Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
4
datasets available to search
ShareScore release 0.9.0
Dataset results
4 results for “Trackerless”
Trackerless 3D Freehand Ultrasound Reconstruction Challenge 2024 - Train Dataset (Part 2)
<blockquote> <p><strong>This Challenge will be an open-ended challenge, and we welcome your submission. Please register your team via this <a title="https://forms.office.com/e/dPg47ktV7M" href="https://forms.office.com/e/dPg47ktV7M" target="_blank" rel="noopener">form</a>. You can submit the algorithm via this <a title="https://forms.office.com/e/QChhNkLYiu" href="https://forms.office.com/e/QChhNkLYiu" target="_blank" rel="noopener noreferrer">form</a> for TUS-REC2024 Challenge, and we will test your submitted docker on the test set.</strong></p> <p><strong>We are organising TUS-REC2025 at MICCAI2025. More information is available on the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/" target="_blank" rel="noopener">TUS-REC2025 challenge website</a> and <a href="https://github.com/QiLi111/TUS-REC2025-Challenge_baseline" target="_blank" rel="noopener">Baseline code repo</a>.</strong></p> </blockquote> <p><strong>This is the second part of the Challenge dataset. <a href="../doi/10.5281/zenodo.11178509" target="_blank" rel="noopener">Link</a> to first part; <a href="../doi/10.5281/zenodo.11355500" target="_blank" rel="noopener">Link</a> to third part. <a href="../doi/10.5281/zenodo.12979481" target="_blank" rel="noopener">Link</a> to validation dataset.</strong></p> <p>Acquisition devices and config: The 2D US images were acquired using an Ultrasonix machine (BK, Europe) with a curvilinear probe (4DC7-3/40). The associated position information of each frame was recorded by an optical tracker (NDI Polaris Vicra, Northern Digital Inc., Canada). The acquired US frames were recorded at 20 fps, with an image size of 480×640, without speckle reduction. The frequency was set at 6MHz with a dynamic range of 83 dB, an overall gain of 48% and a depth of 9 cm. </p> <div> <p>Scanning protocol: Both left and right forearms of volunteers were scanned. For each forearm, the US probe moves in three different trajectories (straight line shape, "C" shape, and "S" shape), in a distal-to-proximal direction followed by a proximal-to-distal direction, with the US plane perpendicular of and parallel to the scanning direction. The train dataset contains 1200 scans in total, 24 scans associated with each subject.</p> <div> <div> <p>For detailed information please refer to the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/TUS-REC2024/" target="_blank" rel="noopener">Challenge website</a>. Baseline code is also provided, which can be found at this <a href="https://github.com/QiLi111/tus-rec-challenge_baseline" target="_blank" rel="noopener">repo</a>.</p> <p>Dataset structure: </p> </div> <div> <ul> <li> <p>The dataset contains 50 folders (one subject per folder), each with 24 scans. Each .h5 file corresponds to one scan, storing image and transformation of each frame within this scan. Key-value pairs in each .h5 file are explained below.</p> <ul> <li> <p>“frames” - All frames in the scan; with a shape of [N,H,W], where N refers to the number of frames in the scan, H and W denote the height and width of a frame. </p> </li> <li> <p>“tforms” - All transformations in the scan; with a shape of [N,4,4], where N is the number of frames in the scan, and the transformation matrix denotes the transformation from tracker tool space to camera space. </p> </li> <li> <p>Notations in the name of each .h5 file: “RH”: right arm; “LH”: left arm; “Per”: perpendicular; “Par”: parallel; “L”: straight line shape; “C”: C shape; “S”: S shape; “DtP”: distal-to-proximal direction; “PtD”: proximal-to-distal direction; For example, “RH_Per_L_DtP.h5” denotes a scan on the right forearm, with ultrasound probe perpendicular of the forearm sweeping along straight line, in distal-to-proximal direction.</p> </li> </ul> </li> <li> <p>Calibration matrix: The calibration matrix was obtained using a pinhead-based method. The "scaling_from_pixel_to_mm" and "spatial_calibration_from_image_coordinate_system_to_tracking_tool_coordinate_system" are provided in the “calib_matrix.csv”. </p> </li> </ul> <div> <p><strong>Data Usage Policy:</strong></p> <ul> <li>The training and validation data provided may be utilized within the research scope of this challenge and in subsequent research-related publications. However, commercial use of the training and validation data is prohibited. In cases where the intended use is ambiguous, participants accessing the data are requested to abstain from further distribution or use outside the scope of this challenge.</li> <li>If you use our dataset in your publication, please cite the challenge paper and some of the following optional articles: <ul> <li>Challenge paper: <ul> <li><strong>Qi Li et al. "TUS-REC2024: A Challenge to Reconstruct 3D Freehand Ultrasound Without External Tracker." <em>arXiv preprint arXiv:<a title="https://arxiv.org/abs/2506.21765" href="https://doi.org/10.48550/arXiv.2506.21765" target="_blank" rel="noopener">2506.21765</a></em> (2025).</strong></li> </ul> </li> <li>Optional articles: <ul> <li>Qi Li, Ziyi Shen, Qianye Yang, Dean C. Barratt, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Nonrigid Reconstruction of Freehand Ultrasound without a Tracker." In <em>International Conference on Medical Image Computing and Computer-Assisted Intervention</em>, pp. 689-699. Cham: Springer Nature Switzerland, 2024. doi: <a href="https://doi.org/10.1007/978-3-031-72083-3_64" target="_blank" rel="noopener">10.1007/978-3-031-72083-3_64.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Long-term Dependency for 3D Reconstruction of Freehand Ultrasound Without External Tracker." IEEE Transactions on Biomedical Engineering, vol. 71, no. 3, pp. 1033-1042, 2024. doi: <a href="https://ieeexplore.ieee.org/abstract/document/10288201" target="_blank" rel="noopener">10.1109/TBME.2023.3325551</a>.</li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Trackerless freehand ultrasound with sequence modelling and auxiliary transformation over past and future frames." In 2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2023. doi: <a href="https://doi.org/10.1109/ISBI53787.2023.10230773" target="_blank" rel="noopener">10.1109/ISBI53787.2023.10230773.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Privileged Anatomical and Protocol Discrimination in Trackerless 3D Ultrasound Reconstruction." In International Workshop on Advances in Simplifying Medical Ultrasound, pp. 142-151. Cham: Springer Nature Switzerland, 2023. doi: <a href="https://doi.org/10.1007/978-3-031-44521-7_14" target="_blank" rel="noopener">https://doi.org/10.1007/978-3-031-44521-7_14.</a></li> </ul> </li> </ul> </li> </ul> </div> </div> </div> </div>
Trackerless 3D Freehand Ultrasound Reconstruction Challenge 2024 - Train Dataset (Part 1)
<blockquote> <p><strong>This Challenge will be an open-ended challenge, and we welcome your submission. Please register your team via this <a title="https://forms.office.com/e/dPg47ktV7M" href="https://forms.office.com/e/dPg47ktV7M" target="_blank" rel="noopener">form</a>. You can submit the algorithm via this <a title="https://forms.office.com/e/QChhNkLYiu" href="https://forms.office.com/e/QChhNkLYiu" target="_blank" rel="noopener noreferrer">form</a> for TUS-REC2024 Challenge, and we will test your submitted docker on the test set.</strong></p> <p><strong>We are organising TUS-REC2025 at MICCAI2025. More information is available on the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/" target="_blank" rel="noopener">TUS-REC2025 challenge website</a> and <a href="https://github.com/QiLi111/TUS-REC2025-Challenge_baseline" target="_blank" rel="noopener">Baseline code repo</a>.</strong></p> </blockquote> <p><strong>This is the first part of the Challenge train dataset. <a href="../doi/10.5281/zenodo.11180795" target="_blank" rel="noopener">Link</a> to second part; <a href="../doi/10.5281/zenodo.11355499" target="_blank" rel="noopener">Link</a> to third part. <a href="../doi/10.5281/zenodo.12979481" target="_blank" rel="noopener">Link</a> to validation dataset.</strong></p> <p>Acquisition devices and config: The 2D US images were acquired using an Ultrasonix machine (BK, Europe) with a curvilinear probe (4DC7-3/40). The associated position information of each frame was recorded by an optical tracker (NDI Polaris Vicra, Northern Digital Inc., Canada). The acquired US frames were recorded at 20 fps, with an image size of 480×640, without speckle reduction. The frequency was set at 6MHz with a dynamic range of 83 dB, an overall gain of 48% and a depth of 9 cm. </p> <div> <p>Scanning protocol: Both left and right forearms of volunteers were scanned. For each forearm, the US probe moves in three different trajectories (straight line shape, "C" shape, and "S" shape), in a distal-to-proximal direction followed by a proximal-to-distal direction, with the US plane perpendicular of and parallel to the scanning direction. The train dataset contains 1200 scans in total, 24 scans associated with each subject.</p> <p>For detailed information please refer to the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/TUS-REC2024/" target="_blank" rel="noopener">Challenge website</a>. Baseline code is also provided, which can be found at this <a href="https://github.com/QiLi111/tus-rec-challenge_baseline" target="_blank" rel="noopener">repo</a>.</p> <p>Dataset structure: </p> </div> <div> <ul> <li> <p>The dataset contains 50 folders (one subject per folder), each with 24 scans. Each .h5 file corresponds to one scan, storing image and transformation of each frame within this scan. Key-value pairs in each .h5 file are explained below.</p> <ul> <li> <p>“frames” - All frames in the scan; with a shape of [N,H,W], where N refers to the number of frames in the scan, H and W denote the height and width of a frame. </p> </li> <li> <p>“tforms” - All transformations in the scan; with a shape of [N,4,4], where N is the number of frames in the scan, and the transformation matrix denotes the transformation from tracker tool space to camera space. </p> </li> <li> <p>Notations in the name of each .h5 file: “RH”: right arm; “LH”: left arm; “Per”: perpendicular; “Par”: parallel; “L”: straight line shape; “C”: C shape; “S”: S shape; “DtP”: distal-to-proximal direction; “PtD”: proximal-to-distal direction; For example, “RH_Per_L_DtP.h5” denotes a scan on the right forearm, with ultrasound probe perpendicular of the forearm sweeping along straight line, in distal-to-proximal direction.</p> </li> </ul> </li> <li> <p>Calibration matrix: The calibration matrix was obtained using a pinhead-based method. The "scaling_from_pixel_to_mm" and "spatial_calibration_from_image_coordinate_system_to_tracking_tool_coordinate_system" are provided in the “calib_matrix.csv”. </p> </li> </ul> <div> <p><strong>Data Usage Policy:</strong></p> <ul> <li>The training and validation data provided may be utilized within the research scope of this challenge and in subsequent research-related publications. However, commercial use of the training and validation data is prohibited. In cases where the intended use is ambiguous, participants accessing the data are requested to abstain from further distribution or use outside the scope of this challenge.</li> <li>If you use our dataset in your publication, please cite the challenge paper and some of the following optional articles: <ul> <li>Challenge paper: <ul> <li><strong>Qi Li et al. "TUS-REC2024: A Challenge to Reconstruct 3D Freehand Ultrasound Without External Tracker." <em>arXiv preprint arXiv:<a title="https://arxiv.org/abs/2506.21765" href="https://doi.org/10.48550/arXiv.2506.21765" target="_blank" rel="noopener">2506.21765</a></em> (2025).</strong></li> </ul> </li> <li>Optional articles: <ul> <li>Qi Li, Ziyi Shen, Qianye Yang, Dean C. Barratt, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Nonrigid Reconstruction of Freehand Ultrasound without a Tracker." In <em>International Conference on Medical Image Computing and Computer-Assisted Intervention</em>, pp. 689-699. Cham: Springer Nature Switzerland, 2024. doi: <a href="https://doi.org/10.1007/978-3-031-72083-3_64" target="_blank" rel="noopener">10.1007/978-3-031-72083-3_64.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Long-term Dependency for 3D Reconstruction of Freehand Ultrasound Without External Tracker." IEEE Transactions on Biomedical Engineering, vol. 71, no. 3, pp. 1033-1042, 2024. doi: <a href="https://ieeexplore.ieee.org/abstract/document/10288201" target="_blank" rel="noopener">10.1109/TBME.2023.3325551</a>.</li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Trackerless freehand ultrasound with sequence modelling and auxiliary transformation over past and future frames." In 2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2023. doi: <a href="https://doi.org/10.1109/ISBI53787.2023.10230773" target="_blank" rel="noopener">10.1109/ISBI53787.2023.10230773.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Privileged Anatomical and Protocol Discrimination in Trackerless 3D Ultrasound Reconstruction." In International Workshop on Advances in Simplifying Medical Ultrasound, pp. 142-151. Cham: Springer Nature Switzerland, 2023. doi: <a href="https://doi.org/10.1007/978-3-031-44521-7_14" target="_blank" rel="noopener">https://doi.org/10.1007/978-3-031-44521-7_14.</a></li> </ul> </li> </ul> </li> </ul> </div> </div>
Trackerless 3D Freehand Ultrasound Reconstruction Challenge 2024 - Train Dataset (Part 3)
<div> <blockquote> <p><strong>This Challenge will be an open-ended challenge, and we welcome your submission. Please register your team via this <a title="https://forms.office.com/e/dPg47ktV7M" href="https://forms.office.com/e/dPg47ktV7M" target="_blank" rel="noopener">form</a>. You can submit the algorithm via this <a title="https://forms.office.com/e/QChhNkLYiu" href="https://forms.office.com/e/QChhNkLYiu" target="_blank" rel="noopener noreferrer">form</a> for TUS-REC2024 Challenge, and we will test your submitted docker on the test set.</strong></p> <p><strong>We are organising TUS-REC2025 at MICCAI2025. More information is available on the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/" target="_blank" rel="noopener">TUS-REC2025 challenge website</a> and <a href="https://github.com/QiLi111/TUS-REC2025-Challenge_baseline" target="_blank" rel="noopener">Baseline code repo</a>.</strong></p> </blockquote> <p><strong>This is the third part of the Challenge dataset. <a href="../doi/10.5281/zenodo.11178509" target="_blank" rel="noopener">Link</a> to first part; <a href="../doi/10.5281/zenodo.11180795" target="_blank" rel="noopener">Link</a> to second part. <a href="../doi/10.5281/zenodo.12979481" target="_blank" rel="noopener">Link</a> to validation dataset.</strong></p> <p>For detailed information please refer to the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/TUS-REC2024/" target="_blank" rel="noopener">Challenge website</a>. Baseline code is also provided, which can be found at this <a href="https://github.com/QiLi111/tus-rec-challenge_baseline" target="_blank" rel="noopener">repo</a>.</p> <p>Dataset structure: The dataset contains 50 .h5 files. Each corresponds to one subject, storing coordinates of landmarks for 24 scans of this subject. For each scan, the coordinates are stored in numpy array with shape of [20,3]. The first column is the index of frames; the second and third columns denote the coordinates of landmarks in the image coordinate system. </p> </div> <div> <p> </p> <p><strong>Data Usage Policy:</strong></p> <ul> <li>The training and validation data provided may be utilized within the research scope of this challenge and in subsequent research-related publications. However, commercial use of the training and validation data is prohibited. In cases where the intended use is ambiguous, participants accessing the data are requested to abstain from further distribution or use outside the scope of this challenge.</li> <li>If you use our dataset in your publication, please cite the challenge paper and some of the following optional articles: <ul> <li>Challenge paper: <ul> <li><strong>Qi Li et al. "TUS-REC2024: A Challenge to Reconstruct 3D Freehand Ultrasound Without External Tracker." <em>arXiv preprint arXiv:<a title="https://arxiv.org/abs/2506.21765" href="https://doi.org/10.48550/arXiv.2506.21765" target="_blank" rel="noopener">2506.21765</a></em> (2025).</strong></li> </ul> </li> <li>Optional articles: <ul> <li>Qi Li, Ziyi Shen, Qianye Yang, Dean C. Barratt, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Nonrigid Reconstruction of Freehand Ultrasound without a Tracker." In <em>International Conference on Medical Image Computing and Computer-Assisted Intervention</em>, pp. 689-699. Cham: Springer Nature Switzerland, 2024. doi: <a href="https://doi.org/10.1007/978-3-031-72083-3_64" target="_blank" rel="noopener">10.1007/978-3-031-72083-3_64.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Long-term Dependency for 3D Reconstruction of Freehand Ultrasound Without External Tracker." IEEE Transactions on Biomedical Engineering, vol. 71, no. 3, pp. 1033-1042, 2024. doi: <a href="https://ieeexplore.ieee.org/abstract/document/10288201" target="_blank" rel="noopener">10.1109/TBME.2023.3325551</a>.</li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Trackerless freehand ultrasound with sequence modelling and auxiliary transformation over past and future frames." In 2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2023. doi: <a href="https://doi.org/10.1109/ISBI53787.2023.10230773" target="_blank" rel="noopener">10.1109/ISBI53787.2023.10230773.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Privileged Anatomical and Protocol Discrimination in Trackerless 3D Ultrasound Reconstruction." In International Workshop on Advances in Simplifying Medical Ultrasound, pp. 142-151. Cham: Springer Nature Switzerland, 2023. doi: <a href="https://doi.org/10.1007/978-3-031-44521-7_14" target="_blank" rel="noopener">https://doi.org/10.1007/978-3-031-44521-7_14.</a></li> </ul> </li> </ul> </li> </ul> </div>
Trackerless 3D Freehand Ultrasound Reconstruction Challenge 2024 - Validation Dataset
<blockquote> <p><strong>This Challenge will be an open-ended challenge, and we welcome your submission. Please register your team via this <a title="https://forms.office.com/e/dPg47ktV7M" href="https://forms.office.com/e/dPg47ktV7M" target="_blank" rel="noopener">form</a>. You can submit the algorithm via this <a title="https://forms.office.com/e/QChhNkLYiu" href="https://forms.office.com/e/QChhNkLYiu" target="_blank" rel="noopener noreferrer">form</a> for TUS-REC2024 Challenge, and we will test your submitted docker on the test set.</strong></p> <p><strong>We are organising TUS-REC2025 at MICCAI2025. More information is available on the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/" target="_blank" rel="noopener">TUS-REC2025 challenge website</a> and <a href="https://github.com/QiLi111/TUS-REC2025-Challenge_baseline" target="_blank" rel="noopener">Baseline code repo</a>.</strong></p> </blockquote> <p><strong>This is the validation dataset. The training dataset is available at <a href="../doi/10.5281/zenodo.11178508" target="_blank" rel="noopener">Part1</a>, <a href="../doi/10.5281/zenodo.11180795" target="_blank" rel="noopener">Part2</a>, and <a href="../doi/10.5281/zenodo.11355499" target="_blank" rel="noopener">Part3</a>.</strong></p> <p>Acquisition devices and config: The 2D US images were acquired using an Ultrasonix machine (BK, Europe) with a curvilinear probe (4DC7-3/40). The associated position information of each frame was recorded by an optical tracker (NDI Polaris Vicra, Northern Digital Inc., Canada). The acquired US frames were recorded at 20 fps, with an image size of 480×640, without speckle reduction. The frequency was set at 6MHz with a dynamic range of 83 dB, an overall gain of 48% and a depth of 9 cm. </p> <div> <p>Scanning protocol: Both left and right forearms of volunteers were scanned. For each forearm, the US probe moves in three different trajectories (straight line shape, "C" shape, and "S" shape), in a distal-to-proximal direction followed by a proximal-to-distal direction, with the US plane perpendicular of and parallel to the scanning direction. The validation dataset contains 72 scans in total, 24 scans associated with each subject.</p> <p>For detailed information please refer to the <a href="https://github-pages.ucl.ac.uk/tus-rec-challenge/TUS-REC2024/" target="_blank" rel="noopener">Challenge website</a>. Baseline code is also provided, which can be found at this <a href="https://github.com/QiLi111/tus-rec-challenge_baseline" target="_blank" rel="noopener">repo</a>.</p> <p>Dataset structure: </p> <ul> <li>Folder <code>frames</code>: contains three folders (one subject per folder), each with 24 scans. Each .h5 file corresponds to one scan, storing image of each frame within this scan. Key-value pair and name of each .h5 file are explained below. <ul> <li>“frames” - All frames in the scan; with a shape of [N,H,W], where N refers to the number of frames in the scan, H and W denote the height and width of a frame. </li> <li>Notations in the name of each .h5 file: “RH”: right arm; “LH”: left arm; “Per”: perpendicular; “Par”: parallel; “L”: straight line shape; “C”: C shape; “S”: S shape; “DtP”: distal-to-proximal direction; “PtD”: proximal-to-distal direction; For example, “RH_Per_L_DtP.h5” denotes a scan on the right forearm, with ultrasound probe perpendicular of the forearm sweeping along straight line, in distal-to-proximal direction.</li> </ul> </li> </ul> </div> <div> <ul> <li>Folder <code>transfs</code>: contains three folders (one subject per folder), each with 24 scans. Each .h5 file corresponds to one scan, storing transformation of each frame within this scan. Key-value pair and name of each .h5 file are explained below. <ul> <li>“tforms” - All transformations in the scan; with a shape of [N,4,4], where N is the number of frames in the scan, and the transformation matrix denotes the transformation from tracker tool space to camera space. </li> <li>Notations in the name of each .h5 file is the same as in folder <code>frames</code>.</li> </ul> </li> <li>Folder <code>landmark</code>: contains three .h5 files. Each corresponds to one subject, storing coordinates of landmarks for 24 scans of this subject. For each scan, the coordinates are stored in numpy array with a shape of [20,3]. The first column is the index of frame; the second and third columns denote the coordinates of landmarks in the image coordinate system.</li> <li><code>calib_matrix.csv</code>: The calibration matrix was obtained using a pinhead-based method. The "scaling_from_pixel_to_mm" and "spatial_calibration_from_image_coordinate_system_to_tracking_tool_coordinate_system" are provided in the “calib_matrix.csv”.</li> <li><code>dataset_keys.h5</code>: stores the paths to all the scans of the data set. Keys in “dataset_keys.h5” denotes all the available scans in validation set, in a format of “sub%03d__%s” where %03d denotes folder name, and %s denotes the scan name. For example, “sub050__LH_Par_C_DtP” means the scan in folder “050”, with file name of “LH_Par_C_DtP.h5”</li> </ul> <div> <p><strong>Data Usage Policy:</strong></p> <ul> <li>The training and validation data provided may be utilized within the research scope of this challenge and in subsequent research-related publications. However, commercial use of the training and validation data is prohibited. In cases where the intended use is ambiguous, participants accessing the data are requested to abstain from further distribution or use outside the scope of this challenge.</li> <li><span>If you use our dataset in your publication, </span>please cite the challenge paper and some of the following optional articles: <ul> <li>Challenge paper: <ul> <li><strong>Qi Li et al. "TUS-REC2024: A Challenge to Reconstruct 3D Freehand Ultrasound Without External Tracker." <em>arXiv preprint arXiv:<a title="https://arxiv.org/abs/2506.21765" href="https://doi.org/10.48550/arXiv.2506.21765" target="_blank" rel="noopener">2506.21765</a></em> (2025).</strong></li> </ul> </li> <li>Optional articles:<br> <ul> <li>Qi Li, Ziyi Shen, Qianye Yang, Dean C. Barratt, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Nonrigid Reconstruction of Freehand Ultrasound without a Tracker." In <em>International Conference on Medical Image Computing and Computer-Assisted Intervention</em>, pp. 689-699. Cham: Springer Nature Switzerland, 2024. doi: <a href="https://doi.org/10.1007/978-3-031-72083-3_64" target="_blank" rel="noopener">10.1007/978-3-031-72083-3_64.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Long-term Dependency for 3D Reconstruction of Freehand Ultrasound Without External Tracker." IEEE Transactions on Biomedical Engineering, vol. 71, no. 3, pp. 1033-1042, 2024. doi: <a href="https://ieeexplore.ieee.org/abstract/document/10288201" target="_blank" rel="noopener">10.1109/TBME.2023.3325551</a>.</li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Trackerless freehand ultrasound with sequence modelling and auxiliary transformation over past and future frames." In 2023 IEEE 20th International Symposium on Biomedical Imaging (ISBI), pp. 1-5. IEEE, 2023. doi: <a href="https://doi.org/10.1109/ISBI53787.2023.10230773" target="_blank" rel="noopener">10.1109/ISBI53787.2023.10230773.</a></li> <li>Qi Li, Ziyi Shen, Qian Li, Dean C. Barratt, Thomas Dowrick, Matthew J. Clarkson, Tom Vercauteren, and Yipeng Hu. "Privileged Anatomical and Protocol Discrimination in Trackerless 3D Ultrasound Reconstruction." In International Workshop on Advances in Simplifying Medical Ultrasound, pp. 142-151. Cham: Springer Nature Switzerland, 2023. doi: <a href="https://doi.org/10.1007/978-3-031-44521-7_14" target="_blank" rel="noopener">https://doi.org/10.1007/978-3-031-44521-7_14.</a></li> </ul> </li> </ul> </li> </ul> </div> </div>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.