zenodo48/100

Dataset of lightning flashovers on medium voltage distribution lines

<p>This <strong>synthetic dataset</strong> was generated from <strong>Monte Carlo</strong> simulations of <strong>lightning flashovers</strong> on medium voltage (MV) <strong>distribution lines</strong>. It is suitable for training <strong>machine learning</strong> models for classifying lightning flashovers on distribution lines. The dataset is <strong>hierarchical</strong> in nature (see below for more information) and <strong>class imbalanced</strong>.</p> <p>Following five different types of lightning interaction with the MV distribution line have been simulated: (1) direct strike to phase conductor (when there is no shield wire present on the line), (2) direct strike to phase conductor with shield wire(s) present on the line (i.e. shielding failure), (3) direct strike to shield wire with backflashover event, (4) indirect near-by lightning strike to ground where shield wire is not present, and (5) indirect near-by lightning strike to ground where shield wire is present on the line. Last two types of lightning interactions induce overvoltage on the phase conductors by radiating EM fields from the strike channel that are coupled to the line conductors. Three different methods of indirect strike analysis have been implemented, as follows: Rusck&#39;s model, Chowdhuri-Gross model and Liew-Mar model. Shield wire(s) provide shielding effects to direct, as well as screening effects to indirect, lightning strikes.</p> <p><strong>Dataset</strong> consists of two independent distribution lines, with heights of 12 m and 15 m, each with a flat configuration of phase conductors. Twin shield wires, if present, are 1.5 m above the phase conductors and 3 m apart [2]. CFO level of the 12 m distribution line is 150 kV and that of the 15 m distribution line is 160 kV. Dataset consists of <strong>10,000 simulations</strong> for each of the distribution lines.</p> <p>Dataset contains following variables (features):</p> <ul> <li>&#39;<em>dist</em>&#39;: perpendicular distance of the lightning strike location from the distribution line axis (m), generated from the Uniform distribution [0, 500] m,</li> <li>&#39;<em>ampl</em>&#39;: lightning current amplitude of the strike (kA), generated from the Log-Normal distribution (see IEC 60071 for additional information),</li> <li>&#39;<em>front</em>&#39;: lightning current wave-front time (us), generated from the Log-Normal distribution; it needs to be emphasized that amplitudes (ampl) and wave-front times (front), as random variables, have been generated from the appropriate bivariate probability distribution which includes statistical correlation between these variates,</li> <li>&#39;<em>veloc</em>&#39;: velocity of the lightning return-stroke current defined indirectly through the parameter &quot;w&quot; that is generated from the Uniform distribution [50, 500] m/us, which is then used for computing the velocity from the following relation: v = c/sqrt(1+w/I), where &quot;c&quot; is the speed of light in free space (300 m/us) and &quot;I&quot; is the lightning-current amplitude,</li> <li>&#39;<em>shield</em>&#39;: binary indicator that signals presence or absence of the shield wire(s) on the line (0/1), generated from the Bernoulli distribution with a 50% probability,</li> <li>&#39;<em>Ri</em>&#39;: average value of the impulse impedance of the tower&#39;s grounding (Ohm), generated from the Normal distribution (clipped at zero on the left side) with median value of 50 Ohm and standard deviation of 12.5 Ohm; it should be mentioned that the impulse impedance is often much larger than the associated grounding resistance value, which is why a rather high value of 50 Ohm have been used here,</li> <li>&#39;<em>EGM</em>&#39;: electrogeometric model used for analyzing striking distances of the distribution line&#39;s tower; following options are available: &#39;Wagner&#39;, &#39;Young&#39;, &#39;AW&#39;, &#39;BW&#39;, &#39;Love&#39;, and &#39;Anderson&#39;, where &#39;AW&#39; stands for Armstrong &amp; Whitehead, while &#39;BW&#39; means Brown &amp; Whitehead model; statistical distribution of EGM models follows a user-defined discrete categorical distribution with respective probabilities: p = [0.1, 0.2, 0.1, 0.1, 0.3, 0.2],</li> <li>&#39;<em>ind</em>&#39;: indirect stroke model used for analyzing near-by indirect lightning strikes; following options were implemented: &#39;rusk&#39; for the Rusck&#39;s model, &#39;chow&#39; for the Chowdhuri-Gross model (with Jakubowski modification) and &#39;liew&#39; for the Liew-Mar model; statistical distribution of these three models follows a user-defined discrete categorical distribution with respective probabilities: p = [0.6, 0.2, 0.2],</li> <li>&#39;<em>CFO</em>&#39;: critical flashover voltage level of the distribution line&#39;s insulation (kV),</li> <li>&#39;<em>height</em>&#39;: height of the phase conductors of the distribution line (m),</li> <li>&#39;<em>flash</em>&#39;: binary indicator that signals if the flashover has been recorded (1) or not (0). This variable is the outcome/label (i.e. binary class).</li> </ul> <p>Mathematical background used for the analysis of lightning interaction with the MV distribution line can be found in the references cited below.</p> <p><strong>References</strong>:</p> <ol> <li>A. R. Hileman, &quot;Insulation Coordination for Power Systems&quot;, CRC Press, Boca Raton, FL, 1999.</li> <li>J. A. Martinez and F. Gonzalez-Molina, &quot;Statistical evaluation of lightning overvoltages on overhead distribution lines using neural networks,&quot; in IEEE Transactions on Power Delivery, vol. 20, no. 3, pp. 2219-2226, July 2005.</li> <li>A. Borghetti, C. A. Nucci and M. Paolone, An Improved Procedure for the Assessment of Overhead Line Indirect Lightning Performance and Its Comparison with the IEEE Std. 1410 Method, IEEE Transactions on Power Delivery, Vol. 22, No. 1, 2007, pp. 684-692.</li> </ol>

opencc-by-4.0Nov 2022View details →
zenodo48/100

H2020 Platone German Demonstrator - Baseline Active Power Exchange at Grid Connection Point (Medium Voltage/Low Voltage)

<p>The given data are computed values for the active power exchange at the medium (MV)/low voltage grid connecting feeder (active power).&nbsp;The data are provided as 15-minutes mean values in kilowatt. The computed indicate the power exchange that would have been measured, in case no use case would have been applied in the field (control of batteries).</p> <p><strong>Data Description:</strong></p> <ul> <li>p_tei_c_mean =&nbsp;arithmetic mean of p_tei computed in 1-minute intervals devided by number of samples available for computing within 15 minutes (p_tei_count)</li> <li>p_tei_c_min = the minimum value (1-minute mean) computed within the period of&nbsp;p_tei_mean (15-minutes)</li> <li>p_tei_c_max =&nbsp;the maximum value (1-minute mean) computed within the period of p_tei_mean period (15-minutes)</li> </ul> <p><strong>Field Test Setup</strong></p> <p>The field test setup of the demonstrator consists of a MV/LV substation,&nbsp;89 households, 450kW of installed PV generation capacity, a large scale battery with 300 kW and 850 kWh capacity.&nbsp;</p> <p>This project has received funding from the European Union&rsquo;s Horizon 2020 research and innovation programme under grant agreement No 864300</p>

opencc-by-4.0Feb 2023View details →
zenodo44/100

Lightning flashover simulations on medium voltage distribution lines

<p>[Version 1.2] This version of the dataset fixes a bug found in the previous versions (see below for more information).</p> <p>Dataset has been generated from the <strong>Monte Carlo</strong> simulations of <strong>lightning flashovers</strong> on medium voltage (MV) <strong>distribution lines</strong>. It is suitable for training <strong>machine learning</strong> models for classifying lightning flashovers on distribution lines, as well as for line insulation coordination studies. The dataset is hierarchical in nature (see below for more information) and class imbalanced.</p> <p>Following five different types of lightning interaction with the MV distribution line have been simulated: (1) direct strike to phase conductor (when there is no shield wire present on the line), (2) direct strike to phase conductor with shield wire(s) present on the line (i.e. shielding failure), (3) direct strike to shield wire with backflashover event, (4) indirect near-by lightning strike to ground where shield wire is not present, and (5) indirect near-by lightning strike to ground where shield wire is present on the line. Last two types of lightning interactions induce overvoltage on the phase conductors by radiating EM fields from the strike channel that are coupled to the line conductors. Shield wire(s) provide shielding effects to direct, as well as screening effects to indirect, lightning strikes.</p> <p><strong>Dataset</strong> consists of the following variables:</p> <ul> <li>&#39;dist&#39;: perpendicular distance of the lightning strike location from the distribution line axis (m), generated from the Uniform distribution [0, 500] m,</li> <li>&#39;ampl&#39;: lightning current amplitude of the strike (kA), generated from the Log-Normal distribution (see IEC 60071 for additional information),</li> <li>&#39;veloc&#39;: velocity of the lightning return stroke current (m/us), generated from the Uniform distribution [50, 500] m/us,</li> <li>&#39;shield&#39;: binary indicator that signals presence or absence of the shield wire(s) on the line (0/1), generated from the Bernoulli distribution with a 50% probability,</li> <li>&#39;Ri&#39;: average value of the impulse impedance of the tower&#39;s grounding (Ohm), generated from the Normal distribution (clipped at zero on the left side) with median value of 50 Ohm and standard deviation of 12.5 Ohm; it should be mentioned that the impulse impedance is often much larger than the associated grounding resistance value, which is why a rather high value of 50 Ohm have been used here,</li> <li>&#39;EGM&#39;: electrogeometric model used for analyzing striking distances of the distribution line&#39;s tower; following options are available: &#39;Wagner&#39;, &#39;Young&#39;, &#39;AW&#39;, &#39;BW&#39;, &#39;Love&#39;, and &#39;Anderson&#39;, where &#39;AW&#39; stands for Armstrong &amp; Whitehead, while &#39;BW&#39; means Brown &amp; Whitehead model; statistical distribution of EGM models follows a user-defined discrete categorical distribution with respective probabilities: p = [0.1, 0.2, 0.1, 0.1, 0.3, 0.2],</li> <li>&#39;CFO&#39;: critical flashover voltage level of the distribution line&#39;s insulation (kV); following three levels have been used: 150, 150, and 160 kV, respectively, for three different distribution lines of height 10, 12, and 14 m,</li> <li>&#39;height&#39;: height of the phase conductors of the distribution line (m); distribution line has flat configuration of phase conductors with following heights: 10, 12, and 14 m; twin shield wires, if present, are 1.5 m above the phase conductors and 3 m apart; data set consists of 10000 simulations for each line height,</li> <li>&#39;flash&#39;: binary indicator that signals if the flashover has been recorded (1) or not (0). This variable is the outcome (binary class).</li> </ul> <p><strong>Note</strong>: It should be mentioned that the critical flashover voltage (CFO) level of the line is taken at 150 kV for the first two lines (10 m and 12 m) and 160 kV for the third line (14 m), and that the diameters of the phase conductors and shield wires for all treated lines are, respectively, 10 mm and 5 mm. Also, average grounding resistance of the shield wire is assumed at 10 Ohm for all treated cases (it has no discernible influence on the flashover rate). Dataset is class imbalanced and consists in total of 30000 simulations, with 10000 simulations for each of the three different MV distribution line heights (geometry) and CFO levels.</p> <p><strong>Important</strong>: Version 1.2 of the dataset fixes an important bug found in the previous data sets, where the column &#39;Ri&#39; contained duplicate data from the column &#39;veloc&#39;. This issue is now resolved.</p> <p>Mathematical background used for the analysis of lightning interaction with the MV distribution line can be found in the references below.</p> <p><strong>References</strong>:</p> <p>J. A. Martinez and F. Gonzalez-Molina, &quot;Statistical evaluation of lightning overvoltages on overhead distribution lines using neural networks,&quot; in IEEE Transactions on Power Delivery, vol. 20, no. 3, pp. 2219-2226, July 2005, doi: 10.1109/TPWRD.2005.848734.</p> <p>A. R. Hileman, &quot;Insulation Coordination for Power Systems&quot;, CRC Press, Boca Raton, FL, 1999.</p>

opencc-by-4.0Mar 2022View details →
zenodo44/100

Reference data set for a Norwegian medium voltage power distribution system

<p>This reference data set describes a representative Norwegian radial, medium voltage (MV) electric power distribution system operated at 22 kV. The data set is developed in the Norwegian research centre CINELDI and will in brief be referred to as the CINELDI MV reference system.</p> <p>Data for a real Norwegian distribution system were provided by a distribution grid company. The data have been anonymized and processed to obtain a simplified but still realistic grid model with 124 nodes. The data set consists of the following three parts:<br> 1. Grid data files: describe the base version of the reference system that represents the present-day state of the grid, including information about topology, electrical parameters, and existing load points.<br> 2. Load data files: comprise load demand time series for a year with hourly resolution and scenarios for the possible long-term development of peak load. These data describe an extended version of the reference system with information about possible new load points being added to the system in the future.<br> 3. Reliability data files: contain data necessary for carrying out reliability of supply analyses for the system.</p> <p>The data set is described in detail in the following data article:<br> I. B. Sperstad, O. B. Fosso, S. H. Jakobsen, A. O. Eggen, J. H. Evenstuen, and G. Kj&oslash;lle, &ldquo;Reference data set for a Norwegian medium voltage power distribution system,&rdquo; Data in Brief, 109025, 2023, doi: 10.1016/j.dib.2023.109025.</p>

opencc-by-4.0Oct 2022View details →
zenodo40/100

Risk Assessment of Extreme Precipitation on to Low- and Medium-Voltage Electrical Infrastructure Under the Influence of Climate Change

Open the record for dataset details and reuse information.

opencc-by-4.0May 2024View details →
zenodo40/100

Time Series Measurement Data of Medium Voltage | Low Voltage [MV|LV] Feeders in Jabodetabek Regions Indonesia – District Incoming Transformers of 630 kVA & 400 kVA (20 kV | 0.4 kV)

<p>Time Series Measurement Data of Medium Voltage | Low Voltage (MV|LV] Feeders in Jabodetabek Regions Indonesia &ndash; District Incoming Transformers of 630 kVA &amp; 400 kVA&nbsp;(20 kV | 0.4 kV)<br> Standardized Power Quality Analyzer took the data within 1- and 5 minutes span data during seven days in 2016.&nbsp;<br> The data consist&nbsp;of Voltage, Current, Active/Reactive/Apparent Power, Power Factor, and Total Harmonic Distortion (THD) within three-phase measurement. Related data was also included with it i.e., calculated data for active power losses, Unbalanced Voltage per phase, efficiency etc</p>

opencc-by-4.0Apr 2022View details →
zenodo36/100

180-Bus Medium Voltage Distribution Network Data

<p>The data describes a realistic medium-voltage distribution network with 180 buses, 90 loads (6799 consumers), 5 EV parking lots, 2 Energy Storage Systems, 42 Wind Farms, 33 PV parks, 3 biomasses, and 1 substation supplied by a transformer with 1 MVA and 30 kV.</p> <p>The network characteristics, such as cable resistances, reactances, and thermal limits, are available.</p> <p>Demand, EV demand, and PV/Wind generation profiles are presented for 64 scenarios.</p>

opencc-by-4.0Dec 2023View details →
zenodo36/100

Data set for the publication " Evaluation of the Accuracy and Frequency Response of Medium-Voltage Instrument Transformers under the Combined Influence Factors of Temperature and Vibration"

<p>This is dataset for paper published:</p> <p>Agazar, M.; Istrate, D.; Pradayrol, P. Evaluation of the Accuracy and Frequency Response of Medium-Voltage Instrument Transformers under the Combined Influence Factors of Temperature and Vibration.&nbsp;<em>Energies</em>&nbsp;<strong>2023</strong>,&nbsp;<em>16</em>, 5012. https://doi.org/10.3390/en16135012</p>

opencc-by-4.0Aug 2023View details →
dryad36/100

Data from: Two-phase immersion cooler for medium-voltage silicon carbide MOSFETs

Open the record for dataset details and reuse information.

publicSep 2025View details →
zenodo24/100

H2020 Platone German Demonstrator - Active Power Exchange at Grid Connection Point (Medium Voltage/Low Voltage)

<p>The given data are measured values of active power , measured at the low voltage busbar of the medium voltage (MV)/low voltage (LW) grid connection point (secondary substation).&nbsp;The data are provided as 15-minutes mean values in kilowatt.</p> <p><strong>Data Description</strong></p> <ul> <li>p_tei_mean =&nbsp;arithmetic mean of p_tei measured in 1-minute intervals devided by number of samples available for computing within 15 minutes (p_tei_count)</li> <li>p_tei_min = the minimum value (1-minute mean) measured within the period of&nbsp;p_tei_mean (15-minutes)</li> <li>p_tei_max =&nbsp;the maximum value (1-minute mean) measured within the period of p_tei_mean period (15-minutes)</li> <li>p_tei_count =&nbsp;the number a 1-minute mean values available for&nbsp;each15-minute interval.</li> </ul> <p><strong>Field Test Setup</strong></p> <p>The substation includes a transformer feeding a low voltage grid, consisting of 89 households, 450kW of installed PV generation capacity, a large scale battery with 300 kW and 850 kWh.&nbsp;</p> <p>This project has received funding from the European Union&rsquo;s Horizon 2020 research and innovation programme under grant agreement No 864300</p>

openJan 2023View details →
zenodo12/100

Dataset for the manuscript: Design and Characterization of PCB Spiral Coils for Inductive Power Transfer in Medium Voltage Applications

<p>This repository includes datasets supporting our manuscript that is under review process in the IEEE Transaction on Power Electronics.&nbsp;</p> <p>In this first version, we include the data set necessary to reproduce the results of Fig. 6 in the manuscript, which are dimensionless functions for resistance of copper traces with rectangular cross-section.</p> <p>There are two excel files in the repository, one is for the conduction loss and another is for the proximity loss. They both are extracted from&nbsp;Ansys EM simulation.&nbsp;</p> <p>In the simulation, frequency are sweeping from 50 kHz to 1 MHz, copper trace width is sweeping from 1 mm to 20 mm. the thickness of copper trace is sweeping from 0.07 mm to 0.21 mm (since we are considering standard PCB trace thickness here). The copper conductivity we set in the simulation is 5.8e7 Siemens/m.</p>

restrictedOct 2021View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.