Skip to main content
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

1

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

1 result for “Steel moment resisting frames”

Learn how ShareScore rates datasets ↗
zenodo48/100

Dataset on the experimental investigation of the seismic response of moment-resisting steel frames using shaking table tests

<h2>Description:</h2> <p>This dataset contains data from experimental shake table tests conducted on a two-storey steel-frame structure, involving linear sweep, white noise, impulse, and seismic excitations (see 'Load_Protocols_v1.0.0.pdf'). The experiments were carried out using the uniaxial shaking table at the&nbsp;<a href="https://www.lbb.rwth-aachen.de/cms/lbb/der-lehrstuhl/~bjlfvq/geraetezentzrum/?lidx=1">RWTHDynLab</a> of the&nbsp;<a href="https://www.lbb.rwth-aachen.de/go/id/eaxh/">Chair of Structural Analysis and Dynamics (LBB) - RWTH Aachen University</a>, in cooperation with the <a href="https://www.stb.rwth-aachen.de/cms/~iozv/STB/">Institute of Structural Steel (STB) - RWTH Aachen</a> and the <a href="https://www.cwe.rwth-aachen.de/home-2/">Center for Wind and Earthquake Engineering (CWE) &ndash; RWTH Aachen</a>.</p> <p>The experimental campaign was developed to gain a better understanding of the interaction between the main structure and non-structural components, to investigate the reliability and accuracy of analytical methods to predict response floor spectra and non-structural component acceleration described in various guidelines and seismic codes. Regarding applications of Structural Health Monitoring the necessity for additional sensors on non-structural components was studied. Three single-degree-of-freedom oscillators (SDOFs) were connected to the upper floor representing non-structural components. The test structure was subjected to a total of twelve earthquake excitations with different spectral properties. The main objectives of the test campaign were:</p> <ul> <li>Identification of the modal properties of the test structure.</li> <li>Measurement of the floor response in terms of acceleration and displacement.</li> <li>Determination of the real floor response spectra based on the measurements of the acceleration sensors installed on the first and second floors.</li> <li>Comparison of the expected peak accelerations from the floor response spectra with the peak accelerations measured by the accelerometers attached to the three SDOFs.</li> </ul> <h3>Test structure:</h3> <p>The test structure consisted of a two-storey steel structure which was stabilised in the direction of excitation by moment resisting frames (MRFs). In the transverse direction the global stability was ensured by concentrically braced frames (braces QRo 50x5). The structure was designed in accordance with provisions of prEN-1998-1 for energy dissipation and ductile seismic behaviour. As ductile members were considered the frame beams so that the columns and connections remain undamaged. An illustration of the test structure is depicted in 'Test_Structure_Sketch_v1.0.0.pdf'. The dimensions of the test structure are: 2.40 m in length, 2.40 m in width and 3.78 m in total height (1st storey: 2.02 m; 2nd storey: 1.76 m). Four large steel I-sections, each with a dead weight of 1700 kg, were attached to the main structure as masses and secured by U-Profiles. A tank with a dead load of approx. 100 kg and a volume of 400 litres was mounted onto the first floor. The tank remained empty during this test series. HEA200 profiles (S355-J2) were selected as column profiles, whereas IPE160 profiles (S235-JR) as frame beams. All main and secondary beams were realised by HEA140 profiles (S235-JR). Four L60x6 bars were arranged in a rhombus shape in the floor plane to ensure a diaphragm action. In the area of the MRF connections, the columns were reinforced with an additional double web plate (t = 10 mm) and with three ribs (t = 10 mm) at the level of the beam top flange, the beam bottom flange and the haunch flange. The beam-to-column connections were classified as full strength and semi-rigid in terms of capacity and stiffness. The critical welds connecting the frame transom to the top plate (t = 15 mm) were designed as full penetration groove welds in accordance with the specifications of Annex E of prEN1998-1 for seismically standardised connections. Twelve M16-10.9 bolts were used to ensure the force transfer between the beam and column. All connections of the secondary beams to the main beams were realised as end plate connections to prevent premature failure due to combined loading by normal and shear forces. The arrangement of the secondary beams and the corresponding force transmission was conceptualized in such a way that the frame beams could be replaced after a series of tests without having to remove the masses and the tank. The columns were hinged to the shaking table (see 'Column_Base_Anchorage_v1.0.0.pdf'). Slots in the anchor plates allow the rotation of the support base around the strong axis of the columns. The anchoring to the shaking table was realised using four M24-8.8 threaded rods. To simulate non-structural components, three SDOFs were attached to the centre of the secondary beams that run across the frame transom on the second floor (see 'Test_Structure_v1.0.0.pdf'). The SDOFs consisted of a flat steel and a mass. Depending on the thickness of the flat steel and the position of the mass, the three SDOFs were calibrated so that the natural frequency of the first SDOF matches the natural frequency of the second modal shape of the test structure in the frame direction, and the natural frequency of the third SDOF corresponds the first natural frequency of the structure. The natural frequency of the second SDOF was set so that it lies between those of the other SDOFs, creating a staggered range of dynamic responses.</p> <h3>Test setup:</h3> <p>The shaking table specifications are:</p> <ul> <li>Table size: 3.0x3.0 m</li> <li>Max. specimen mass: 10 t</li> <li>Max. overturning moment: 30 m t</li> <li>Max. actuator stroke: +/- 250 mm</li> <li>Max. table velocity: +/- 1 m/s at rated load</li> <li>Max. table acceleration: +/- 1g at rated load</li> <li>Test frequency: 0 to 50 Hz</li> </ul> <p>The instrumentation scheme of the test setup consisted of accelerometers and displacement tranducers, measuring the excitation provided by the shaking table and the response of the structure. Regarding the global response of the test structure, the recordings of the accelerometers and displacement tranducers indicated in the uploaded file 'Instrumentation_Scheme_v1.0.0.pdf' are provided.&nbsp;</p> <p>The properties of the accelerometers are:</p> <ul> <li>Type: M3701-series</li> <li>Manufacturer: PCB Piezotronics, Inc.</li> <li>Measurement range: +/- 3g</li> <li>Frequency range: 0-500 Hz</li> <li>Sensitivity: 900 mV/g</li> <li>Resolution: 2.2e-5g</li> <li>Noise: 1&nbsp;&micro;g/Hz<sup>-0.5</sup></li> </ul> <p>The properties of the displacement tranducers are:</p> <ul> <li>Type: LZW-M-500</li> <li>Manufacturer: WayCon Positionsmesstechnik GmbH</li> <li>Measurement range: +/- 250 mm</li> <li>Linearity: +/- 0.05%</li> <li>Repeatability: 0.01 mm</li> <li>Displacement force: &le;15 N</li> <li>Displacement speed: &le;5 m/s</li> </ul> <h2>Files:</h2> <ul> <li>Column_Base_Anchorage_v1.0.0.pdf <ul> <li>Photo of the column-base anchorage.</li> </ul> </li> <li>Data_v1.0.0.zip <ul> <li>Contains all data files according to the load protocols.</li> <li>The experimental data is provided as .csv files for each load protocol.&nbsp;</li> </ul> </li> <li>Instrumentation_Scheme_v1.0.0.pdf <ul> <li>.pdf file illustrating the sensor placements on the test structure.</li> </ul> </li> <li>Load_Protocols_v1.0.0.pdf <ul> <li>.pdf file listing all load protocols applied to the structure.</li> </ul> </li> <li>References_v1.0.0.bib <ul> <li>Contains a bibtex reference with the associated publications.</li> </ul> </li> <li>Shake_Table.jpg <ul> <li>Photo of the shaking table without any specimen.</li> </ul> </li> <li>Test_Structure_v1.0.0.pdf <ul> <li>Photo of the shaking table including the test structure.</li> </ul> </li> <li>Test_Structure_Sketch_v1.0.0.pdf <ul> <li>.pdf file illustrating the test structure.</li> </ul> </li> <li>Time_Histories_v1.0.0.pdf <ul> <li>.pdf file including plots of the measurement data.</li> </ul> </li> </ul> <h2>File format of the datasets:</h2> <p>The data is stored in .csv files, where each file contains the following columns (see also 'Instrumentation_Scheme_v1.0.0.pdf'):</p> <ul> <li>Time (s): Time in seconds since the start of the test (time step equals 0.0025 s).</li> <li>Acc_0 (m/s2): Acceleration signal measured in m/s<sup>2</sup> on the shaking table in the direction of excitation (Axis A-A).</li> <li>Acc_1 (m/s2): Acceleration response of the structure measured in m/s<sup>2</sup> on the first floor in the direction of excitation (Axis A-A).</li> <li>Acc_2 (m/s2): Acceleration response of the structure measured in m/s<sup>2</sup> on the second floor in the direction of excitation (Axis A-A).</li> <li>Acc_L (m/s2): Acceleration response of SDOF I measured in m/s<sup>2</sup> in the direction of excitation.</li> <li>Acc_F (m/s2): Acceleration response of SDOF II measured in m/s<sup>2</sup>&nbsp;in the direction of excitation.</li> <li>Acc_H (m/s2): Acceleration response of SDOF III measured in m/s<sup>2</sup>&nbsp;in the direction of excitation.</li> <li>Acc_G (m/s2): Acceleration response of the structure measured in m/s<sup>2</sup> on the second floor in the direction of excitation (Axis B-B).</li> <li>Acc_J (m/s2): Acceleration response of the structure measured in m/s<sup>2</sup> on the second floor in the transverse direction of excitation (Axis B-B).</li> <li>Dis_0 (mm): Displacement signal measured mm on the shaking table in the direction of excitation (Axis A-A).</li> <li>Dis_1 (mm): Displacement response of the structure measured in mm on the first floor in the direction of excitation (Axis A-A).</li> <li>Dis_2 (mm): Displacement response of the structure measured in mm on the second floor in the direction of excitation (Axis A-A).</li> </ul> <p>These data files can easily be uploaded using the pandas library in Python. For example by:</p> <pre><code>import pandas as pd df = pd.read_csv('1_IM_4mm.csv') time = df["Time (s)"] acc_0 = df["Acc_0 (m/s2)"] dis_0 = df["Dis_0 (mm)"]</code></pre> <h2>Contact:</h2> <p>Please send your enquiries regarding the shaking table to <a href="dynamics@lbb.rwth-aachen.de">dynamics@lbb.rwth-aachen.de</a>. Further information can be found on our <a href="https://www.lbb.rwth-aachen.de/cms/lbb/der-lehrstuhl/~bjlfvq/geraetezentzrum/?lidx=1">website</a>.</p> <h2>Usage/License:</h2> <ul> <li>The data is licensed under CC BY-SA 4.0.</li> <li>If you have used our data and are publishing your work, we ask you to please reference both <ul> <li>this database by its DOI, and</li> <li>any publication that is associated with the experiments. See the "References_v1.0.0.bib" for the associated publication references.</li> </ul> </li> </ul> <h2>Fundings:</h2> <ul> <li>Deutsche Forschungsgemeinschaft - <em>Grant number: INST 222/1161-1 FUGG</em>. Einaxialer Schwingtisch f&uuml;r dynamische Modell- und Bauteilversuche.</li> <li>Bundesministerium f&uuml;r Bildung und Forschung - <em>Grant number: 03G0892A</em>. ROBUST &ndash; Nutzerorientiertes Erdbebenfr&uuml;hwarnsystem mit intelligenten Sensorsystemen und digitalen Bauwerksmodellen &ndash; Entwicklung Installation und Anwendung von sensorbasierten Monitoringsystemen mit BIM-Integration zur Echtzeit-Schadenerkennung in kritischen Infrastrukturen.</li> </ul>

opencc-by-sa-4.0Nov 2024View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record