Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
18
datasets available to search
ShareScore release 0.9.0
Dataset results
18 results for “Fourier transform infrared”
Fourier-transform Infrared (FT-IR) spectroscopy fingerprints subpopulations of extracellular vesicles of different sizes and cellular origin
<p>Atomic Force Microscopy images of Large (LEV), Medium (MEV) and Small (SEV) Extrzcellular vesicles (EVs) from murine cell line B16 (B16-F10, ATCC CRL-647; Mus musculus, mouse; tissue: melanoma skin). Image size 8.3 x 8.3 um. Analysis mode: Tapping mode in air as described in Paolini et al. https://doi.org/10.1080/20013078.2020.1741174</p>
Rapid assessment of lipidomics sample quality and quantity using attenuated total reflectance Fourier-transform infrared spectroscopy
<p>In this work, we aimed to develop a simple lipid quality and quantification method for biological lipid extracts, as a step in lipidomics workflows, with minimal sample requirement. We chose FTIR spectroscopy with an Attenuate Total Reflectance (ATR) sampling method as it requires just 1 microliter of MS-ready sample without additional sample preparation. We validated the proposed lipidomics sample quality control workflow using a set of plasma samples (n=107, with 3-4 technical replicates) with comparison to LC-MS-based lipidomics. The following file contains the resulting spectra acquired by ATR-FTIR spectrometry for these plasma samples, standard curves and contaminated samples used for method development. Spectrometer was ambient blanked and detector cleaned between each measurement. Lipid samples were extracted by butanol-methanol (3:1) precipitation, and dried directly onto the ATR-FTIR detector. Absorbance was measured between 4,000 and 650 cm-1 wavenumbers, at a resolution of 8cm-1. Each spectra has been baseline corrected (whole spectra).</p>
Fourier transformed infrared reflectance (FTIR) spectra of peat soils collected from the top and bottom of peatland erosion gullies
<p>Peat soil was randomly collected from gullies within two eroding blanket bogs. Balmoral (BAM) is on a large high-altitude plateau blanket bog in the eastern part of the Cairngorms National Park, Scotland, UK (56.93° N, − 3.16° E, 642 m asl) and Glensaugh (GSA) is an upland livestock farm with sections of and blanket bog peatland in the Grampian foothills (56.55° N, 2.33° E, 412 m asl). Both sites have undergone extensive degradation and peat erosion, and both have, in some parts, recently undergone restoration practices, including bunding and reprofiling.</p> <p>Peat samples were collected at Glensaugh and Balmoral as follows. At Glensaugh, peat at the top 1 cm of exposed gully sides (approximately 10-20cm from the vegetated surface) and at the gully bottom were taken, air dried and passed on for FTIR analysis. These gullies correspond to four erosion pin measurement areas and their corresponding peat sediment trap areas at Glensaugh. At Balmoral, the same approach was taken except six ‘gully top’ and ‘gully bottom’ sites were randomly selected and not geographically paired in the same way at Glensaugh.</p> <p>Samples were air dried and finely ball milled, prior to FTIR analysis. FTIR spectra were recorded using a Bruker Vertex 70 FTIR spectrometer (Bruker, Ettlingen, Germany) and OPUS 7.2 software. To record the FTIR spectra, each of the samples were placed, in turn, on a Diamond Attenuated Total Reflectance (DATR) sampling accessory, with a single reflectance system. Data points in the range of 4000-400 cm-1 were recorded with a resolution of 4 cm-1 and average of 64 scans. A spectrum of the empty sampling accessory, with the same resolution and number of scans, was recorded as the background spectrum before each measurement. </p> <p>Since the penetration depth for the DATR accessory is different for each wavelength and is directly proportional to the wavelength of the incident light (The higher the wavenumber the lower the penetration), an ATR correction was applied to the spectra to correct this effect, using the OPUS software. No correction was required for water vapour and CO2 as the spectrometer is continuously purged with dry air.</p> <p> </p> <p>In the dataset, columns correspond to the following:</p> <p>Site: Balmoral or Glensaugh</p> <p>Gully Position: Top or bottom</p> <p>Gully Number: Replicate gullies within the site</p> <p>Sample date: Date</p> <p>Sample ID: Unique identifier</p> <p>Remaining columns: Reflectance at a given wavelength</p>
Fourier transform infrared spectroscopy as a non-destructive method for analysing herbarium specimens
<p>Dried plant specimens stored in herbaria are an untapped treasure chest of information on environmental conditions, plant evolution and change over many hundreds of years. Due to their delicate nature and irreplaceability, there is limited access for analysis to these sensitive samples, particularly where chemical data is obtained using destructive techniques. Fourier transform infrared spectroscopy (FTIR) is a chemical analysis technique that can be applied non-destructively to understand chemical bonding information and therefore functional groups within the sample. This provides the potential for understanding geographic, spatial and species-specific variation in plant biochemistry. Here we demonstrate the use of mid-FTIR microspectroscopy for the analysis of <em>Drosera</em> <em>rotundifolia</em> herbaria specimens, which were collected 100 years apart from different locations. Principal component and hierarchical clustering analysis enabled successful differentiation between three main regions on the plant (lamina, tentacle stalk and tentacle head), and between the different specimens. Lipids and protein spectral regions were particularly sensitive differentiators of plant tissues. Differences between the different sets of specimens were smaller. This study demonstrates that relevant information can be extracted from herbarium specimens using FTIR, with little impact on the specimens. FTIR therefore provides the potential as a powerful tool to unlock historic information within herbaria.</p>
Fourier-transformed infrared (FTIR) spectra of the paper "Untangling the role of biotic and abiotic ageing of various environmental plastics toward the sorption of metals"
<p>The dataset include Fourier-transformed infrared (FTIR) spectra of UV aged and biofouled environmental plastics, used for the publication "Untangling the role of biotic and abiotic ageing of various environmental plastics toward the sorption of metals" (the paper is available at the following link: <a href="https://doi.org/10.1016/j.scitotenv.2023.164807">https://doi.org/10.1016/j.scitotenv.2023.164807</a>).</p> <p>The dataset is organized as follows:</p> <p>-All samples contains metadata considering polymer type (polylactic acid (PLA), polypropylene (PP), and polyethylene (PE)), the type of ageing treatment (UV ageing, biofouling and UV ageing-biofouling), the amount of time (in hours) of treatment and the number of replicate sample analyzed.</p> <p>-for every sample the raw data (scaled for the maximum absorbance value) of the FT-IR spectrum is given.</p> <p>Further experimental details are listed in the manuscript text.</p>
Data from: Stability assessment of organic sulfur and organosulfate compounds in filter samples for quantification by Fourier Transform-Infrared Spectroscopy and Ion Chromatography
Open the record for dataset details and reuse information.
Time and spatially-resolved Fourier-Transform Infrared (FTIR) Spectromicroscopy of cellulose in buffered reactions with Trichoderma reesei Cel7A
Open the record for dataset details and reuse information.
Fourier transform infrared spectroscopy as a non-destructive method for analysing herbarium specimens
Open the record for dataset details and reuse information.
FTIR-Plastics: a Fourier Transform Infrared Spectroscopy dataset for the six most prevalent industrial plastic polymers.
<p><span><span>Two datasets are presented: FTIR-Plastics-C4 and FTIR-Plastics-C8, comprising 6,000 spectra obtained through Fourier Transform Infrared Spectroscopy (FTIR) applied to the six most used synthetic polymers: Polyethylene Terephthalate (PET), High-Density Polyethylene (HDPE), Polyvinyl Chloride (PVC), Low-Density Polyethylene (LDPE), Polypropylene (PP), and Polystyrene (PS). The key feature of the datasets lies in the FTIR analysis, which reports the percentage transmittance as the intensity measure as a function of the wavelength of an Infrared light source, expressed as wavenumber (with units in cm</span></span><sup><span><span>-1</span></span></sup><span><span>). FTIR analysis was performed using a Jasco FTIR PRO 4x spectrophotometer with a wavenumber resolution setting of 8 cm</span></span><sup><span><span>-1</span></span></sup><span><span> for FTIR-Plastics-C8 and 4 cm</span></span><sup><span><span>-1</span></span></sup><span><span> for FTIR-Plastics-C4, both employing a configuration of 32 scans and a range from 4000 to 400 cm</span></span><sup><span><span>-1</span></span></sup><span><span>. The datasets are presented in CSV (comma-separated values) format, including the following information (per each column):</span></span></p> <ul> <li> <p><span><span><strong>IDE</strong></span></span><span><span>: unique identifier of the sample.</span></span></p> </li> <li> <p><span><span><strong>Polymer: </strong></span></span><span><span>type of synthetic polymer (PET, HDPE, PVC, LDPE, PP, or PS).</span></span></p> </li> <li> <p><span><span><strong>Technique: </strong></span></span><span><span>Type of technique used (FTIR).</span></span></p> </li> <li> <p><span><span><strong>Sample: </strong></span></span><span><span>polymer sample number.</span></span></p> </li> <li> <p><span><span><strong>BR</strong></span></span><span><span>: scanning configuration (32).</span></span></p> </li> <li> <p><span><span><strong>RST</strong></span></span><span><span>: resolution configuration (8 or 4 cm</span></span><sup><span><span>-1</span></span></sup><span><span>).</span></span></p> </li> <li> <p><span><span><strong>Data (x) y Data(y): </strong></span></span><span><span>1884 pairs of columns for FTIR-Plastics-C8 and 3751 pairs of columns for FTIR-Plastics-C4, representing values on the "x" axis (wavenumber) and the "y" axis values associated with molecular vibration intensities, indicating the transmittance (%), which differentiates each polymer.</span></span></p> </li> </ul> <p><span><span>Additionally, the files generated by the Jasco spectrophotometer for each polymer are provided, which were standardized by adding a header with the following structure:</span></span></p> <ul> <li> <p><span><span>TITLE SAMPLE NAME: referring to the name of the analyzed polymer.</span></span></p> </li> <li> <p><span><span>DATA TYPE: specifying the characterization technique.</span></span></p> </li> <li> <p><span><span>MEASUREMENT INFORMATION: equipment used for data collection.</span></span></p> </li> <li> <p><span><span>MODEL NAME: name of the equipment used.</span></span></p> </li> <li> <p><span><span>SERIAL No: serial number assigned to the equipment used.</span></span></p> </li> <li> <p><span><span>ACCESSORY: complementary device integrated into the equipment.</span></span></p> </li> <li> <p><span><span>LIGHT SOURCE: standardized light source related to the DLATGS detector.</span></span></p> </li> <li> <p><span><span>RESOLUTION: parameters are used to distinguish the wavenumber in the analyzed materials.</span></span></p> </li> <li> <p><span><span>XUNIT/HORIZONTAL AXIS: referring to the unit’s title assigned on the x-axis.</span></span></p> </li> <li> <p><span><span>YUNITS/VERTICAL AXIS: referring to the unit’s title designated on the y-axis.</span></span></p> </li> <li> <p><span><span>FIRSTX: initial value set for the x-axis.</span></span></p> </li> <li> <p><span><span>FIRSTY: initial value set for the y-axis.</span></span></p> </li> <li> <p><span><span>LASTX: final value set for the x-axis.</span></span></p> </li> <li> <p><span><span>LASTY: final value set for the y-axis.</span></span></p> </li> <li> <p><span><span>NPOINTS: total data points in the file.</span></span></p> </li> </ul> <p><span><span>Data collection was carried out meticulously, following specific steps to ensure the accuracy and reliability of the results. The calibration certificates issued by the supplier (calibration_certificate.pdf) corresponding to the equipment used in the experiments and data collection that give rise to these databases are attached.</span></span></p>
FIGURE 1 in Fourier transform infrared spectroscopy (FTIR) characteristics of ancient amber artifacts of the Han Dynasty from Hunan, China
FIGURE 1. Possible ancient trade roadmap of both the Eurasian Steppe Silk Road and the Maritime Silk Road. 1, the present Capital, Beijing; 2, the ancient Capital city during the Han Dynasty, Xi'an, Shaanxi Province; 3, Nanyang, Henan Province, where unearthed artifacts of Han Dynasty made by Burmese amber (Chen et al., 2019); 4, Tomb Changchen M010, Changsha, Hunan Province; 5, Tomb Chentie M001, Chenzhou, Hunan Province.
FIGURE 3 in Fourier transform infrared spectroscopy (FTIR) characteristics of ancient amber artifacts of the Han Dynasty from Hunan, China
FIGURE 3. FTIR spectra of amber samples. A, SYS20220716-1. B, SYS20020716-2. C, SYS20220716-4. D, SYS20220716-5.
Impact of Fourier Transform Infrared Spectroscopy (FTIRS) in ICUs
ClinicalTrials.gov study NCT05872152. IPD Sharing: NO. Countries: 1. Publications: 5.
Fourier transform infrared spectroscopy spectra from North Anatolian fault peridotite xenoliths
<p>Fourier transform infrared spectroscopy spectra from North Anatolian fault peridotite xenoliths.</p>
Fourier transform infrared (FTIR) spectroscopy as a screening tool for osteosarcopenia in community-dwelling older women
<p>Dataset generated by MATLAB to be analyzed and identify osteosarcopenic women. </p>
Simultaneous Determination of Glucose and Albumin in Human Urine for Diagnosing Albuminuria using Attenuated Total Reflection Fourier-Transform Infrared Spectroscopy
<p>The manuscript has not yet been published.</p> <p> </p>
Fourier Transformed Infrared Spectroscopy in Macular Surgery
ClinicalTrials.gov study NCT03452748. IPD Sharing: Not stated. Countries: 1. Publications: 0.
Detection of Benign and Malignant Thyroid and Breast Tumors by Fourier Transform Infrared Spectrometry
ClinicalTrials.gov study NCT01668238. IPD Sharing: Not stated. Countries: 1. Publications: 0.
FIGURE 2 in Fourier transform infrared spectroscopy (FTIR) characteristics of ancient amber artifacts of the Han Dynasty from Hunan, China
FIGURE 2. Amber beads of the Han Dynasty from Hunan. A, Profile views of ZK14248. B, ZK14251, front and profile views. C, ZK14253; D, ZK14250, shattered bead with analyzed fragments. E, Broken amber bead (54changchenM010). F, Amber bead, SYS20220716-4. G, Amber bead SYS20220716-5. A–E, In collection of the Hunan Museum, Han Dynasty (202 BCE–220 CE). F and G, Amber beads obtained from local antique market or former private collection, presumed to be artifacts of the Han Dynasty, analyzed as references. Scale bars = 10mm.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.