Skip to main content
zenodoopen

Morphometric data from: Incongruent molecular and morphological variation in the crab spider Synema globosum (Araneae: Thomisidae) in Europe

<p>Here we provide the complete set of files used by <a href="https://doi.org/10.3897/zookeys.1078.64116">Urfer et al. (2021</a>, see References section below for the complete citation of the publication) for the morphometric and the molecular analysis. In particular, we provide the following documents:</p> <p><br> PART 1: MORPHOMETRIC ANALYSIS</p> <p>- 1_Synema_data_multiple_imputation_mice.R: R-script used for replacing NAs.</p> <p>- 1_Synema_data_NA_imputed.csv: Dataset with raw values (in millimeters) of all 28 specimens used for the morphometric analysis. Each specimen was measured 4 times. NAs replaced using the R-script &quot;Synema_multiple_imputation_mice.R&quot; above. This is the datafile used for all morphometric analyses.</p> <p>- 1_Synema_data_with_NA.csv: Dataset with raw values (in millimeters) of all 28 specimens. Each specimen was measured 4 times. NAs not replaced.<br> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;<br> - 1_Synema_Reliability.R: R-script for calculating reliability.<br> &nbsp;&nbsp; &nbsp;<br> - 1_Synema_Reliability_supplementary_figure.pdf: Results of reliability analysis presented in a bar plot.</p> <p>- 1_Synema_Reliability_supplementary_table.txt: Results of reliability analysis presented in a table.<br> &nbsp;&nbsp; &nbsp;<br> - 1_Synema_Shape_PCA_and_PCA_Ratio_Spectrum.R: R-script for calculating the shape PCA and the PCA Ratio Spectrum of the first shape PC. You may get the necessary MRA source script from http://doi.org/10.5281/zenodo.4250142<br> &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br> - Synema_globosum_AR9379_PV.jpg, Synema_globosum_AR9379_PV.jpg, Synema_globosum_AR9379_PV.jpg, etc.: Photographs taken with a LEICA M205 C stere-omicroscope.</p> <p>&nbsp;&nbsp;&nbsp; 1. Numbers after AR_ refer to the inventory number of the specimens in the Natural History Musuem Bern (NMBE). The specimen number was also used in the data file.<br> &nbsp;&nbsp;&nbsp; 2. The photo named &quot;Synema_globosum_AR9163_with_measurements&quot; shows the position of the measurements. Otherwise, the measurements are not indicated in the raw photos.</p> <p><br> Example image&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Character name&nbsp;&nbsp; &nbsp;Definition<br> Synema_globosum_AR9163_with_measurements&nbsp;&nbsp; &nbsp;cym.l&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Cymbium lenght&nbsp;&nbsp; &nbsp;Distance of the anterior margin to the tip of the cymbium<br> Synema_globosum_AR9163_with_measurements&nbsp;&nbsp; &nbsp;cym.b&nbsp;&nbsp; &nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;&nbsp;&nbsp; Cymbium breadth&nbsp;&nbsp; &nbsp;widest breadth of the cymbium<br> Synema_globosum_AR9163_with_measurements&nbsp;&nbsp; &nbsp;bul.b&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; Bulb breadth&nbsp;&nbsp; &nbsp;widest breadth of the genital bulbus<br> Synema_globosum_AR9163_with_measurements&nbsp;&nbsp; &nbsp;tib.b&nbsp;&nbsp; &nbsp;&nbsp;&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Tibia breadth&nbsp;&nbsp; &nbsp;breadth of the tibia base at the patella joint</p>

ShareScore

48/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
8
Access
20
Reuse readiness
8
Engagement
4

Topics