60 results for “thermometer”
Molecular Thermometer Fig.2 - Dataset
<p>This is the data set used to generate Fig.2 in the paper https://doi.org/10.1103/PRXQuantum.4.040314</p>
Compilation of parallel measurements comparing the temperatures recorded in Stevenson screens with those recorded in pre-Stevenson screen thermometer exposures
<p>Compilation of parallel measurements comparing the temperatures recorded in Stevenson screens with those recorded in pre-Stevenson screen thermometer exposures. This dataset accompanies Wallis et al. (2024); further details of the dataset and its creation can be found in the attached readme file and Wallis et al. (2024).</p> <p>---</p> <p><strong>References</strong></p> <p>Wallis, E.J., Osborn, T.J., Taylor, M., Jones, P.D., Joshi, M. & Hawkins, E. (2024) Quantifying exposure biases in early instrumental land surface air temperature observations. <em>International Journal of Climatology, </em>https://doi.org/10.1002/joc.8401</p>
Daily temperature data at Adelaide, Australia taken in a Glaisher thermometer stand (1856–1952) and a homogenised daily temperature dataset for Adelaide (1856–2019)
<p>23000_Adelaide_Glaisherstand_Tx_data.tsv and 23000_Adelaide_Glaisherstand_Tn_data.tsv: Daily maximum and minimum temperature observations for Adelaide,South Australia, taken in a Glaisher thermometer stand from November 1856 to July 1947. Data are given in Station Exchange Format (SEF, https://github.com/C3S-Data-Rescue-Lot1-WP3/SEF/wiki).</p> <p>23000_combined_homogenised_data.tsv: A homogenised daily temperature dataset for Adelaide, South Australia, from January 1859 to December 2019. Data are provided in the format Year, Month, Day, Maximum temperature (degrees Celcius), Minimum temperature (degrees Celcius).</p> <p>Images of the data source for File 1 are available from the Australian Meteorological Association at https://www.met-acre.net/MERIT/AMETA.html. </p> <p>The data are shared under Attribution-NonCommercial 4.0 International licence (CC BY-NC 4.0)</p>
Going Above and Beyond: A Tenfold Gain in the Performance of Luminescence Thermometers Joining Multiparametric Sensing and Multiple Regression
<p>Dataset accompanying figures published in the publication DOI: https://doi.org/10.5281/zenodo.5930575</p>
Dataset related to publication "Non-contact thermometer for improved air temperature measurements"
<p>These datasets were used to produce Fig. 6, 8 and 9 in paper "Non-contact thermometer for improved air temperature measurements" to be published in <em>Sensors </em><strong>2023</strong><em>, 23. </em>The data were produced within the EMPIR project 18SIB01 GeoMetre.</p>
Making Nd3+ a Sensitive Luminescent Thermometer for Physiological Temperatures — An Account of Pitfalls in Boltzmann Thermometry
<p> Dataset accompanying figures published in the publication DOI: 10.3390/nano10030543</p>
Electromagnetic immune phosphor-tipped fibre-optic thermometers
<p>Calibration traceability can be broken where there are significant, unquantified uncertainties. Thermometry in harsh environments using electrical sensors, such as thermocouples or resistance thermometers, can be unpredictably affected by electro-magnetic sources. For this application, phosphor based temperature sensors with fibre-optic connection have been made following two different approaches – phosphor decay time changes and phosphor emission spectral changes – and tested by bombardment with high energy electrons and by measurements in large magnetic fields. Both sets of tests showed good immunity to exposure, and with magnetic field tests significantly better than a thermocouple. Phosphor thermometry therefore has potential to retain traceability in situations where conventional sensors might fail.</p>
From structural phase transition to highly sensitive lifetime based luminescent thermometer: multifaceted modification of thermometric performance in Y0.9xNdxYb0.1PO4 nanocrystals
<p>The development of a highly sensitive luminescent thermometer requires a deep understanding of the correlation between the structural properties of the host material and the temperature-dependent luminescence properties of lanthanide emitters embedded in these matrices. In some cases, the presence or increased concentration of the co-dopant ions can alter not only the spectral features, but may additionally cause far-ranging structural changes that further, even more tremendously, modify the luminescence properties of the phosphor. In this work, the temperature dependent luminescence kinetics in response to structural changes induced by increasing Nd<sup>3+</sup> ion doping in Y<sub>0.9−<em>x</em></sub>Nd<sub><em>x</em></sub>Yb<sub>0.1</sub>PO<sub>4</sub> nanocrystals are investigated, which correspondingly demonstrated phase transitions from xenotime to monazite structures. Consequently, the low temperature lifetime of the <sup>2</sup>F<sub>5/2</sub> state of Yb<sup>3+</sup> elongates. Moreover, by increasing the Nd<sup>3+</sup> amount, the relative sensitivity of the Yb<sup>3+</sup> luminescence lifetime-based luminescent thermometer was enhanced and, simultaneously, the temperature at which high sensitivity is achieved was reduced. The maximal relative sensitivity was found to be 2%/K at 273 K for Nd<sub>0.9</sub>Yb<sub>0.1</sub>PO<sub>4</sub> nanocrystals.</p>
The influence of the Er3+ dopant concentration in LaPO4:Nd3+, Er3+ on thermometric properties of ratiometric and kinetic-based luminescent thermometers operating in NIR II and NIR III optical windows
<p>In this work, properties of the near infrared absorbing and near infrared emitting Er<sup>3+</sup> and Nd<sup>3+</sup> co-doped LaPO<sub>4</sub> nanocrystals luminescent thermometer were investigated by exploiting luminescence spectra ratiometric and luminescence lifetime. The unique configuration of the energy levels of Nd<sup>3+</sup> and Er<sup>3+</sup> ions and the energy transfer between them requires temperature dependent phonon assistance. Since, the probability of this process is dependent on the distance between interacting ions, the thermometric parameters of luminescent thermometers were investigated as a function of Er<sup>3+</sup> dopant concentration. Strong susceptibility of its probability to temperature changes enables to quantify temperature with relative sensitivity as high as S<sub>R</sub> = 1.15%/K for LaPO<sub>4</sub>:1%Nd<sup>3+</sup>, 20%Er<sup>3+</sup> nanocrystals in the ratiometric approach and S<sub>R</sub> = 2.3%/K at 600 K for LaPO<sub>4</sub>:1%Nd<sup>3+</sup>, 5%Er<sup>3+</sup> in the luminescence lifetime based mode. The obtained results confirm the high applicative potential of this phosphor for remote temperature measurements.</p> <ul> </ul>
Metal-organic framework optical thermometer based on Cr3+ ions luminescence - data
<p><strong>Project NCN SONATA 16 2020/39/D/ST5/01289<br><br>Experimental data:</strong> Raman and diffuse reflectance spectra, band gap and crystal field strength, decay profiles and lifetimes, temperature-dependent luminescence and emission maps, thermometric parameters, exemplary system’s luminescent characteristics, unit cell characteristics, powder XRD data, Kubelka-Munk function with band gap estimation, excitation and emission spectra, stability of PL</p>
Perioperative Accuracy of the Raiing Wireless Axillary Thermometer
ClinicalTrials.gov study NCT02756910. IPD Sharing: NO. Countries: 1. Publications: 47.
Miniature iron-carbon eutectic point crucible for the calibration of thermometers
<p>The article presents the design, construction and evaluation of a miniature graphite iron-carbon eutectic point crucible for the calibration of thermometers. These are either contact such as thermocouples or non-contact such as infrared thermometers. The double wall of the crucible protects its structure in case of cracks in graphite that can appear due to thermal expansion or eutectic adhesion. Such design proved robust – even after almost 100 melting realizations, the crucible does not show significant signs of damage. Performance of the crucible was confirmed with several realized plateaus at three different furnace setpoints. Results of these measurements agree with previously published findings. The measured melting point temperature was 1153.81 °C and the achieved expanded calibration uncertainty of a type R thermocouple was 0.2 °C.</p>
A novel method for measuring sublingual temperature using conventional non-contact forehead thermometer
<p>Dataset includes :</p> <p>1. Data file - Excel spread sheet including recorded non contact sublingual recordings with corresponding tympanic temperature recordings.</p> <p>2.Consent form.</p>
Design, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C
<p>Dataset associated with publication DOI <a href="https://doi.org/10.1088/1361-6501/abee53">https://doi.org/10.1088/1361-6501/abee53</a></p>
Data from interlaboratory comparison of air thermometer calibrations, ATM ILC, 2019-2021
<p>The dataset contains data from an interlaboratory comparison conducted in EURAMET in 2019-2021, with the final report published in Oct 2023. The report and the ILC protocol are available in a different upload. </p> <p>This dataset consists of 3 files:</p> <ol> <li>participant information.xlsx: information on the setups used by each participant, their role in the ILC, temperatures measured at, the probes they measured on, the volume of chambers and the nature of the thermostat (bath, climate chamber or a subchamber).</li> <li>preprocessed data and drift.xlsx: preprocessed probe resistance, reference temperature, link corrected resistance, unilateral degree of equivalence, normalised error, pressure (if available), humidity (if available), pilot measurements in liquid and air for each probe, the list of points excluded from the consensus computations.</li> <li>selfheating.xlsx: probe-by-probe selfheating data from a number of participants (but not all). </li> </ol> <p> </p>
Validation of Faces Thermometer Scale (FTS)
ClinicalTrials.gov study NCT05322018. IPD Sharing: NO. Countries: 1. Publications: 11.
Comparison of Temperature Using Tracheal Thermometer and Pulmonary Artery Catheter in Adult Patients Undergoing CABG
ClinicalTrials.gov study NCT05595616. IPD Sharing: Not stated. Countries: 1. Publications: 1.
Accuracy of Zero-flux and Ingestible Thermometers
ClinicalTrials.gov study NCT02121574. IPD Sharing: Not stated. Countries: 1. Publications: 1.
The Use of a Distress Thermometer in a Pediatric Research Setting: An Exploratory Pilot Study
ClinicalTrials.gov study NCT00824278. IPD Sharing: Not stated. Countries: 1. Publications: 5.
Distress Thermometer Intervention Trial
ClinicalTrials.gov study NCT00960466. IPD Sharing: Not stated. Countries: 1. Publications: 2.
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.