Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
16
datasets available to search
ShareScore release 0.9.0
Dataset results
16 results for “electrode array”
Surface electromyogram (sEMG) dataset recorded from forearm for 9 hand movements and three electrode array positions
<p>This repository contains raw surface Electromyography signals termed surface Electromyograms (<a href="https://en.wikipedia.org/wiki/Electromyography">sEMG</a>) recorded with 8 circular surface Ag/AgCl pairs of electrodes placed circumferentially around the forearm of the dominant arm in 10 able-bodied individuals (5 Females and 5 Males). The proposed method for processing sEMG data with subjects' characteristics and protocol can be found in <a href="https://doi.org/10.1016/j.bspc.2020.102292">Miljković & Isaković 2021</a>.</p> <p>For each subject, sEMG was recorded from <strong>three recording electrode array positions</strong> termed P1, P2, and P3 for 9 hand movements. We provide a compressed .7z folder with 10 sub-folders for each subject named by <strong>subject ID</strong> (ID1, ID2, ... ID10). Each sub-folder contains 27 .txt data files (for 9 movements × 3 electrode array positions), except for subject ID7 (there are 24 .txt records, since three records for wrist extension EX in P1, P2, and P3 positions got corrupted in subject ID7). Average size of 10 sub-folders is 167.50 ± 27.02 MB with maximum of 194 MB and minimum of 117 MB.</p> <p>The subjects performed following hand movements from the reference resting position –relaxation, R (explained in-detail in <a href="https://doi.org/10.1016/j.bspc.2020.102292">Miljković & Isaković 2021</a>): (1) spherical power grasp, PS, (2) three finger sphere grasp, 3F, (3) two finger prismatic grasp, PP, (4) wrist flexion, FL, (5) wrist extension, EX, (6) radial deviation, RD, (7) ulnar deviation, UD, and then forearm rotation i.e. (8) pronation, PR, and (9) supination, SU. PS, 3F, PP, FL, EX, RD, UD, PR, and SU correspond to <strong>type of hand movement</strong> in naming convention for .txt data files.</p> <p><a href="https://www.youtube.com/playlist?list=PLI3SYeiSufnBo6UDAZt9NJO9ecb-InJqb">Hand movements YoutTube playlist</a> contains explanatory videos for 9 hand movements recorded in this study, and we also provide corresponding .wmv here in the "movies hand movements.7z". Naming convention for .wmv files is <strong>type of hand movement</strong> with both full name and abbreviation for the movement (for example "radialDeviation-RD.wmv").</p> <p>Naming convention for .txt data files within 10 sub-folders is: <strong>subjects ID _ type of hand movement _ recording electrode array position</strong> (for example: "ID1_3F_P1.txt" in sub-folder ID1, "ID9_RD_P3.txt" in sub-folder ID9).</p> <p><strong>Dataset contents</strong></p> <ol> <li><a href="https://zenodo.org/record/4039550/files/EMG%20dataset.7z?download=1">EMG dataset.7z</a>, 267 .txt data files, text format</li> <li><a href="https://zenodo.org/record/4039550/files/movies%20hand%20movements.7z?download=1">movies hand movements.7z</a>, 9 .wmv files, explanatory hand movement videos (also available on <a href="https://www.youtube.com/playlist?list=PLI3SYeiSufnBo6UDAZt9NJO9ecb-InJqb">YouTube</a>)</li> <li><a href="https://zenodo.org/record/4039550/files/README.txt?download=1">README.txt</a>, metadata for data files, text format</li> </ol> <p><strong>Data files contain numerical values with decimal point* according to the following structure</strong></p> <ol> <li>column - CH1** (recorded samples from channel 1)</li> <li>column - CH2** (recorded samples from channel 2)</li> <li>column - CH3** (recorded samples from channel 3)</li> <li>column - CH4** (recorded samples from channel 4)</li> <li>column - CH5** (recorded samples from channel 5)</li> <li>column - CH6** (recorded samples from channel 6)</li> <li>column - CH7** (recorded samples from channel 7)</li> <li>column - CH8** (recorded samples from channel 8)</li> </ol> <p>* For subjects ID1 and ID2 three decimal places are provided, while for other subjects 6 decimal places in .txt data files are provided.</p> <p>** Each data file contains at least 10 repetitions of the corresponding movement. In cases where file contains >10 repetitions (overall 162 .txt data files), we used the first or the last ten for the analysis (except for two files where short and strong artifact appeared during the measurement procedure, and corresponding movement repetitions were discarded) presented in <a href="https://doi.org/10.1016/j.bspc.2020.102292">Miljković & Isaković 2021</a>.</p> <p>Sample rate was set at 1000 Hz and <a href="https://en.wikipedia.org/wiki/Analog-to-digital_converter">A/D card</a> had 16 bits resolution. Gain of the amplifier was set at 1000. For more in-detail explanations of electrode array assemble and positioning for sEMG channels CH1, CH2, ... CH8, please refer to <a href="https://doi.org/10.1016/j.bspc.2020.102292">Miljković & Isaković 2021</a>.</p> <p>If you find these signals useful for your own research or teaching class, please cite both relevant preprint and dataset as:</p> <ol> <li> <p>Miljković, N. and Isaković, M.S., 2021. Effect of the sEMG electrode (re) placement and feature set size on the hand movement recognition. <em>Biomedical signal processing and control</em>, 64:102292. <em><a href="https://doi.org/10.1016/j.bspc.2020.102292">10.1016/j.bspc.2020.102292</a></em></p> </li> <li> <p>Miljković, N. and Isaković, M.S., 2020. Surface electromyogram (sEMG) dataset recorded from forearm for 9 hand movements and three electrode array positions. [Data set]. <em>Zenodo</em> <em><a href="https://zenodo.org/record/4039550">10.5281/zenodo.4039550</a></em>.</p> </li> </ol> <p><strong>ACKNOWLEDGEMENTS</strong> (from <a href="https://doi.org/10.1016/j.bspc.2020.102292">Miljković & Isaković 2021</a>): "Special appreciation the authors owe to Professor Mirjana B. Popović from the University of Belgrade for her kind support,precious guidance, and advice regarding this research which significantly improved the manuscript. Also, the authors would like to thank Dr Matija Štrbac from Tecnalia Serbia Ltd. for providing advice throughout the study.The authors thank all volunteers for their participation."</p>
Multi-Electrode Array with a Planar Surface for Cell Patterning by Microprinting_experimental dataset
<p>This file contains the raw unprocessed experimental data for the results published in Slavík et al., Multi-Electrode Array with a Planar Surface for Cell Patterning by Microprinting, Sensors 2019, 19(24), 5379. </p>
Datasets for "Scalable, flexible carbon fiber electrode thread arrays for three-dimensional spatial profiling of neurochemical activity in deep brain structures of rodents"
<p>Datasets used in the manuscript titled, "<strong>Scalable, flexible carbon fiber electrode thread arrays for three-dimensional spatial profiling of neurochemical activity in deep brain structures of rodents</strong>" are uploaded here. </p> <p><strong>Brightfield and fluorescent stained images of brain tissue used for Fig. 5(a):</strong></p> <p>Malt3-20190624_Region 009_DAPI.png</p> <p>Malt3-20190624_Region 009_qCy5.png</p> <p>Malt3-20190624_Region 009_qFITC.png</p> <p>Malt3-20190624_Region 009_qTexasRed.png</p> <p>Malt3_BF20190628_Region 001.png</p> <p><strong>Fluorescent image of brain with embedded CFETs:</strong></p> <p>MALT2_Rat_100um_MOR1_x500_TSA_AF488.jpg</p> <p>Rat_100um_MOR1_x500_TSA.czi</p> <p><strong>In vivo dopamine recording data for Fig. 3:</strong></p> <p>ratarrays822_163.mat</p> <p>ratarrays822_57.mat</p>
Airbag-type Stretchable Electrode Array(ASEA) for Electrical Stimulation in Urinary Incontinence in Postmenopausal Women
ClinicalTrials.gov study NCT05506124. IPD Sharing: NO. Countries: 1. Publications: 4.
Scalar Localization Cochlear Electrode Array Using 64 Slice CT
ClinicalTrials.gov study NCT00587262. IPD Sharing: Not stated. Countries: 1. Publications: 1.
Cochlear Implant With Dexamethasone Eluting Electrode Array
ClinicalTrials.gov study NCT04750642. IPD Sharing: Not stated. Countries: 3. Publications: 0.
Data from: Multi-electrode array for transcutaneous lumbar posterior-root stimulation
Open the record for dataset details and reuse information.
Safety and Efficacy of a Drug Eluting Slim Modiolar Electrode Array
ClinicalTrials.gov study NCT06598059. IPD Sharing: NO. Countries: 1. Publications: 0.
First-in-human Experience Using Novel Ultraflexible Low-impedance Electrode Arrays: an IDEAL Stage 1 Study
ClinicalTrials.gov study NCT06116279. IPD Sharing: Not stated. Countries: 1. Publications: 0.
Can an Array of Micro-electrodes Implanted in a Human Nerve Record Neural Signals and Provide Feedback?
ClinicalTrials.gov study NCT05505513. IPD Sharing: Not stated. Countries: 1. Publications: 0.
Robotic-Assisted Versus Manual Electrode Array Insertion
ClinicalTrials.gov study NCT06951594. IPD Sharing: NO. Countries: 1. Publications: 0.
Long-term Follow-up of a Cochlear Implant With Dexamethasone Eluting Electrode Array
ClinicalTrials.gov study NCT06936449. IPD Sharing: NO. Countries: 1. Publications: 0.
Investigating the Neuronal Bases of Epilepsy With Micro-electrode Arrays in Candidates for Epilepsy Surgery
ClinicalTrials.gov study NCT02932839. IPD Sharing: UNDECIDED. Countries: 1. Publications: 0.
Transcriptomic differences in cochlear cells isolated from mice implanted with dexamethason-eluting electrode arrays or standard electrode arrays
GEO Series GSE282478. Mus musculus. 2 samples. Type: Expression profiling by high throughput sequencing.
Spatiotemporal Patterns of Gene Expression Around Implanted Silicon Electrode Arrays
GEO Series GSE254474. Rattus norvegicus. 48 samples. Type: Expression profiling by high throughput sequencing.
An electrochemical oscillatory flow reactor with pillar array electrodes improving mass transfer in electrosynthesis
<p>The folder contains the processed data of figures 2, 3, 4, 5, 6, & 7 that appear in:</p> <p>Vranckaert, M., Gemoets, H. P. L., Dangreau, R., van Aken, K., Breugelmans, T., & Hereijgers, J. (2022). An electrochemical oscillatory flow reactor with pillar array electrodes improving mass transfer in electrosynthesis. <em>Electrochimica Acta</em>, <em>436</em>(October), 141435</p>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.