Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
2
datasets available to search
ShareScore release 0.9.0
Dataset results
2 results for “restrictive filling pattern;”
Data set from Fantini F, Toso A, Menicanti L, Moroni F, Castelvecchio S. Restrictive filling pattern in ischemic cardiomyopathy: Insights after surgical ventricular restoration. J Thorac Cardiovasc Surg. 2019 Oct 30:S0022-5223(19)32349-9. doi: 10.1016/j.jtcvs.2019.09.173. Epub ahead of print. PMID: 31767363.
<p>Data set from Fantini F, Toso A, Menicanti L, Moroni F, Castelvecchio S. Restrictive filling pattern in ischemic cardiomyopathy: Insights after surgical ventricular restoration. J Thorac Cardiovasc Surg. 2019 Oct 30:S0022-5223(19)32349-9. doi: 10.1016/j.jtcvs.2019.09.173. Epub ahead of print. PMID: 31767363.</p> <p> </p> <p>This is the abstract:</p> <p><strong>Objective: </strong>To examine factors possibly involved in the resolution or persistence of restrictive filling pattern (RFP) after surgical ventricular restoration (SVR) in a series of patients with ischemic cardiomyopathy (ICM) and RFP.</p> <p><strong>Methods: </strong>Echocardiography was performed at baseline (pre-SVR), discharge, and follow-up in 43 patients with ICM and RFP (E/A ratio ≥2). Patients were divided into 2 groups based on E/A ratio at discharge: improved (E/A ratio <2; 22 patients) and unchanged (E/A ratio ≥2; 21 patients).</p> <p><strong>Results: </strong>The improved group had a significantly increased mean deceleration time (from 137 ± 22 ms to 194 ± 68 ms; P = .002) and mean A wave velocity (from 43 ± 10 cm/s to 92 ± 37 cm/s; P = .001), and decreased E/e' ratio (from 27.7 ± 9.5 to 19.2 ± 7.8; P = .01) after SVR. The unchanged group did not show any significant variations in diastolic parameters. The only significant differences at baseline between the two groups were thinner left ventricle posterior wall and lower relative wall thickness (RWT) in the unchanged group. RWT was the sole baseline parameter independently associated with persistent RFP.</p> <p><strong>Conclusions: </strong>RFP was reversed after SVR in 22 of our 43 patients with ICM with a response that remained stable over time, associated with improved New York Heart Association class. RWT was the sole baseline echocardiographic parameter significantly associated with the evolution of RFP after</p>
Restrictive filling pattern in ischemic cardiomyopathy: Insights after surgical ventricular restoration
<p>Dataset from Fantini F, Toso A, Menicanti L, Moroni F, Castelvecchio S. Restrictive filling pattern in ischemic cardiomyopathy: Insights after surgical ventricular restoration. J Thorac Cardiovasc Surg. 2021 Feb;161(2):651-660. doi: 10.1016/j.jtcvs.2019.09.173. Epub 2019 Oct 30. PMID: 31767363.</p> <p>Abstract</p> <p><strong>Objective: </strong>To examine factors possibly involved in the resolution or persistence of restrictive filling pattern (RFP) after surgical ventricular restoration (SVR) in a series of patients with ischemic cardiomyopathy (ICM) and RFP.</p> <p><strong>Methods: </strong>Echocardiography was performed at baseline (pre-SVR), discharge, and follow-up in 43 patients with ICM and RFP (E/A ratio ≥2). Patients were divided into 2 groups based on E/A ratio at discharge: improved (E/A ratio <2; 22 patients) and unchanged (E/A ratio ≥2; 21 patients).</p> <p><strong>Results: </strong>The improved group had a significantly increased mean deceleration time (from 137 ± 22 ms to 194 ± 68 ms; P = .002) and mean A wave velocity (from 43 ± 10 cm/s to 92 ± 37 cm/s; P = .001), and decreased E/e' ratio (from 27.7 ± 9.5 to 19.2 ± 7.8; P = .01) after SVR. The unchanged group did not show any significant variations in diastolic parameters. The only significant differences at baseline between the two groups were thinner left ventricle posterior wall and lower relative wall thickness (RWT) in the unchanged group. RWT was the sole baseline parameter independently associated with persistent RFP.</p> <p><strong>Conclusions: </strong>RFP was reversed after SVR in 22 of our 43 patients with ICM with a response that remained stable over time, associated with improved New York Heart Association class. RWT was the sole baseline echocardiographic parameter significantly associated with the evolution of RFP after SVR.</p>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.