Skip to main content
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

91

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

91 results for “carbon ion”

Learn how ShareScore rates datasets ↗
zenodo40/100

Bio‐derived Carbon Nanofibres from Lignin as High‐Performance Li‐Ion Anode Materials

<p>Development of cost‐effective and increasingly efficient sustainable materials for energy‐storage devices, such Li‐ion batteries, is of crucial future importance. Herein, the preparation of carbon nanofibres from biopolymer blends of lignin (byproduct from the paper and pulp industry) and polylactic acid (PLA) or a thermoplastic elastomeric polyurethane (TPU) is described. SEM analysis shows the evolving microstructural morphology after each processing step (electrospinning, stabilisation and carbonisation). Importantly, it is possible to tailor the nanofibre porosity by utilising miscibility/immiscibility rules between lignin and the polymer additive (PLA/TPU). PLA blends (immiscible) generate porous structures whereas miscible lignin/TPU blends are solid when carbonised. Electrodes produced from 50&thinsp;% PLA blends have capacity values of 611 mAh&thinsp;g<sup>&minus;1</sup> after 500 charge/discharge cycles, the highest reported to date for sustainable electrodes for Li‐ion batteries. Thus, this work will promote the development of lignocellulose waste materials as high‐performance energy‐storage materials.</p>

opencc-by-4.0Aug 2019View details →
zenodo40/100

Carbon-Substituted Amines of the Cobalt Bis(dicarbollide) Ion: Stereochemistry and Acid–Base Properties

<p>Analytical dataset for "Carbon-Substituted Amines of the Cobalt Bis(dicarbollide) Ion: Stereochemistry and Acid&ndash;Base Properties"</p>

opencc-by-4.0Oct 2024View details →
zenodo36/100

Data set related to the manuscript "Ionic liquids under confinement: From systematic variations of the ion and pore sizes towards an understanding of structure and dynamics in complex porous carbons"

<p>Graphical files in the agr format for all the figures in the main text of the manuscript entitled &quot;Ionic liquids under confinement:&nbsp; From systematic variations of the ion and pore sizes towards an understanding of structure and dynamics in complex porous carbons&quot; (10.1021/acsami.9b16740). Example of input file for one of the systems simulated.</p>

opencc-by-4.0Dec 2019View details →
zenodo36/100

Data set related to the manuscript "Dynamics and energetics of ion adsorption at the interface between a pure ionic liquid and carbon electrodes"

<p>Text files with data for plotting figures in the quoted manuscript. Example input files for simulations.</p>

opencc-by-4.0Feb 2024View details →
zenodo36/100

Supporting data for "Electrochemical Removal of HF from Carbonate-based LiPF6-containing Li-ion Battery Electrolytes"

<p>This is the dataset of electrochemical experiments and BET analysis for our publication "Electrochemical Removal of HF from Carbonate-based LiPF6-containing Li-ion Battery Electrolytes" (DOI: <span><a href="https://doi.org/10.1149/1945-7111/ad30d3"><span>https://doi.org/10.1149/1945-7111/ad30d3</span></a></span>). This archive contains the raw data and Python Jupyter Notebook computer code to process, analyze, and generate the plots in this manuscript and its Supporting Information.</p> <p>&nbsp;</p> <p><span>Abstract for the manuscript:</span></p> <p>&nbsp;</p> <p><span>Due to the hydrolytic instability of LiPF6 in carbonate-based solvents, HF is a typical impurity in Li-ion battery electrolytes. HF significantly influences the performance of Li-ion batteries, for example by impacting the formation of the solid electrolyte interphase at the anode and by affecting transition metal dissolution at the cathode. Additionally, HF complicates studying fundamental interfacial electrochemistry of Li-ion battery electrolytes, such as direct anion reduction, because it is electrocatalytically relatively unstable, resulting in a LiF passivation layer. Methods to selectively remove ppm levels of HF from LiPF6-containing carbonate-based electrolytes are limited. We introduce and benchmark a simple yet efficient electrochemical method to selectively remove ppm amounts of HF from LiPF6-containing carbonate-based electrolytes. The basic idea is the application of a suitable potential to a high surface-area metallic electrode upon which only HF reacts (electrocatalytically) while all other electrolyte components are unaffected under the respective conditions.</span></p> <p>&nbsp;</p>

opencc-by-4.0Mar 2024View details →
zenodo36/100

Data set related to the manuscript "Investigating the effect of particle size distribution and complex exchange dynamics on NMR spectra of ions diffusing in disordered porous carbons through a mesoscopic model"

<p>Graphical files in the agr format for all the figures in the manuscript entitled "Investigating the effect of particle size distribution and complex exchange dynamics on NMR spectra of ions diffusing in disordered porous carbons through a mesoscopic model". XYZ files giving the particles and bulk positions in the lattices are also provided.</p>

opencc-by-4.0May 2024View details →
zenodo36/100

Data set related to the manuscript "Investigating particle size effects on NMR spectra of ions diffusing in porous carbons through a mesoscopic model"

<p>Graphical files in the agr format for all the figures in the manuscript entitled &quot;Investigating particle size effects on NMR spectra of ions diffusing in porous carbons through a mesoscopic model&quot;. Examples of input files for the lattice simulations are also provided.</p>

opencc-by-4.0May 2023View details →
dryad32/100

Data from: Probabilistic interfractional motion carbon ion radiation therapy dose distribution for prostate cancer shows rectum sparing with moderate target coverage degradation

Purpose: This observational study investigates the influence of interfractional motion on clinical target volume (CTV) coverage, planning target volume (PTV) margins, and rectum tissue sparing in carbon ion radiation therapy (CIRT). It reports dose coverage to target structures and organs at risk in the presence of interfractional motion, investigates rectal tissue sparing, and provides recommendations for further lowering the rate of toxicity. We also propose probabilistic DVH for consideration in treatment planning to represent probable dose to the clinic's patient population. Methods: At Gunma University Hospital intensity-modulated x-ray therapy (IMXT, aka IMRT) prostate cancer patients are positioned on a table which is shifted twice based on cone-beam computed tomography (CBCT) to align bones and then align prostate tissue to isocenter. These shifts thereby contain interfractional motion. 1306 such tableshifts from 85 patients were collected. Normal probability distributions were fit to the difference between bone-matching and prostate-matching CBCT-to-planning CT tableshifts (i.e. interfractional motion). Between 2011 and 2016 CIRT prostate patients were treated with PTV1 and PTV2 margins as follows: PTV1 extends the prostate contour by 10/10, 5/10, 6/6 mm in the right/left, posterior/anterior, and superior/inferior directions, respectively, and the proximal seminal vesicles contour by 5 mm superiorly and inferiorly, 3 mm right and left. PTV2 reduces PTV1 posteriorly along a straight line to exclude the rectum and reduces the superior and inferior margins by 6 mm. From those treated with these margins, 40 patients' beam data were selected to create probable interfractional motion: The previously fit normal probability distributions were randomly sampled 2000 times per patient and beams shifted to simulate this motion. These shifted dose distributions were scaled down proportionately in magnitude and summed to obtain probable blurred dose distributions. Results: Probable dose to rectum is substantially less than planned for doses higher than 10 Gy(RBE). Absolute DVH show that mean clinical target volumes are about 138-670 cm3 smaller for a given probable dose than planned doses higher than 57 Gy(RBE) after accounting for standard error. Cumulative DVH show mean CTV fraction receiving a given probable dose is less than the mean fraction receiving the corresponding planned dose for doses larger than 52 Gy(RBE), up to 19% less at 57.4 Gy(RBE). Our PTV1 margins generally cover 95% of interfractional motion but seminal vesicles and inferior prostate receive less dose than planned due to insufficient PTV2 margins. Conclusion: Assuming rigidly shifting interfractional motion around the prostate region and neglecting minor changes in soft tissue stopping power, interfractional motion resulted in underdosing or tissue sparing in all cases. Given our low rates of relapse and recurrence, it appears less curative dose is needed than previously thought or else the target may be smaller than previously thought. In-room CT may be useful to lower dose, shrink target margins, conduct PET auto-activation dose verification studies and account for interfractional motion.

opencc-zeroDec 2017View details →
dryad32/100

Data from: Erythrocyte stiffness during morphological remodeling induced by carbon ion radiation

The adverse effect induced by carbon ion radiation (CIR) is still an unavoidable hazard to the treatment object. Thus, evaluation of its adverse effects on the body is a critical problem with respect to radiation therapy. We aimed to investigate the change between the configuration and mechanical properties of erythrocytes induced by radiation and found differences in both the configuration and the mechanical properties with involving in morphological remodeling process. Syrian hamsters were subjected to whole-body irradiation with carbon ion beams (1, 2, 4, and 6 Gy) or X-rays (2, 4, 6, and 12 Gy) for 3, 14 and 28 days. Erythrocytes in peripheral blood and bone marrow were collected for cytomorphological analysis. The mechanical properties of the erythrocytes were determined using atomic force microscopy, and the expression of the cytoskeletal protein spectrin-α1 was analyzed via western blotting. The results showed that dynamic changes were evident in erythrocytes exposed to different doses of carbon ion beams compared with X-rays and the control (0 Gy). The magnitude of impairment of the cell number and cellular morphology manifested the subtle variation according to the irradiation dose. In particular, the differences in the size, shape and mechanical properties of the erythrocytes were well exhibited. Furthermore, immunoblot data showed that the expression of the cytoskeletal protein spectrin-α1 was changed after irradiation, and there was a common pattern among its substantive characteristics in the irradiated group. Based on these findings, the present study concluded that CIR could induce a change in mechanical properties during morphological remodeling of erythrocytes. According to the unique characteristics of the biomechanical categories, we deduce that changes in cytomorphology and mechanical properties can be measured to evaluate the adverse effects generated by tumor radiotherapy. Additionally, for the first time, the current study provides a new strategy for enhancing the assessment of the curative effects and safety of clinical radiotherapy, as well as reducing adverse effects.

opencc-zeroDec 2013View details →
zenodo32/100

Spatial and longitudinal distributions of total carbon, nitrogen and sulphur together with water-soluble major ions in marine aerosols collected from the western Pacific and Southern Ocean

<p>Latitudinal ionic distributions are studied over the western Pacific (WP) and Southern Ocean (SO) to explore the sources and formation mechanism&nbsp;of major ions.</p>

opencc-by-4.0Mar 2023View details →
ClinicalTrials.gov32/100

Carbon Ion Radiotherapy for Primary Glioblastoma

ClinicalTrials.gov study NCT01165671. IPD Sharing: Not stated. Countries: 1. Publications: 1.

restrictedIPD-UNDECIDEDFeb 2026View details →
ClinicalTrials.gov32/100

Carbon-Ion Radiotherapy Plus Camrelizumab for Locally Recurrent Nasopharyngeal Carcinoma

ClinicalTrials.gov study NCT04143984. IPD Sharing: YES. Countries: 1. Publications: 1.

controlledIPD-YESFeb 2026View details →
ClinicalTrials.gov32/100

Clinical Study of Carbon Ion Radiotherapy for Pancreatic Cancer.

ClinicalTrials.gov study NCT06840067. IPD Sharing: NO. Countries: 1. Publications: 11.

closedIPD-NOFeb 2026View details →
ClinicalTrials.gov32/100

Carbon Ion Radiotherapy for Atypical Meningiomas

ClinicalTrials.gov study NCT01166321. IPD Sharing: Not stated. Countries: 1. Publications: 1.

restrictedIPD-UNDECIDEDFeb 2026View details →
ClinicalTrials.gov32/100

Clinical Study of Carbon Ion Radiotherapy for High-grade Glioma

ClinicalTrials.gov study NCT06831773. IPD Sharing: NO. Countries: 1. Publications: 11.

closedIPD-NOFeb 2026View details →
ClinicalTrials.gov32/100

Randomized Carbon Ions vs Standard Radiotherapy for Radioresistant Tumors

ClinicalTrials.gov study NCT02838602. IPD Sharing: Not stated. Countries: 1. Publications: 1.

restrictedIPD-UNDECIDEDFeb 2026View details →
ClinicalTrials.gov32/100

Trial of Proton Versus Carbon Ion Radiation Therapy in Patients With Low and Inter-mediate Grade Chondrosarcoma of the Skull Base

ClinicalTrials.gov study NCT01182753. IPD Sharing: Not stated. Countries: 1. Publications: 7.

restrictedIPD-UNDECIDEDFeb 2026View details →
ClinicalTrials.gov32/100

Treatment of Malignant Sinonasal Tumours With Intensity-modulated Radiotherapy (IMRT) and Carbon Ion Boost (C12)

ClinicalTrials.gov study NCT01220752. IPD Sharing: Not stated. Countries: 1. Publications: 16.

restrictedIPD-UNDECIDEDFeb 2026View details →
ClinicalTrials.gov32/100

Carbon Ion Radiotherapy for the Treatment of Localized Prostate Cancer

ClinicalTrials.gov study NCT02739659. IPD Sharing: Not stated. Countries: 1. Publications: 1.

restrictedIPD-UNDECIDEDFeb 2026View details →
ClinicalTrials.gov32/100

Functional Image-Guided Carbon Ion Irradiation With Simultaneous Integrated Boost for Prostate Cancer

ClinicalTrials.gov study NCT05010343. IPD Sharing: NO. Countries: 1. Publications: 1.

closedIPD-NOFeb 2026View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record