.1 degrees from the SPG X-axis.

restrictednotspecifiedAug 2025View details →
nasa12/100

THEMIS-C: On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements, for particle and wave burst survey modes.

On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements for particle and wave burst survey modes. Spectra are produced only in Particle Burst and Wave Burst modes; only a preselected four of the signals listed in Table 1 are input at any time. Data fed through the FFT while not in Particle or Wave Burst modes is automatically disgarded. The FFTs (Cooley-Tukey algorithm) are conducted as an integral part of the power spectrum calculation by the Field Programable Gate Arrays (FPGAs). A CORDIC algorithm is used for sine/cosine calculations. The data has raw resolution of 1024 pts for 8,192 sample/sec signals and 2048 pts for 16,384 sample/sec signals (EAC measurements only). Signals at 8,192 samples/sec are handled by 1024-point FFTs, while those at 16,384 samples/sec go through 2048-point FFTs. Past and current signal configurations for specific spacecraft are listed bellow in Table 2. The spectra are arranged into log spaced frequency bins in steps of 16, 32, or 64. Cadence is adjusted to keep packet size constant (i.e. increasing the fequency resolution by a factor of 2 decreases the sampling rate by 1/2). The frequency bins cover a range of 0 Hz to 4 kHz. Table 1: FFT Input Signals. Signal Description SCMX, SCMY, SCMZ: Three axis magnetic fiend from SCM V1 through V6: Probe-spacecraft voltage for all six EFI sensors E12DC, E34DC, E56DC: DC-coupled electric field measured from opposing EFI sensors E12AC, E34AV, E56AC: AC-coupled electric field measured from opposing EFI sensors E12HF: High frequency electric field from EFI Table 2: Spacecraft specific configurations. All probes were initially set to use EDC34, EDC56, SCM2, and SCM3 signals for both particle and wave burst modes. Output was set to 16 frequency bins at 4 Hz. Configuration Changes: 30 June - 3 July 2008: Particle burst spectra on all probes reconfigured to 64 bins at 1 Hz. Table 3: Instrument-Spacecraft Physical Configuration Instrument Alignment in Spacecraft Geometric coordinates (SPG). See THEMIS website for coordinate system details and mechanical drawings. EFI boom 1: Along positive X-axis EFI boom 2: Along negative X-axis EFI boom 3: Along positive Y-axis EFI boom 4: Along negative Y-axis EFI boom 5: Along positive Z-axis EFI boom 6: Along negative Z-axis SCM: *The SCM uses an instrument specific set of axes; an orthogonal system centered instrument with the X-axis 12.1 degrees from the SPG X-axis.

restrictednotspecifiedAug 2025View details →
nasa12/100

THEMIS-E: On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements, for particle and wave burst survey modes.

On Board Fast Fourier Transform (FFT) power spectra of Electric (EFI) and Magnetic (SCM) field measurements for particle and wave burst survey modes. Spectra are produced only in Particle Burst and Wave Burst modes; only a preselected four of the signals listed in Table 1 are input at any time. Data fed through the FFT while not in Particle or Wave Burst modes is automatically disgarded. The FFTs (Cooley-Tukey algorithm) are conducted as an integral part of the power spectrum calculation by the Field Programable Gate Arrays (FPGAs). A CORDIC algorithm is used for sine/cosine calculations. The data has raw resolution of 1024 pts for 8,192 sample/sec signals and 2048 pts for 16,384 sample/sec signals (EAC measurements only). Signals at 8,192 samples/sec are handled by 1024-point FFTs, while those at 16,384 samples/sec go through 2048-point FFTs. Past and current signal configurations for specific spacecraft are listed bellow in Table 2. The spectra are arranged into log spaced frequency bins in steps of 16, 32, or 64. Cadence is adjusted to keep packet size constant (i.e. increasing the fequency resolution by a factor of 2 decreases the sampling rate by 1/2). The frequency bins cover a range of 0 Hz to 4 kHz. Table 1: FFT Input Signals. Signal Description SCMX, SCMY, SCMZ: Three axis magnetic fiend from SCM V1 through V6: Probe-spacecraft voltage for all six EFI sensors E12DC, E34DC, E56DC: DC-coupled electric field measured from opposing EFI sensors E12AC, E34AV, E56AC: AC-coupled electric field measured from opposing EFI sensors E12HF: High frequency electric field from EFI Table 2: Spacecraft specific configurations. All probes were initially set to use EDC34, EDC56, SCM2, and SCM3 signals for both particle and wave burst modes. Output was set to 16 frequency bins at 4 Hz. Configuration Changes: 23-27 June 2008: Particle burst spectra on all probes reconfigured to 64 bins at 1 Hz. Table 3: Instrument-Spacecraft Physical Configuration Instrument Alignment in Spacecraft Geometric coordinates (SPG). See THEMIS website for coordinate system details and mechanical drawings. EFI boom 1: Along positive X-axis EFI boom 2: Along negative X-axis EFI boom 3: Along positive Y-axis EFI boom 4: Along negative Y-axis EFI boom 5: Along positive Z-axis EFI boom 6: Along negative Z-axis SCM: *The SCM uses an instrument specific set of axes; an orthogonal system centered instrument with the X-axis 12.1 degrees from the SPG X-axis.

restrictednotspecifiedAug 2025View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record