Skip to main content
zenodoopen

FDTD simulation of 290 nm PAAO with gold nanoparticles: varying incidence angle, s-polarization, n=1

<p>Version 2 has the same files as version 1 and some additional files.</p> <p>FDTD software: Lumerical (Ansys, version 2021 R2.3).</p> <p>Structure: aluminum (Palik) substrate; 290 nm thickness (<em>h</em>) aluminum oxide (Palik) layer with 35 nm diameter (<em>RPo</em>) cylindrical pores with 100 nm&nbsp;distance (<em>D</em>) between the pore centers (representing porous anodized aluminum oxide - PAAO); 60 nm diameter (<em>RNP</em>) gold (Johnson and Christy) nanoparticles placed directly above each pore.</p> <p>Refractive index of the surrounding medium (<em>n</em>): 1.0.</p> <p>Simulation region: from 300 nm below the substrate/PAAO interface to 1.3 &micro;m above PAAO surface; x and y spans are equal to one period of the structure.</p> <p>Mesh override region: from 50 nm below the PAAO to 50 nm above the nanoparticles; 2 nm step size in each direction.</p> <p>Light source: BFAST plane wave light source; 500 nm above PAAO; varying (20&deg; - 70&deg; in steps of 5&deg;) angle of incidence (<em>ang</em>); 300 nm &ndash; 1000 nm wavelength range; s-polarization (<em>pol</em>).</p> <p>Monitor (frequency domain field and power): 2D Z-normal; 1 &micro;m above PAAO; results are in &quot;<em>_reflection.txt</em>&quot; files.</p> <p>Information in the file name: <em>h</em> - thickness of PAAO; <em>pol</em> - polarization; <em>RNP</em> - diameter of gold nanoparticles; <em>RPo</em> - diameter of pores; <em>D</em> - distance between pore centers; <em>ang</em> - angle of incidence; <em>n</em> - refractive index of surrounding medium.</p> <p>Files: (1) &quot;<em>_reflection.txt</em>&quot; - lambda(nm) (first column) - wavelength in nanometers; Y (second column) - T data from the monitor above the structure. (2) &quot;<em>_p0.log</em>&quot; - log file produced by the software while running the simulation. (3) &quot;<em>.fsp</em>&quot; - Lumerical software file containing the simulation project (license required to open these files). Consecutive numbering corresponds to the angles of incidence: 1 - 20&deg;, 2 - 25&deg;, 3 - 30&deg;, 4 - 35&deg;, 5 - 40&deg;, 6 - 45&deg;, 7 - 50&deg;, 8 - 55&deg;, 9 - 60&deg;, 10 - 65&deg;, 11 - 70&deg;. (4) &quot;<em>Lumerical_Screenshots.pdf</em>&quot; - shows software screenshots for every object and its every property; red text is added to show which values are different for different simulations. (5) &quot;<em>Structure_Illustration.png</em>&quot; - a schematic of modeled structure. (6) &quot;290nm-Spol_varying-angle<em>.jpg</em>&quot; - a preview of data from &quot;<em>_reflection.txt</em>&quot; files.</p>

ShareScore

40/100

Overall dataset sharing score

Score breakdown

These five areas show where the dataset supports — or may limit — practical reuse.

Stewardship
8
Harmonization
4
Access
20
Reuse readiness
8
Engagement
0

Topics