Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
566
datasets available to search
ShareScore release 0.9.0
Dataset results
566 results for “Analytics”
Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays
<p>***ABSTRACT***</p> <p>_________________________</p> <p>The practice of monitoring therapeutic drug concentrations in patient biofluids can significantly improve clinical outcomes while simultaneously minimizing adverse side effects. A model example of this practice is vancomycin dosing in intensive care units. If dosed correctly, vancomycin can effectively treat methicillin-resistant staphylococcus aureus (MRSA) infections. However, it can also induce nephrotoxicity or fail to kill the bacteria if dosed too high or low, respectively. Although undeniably important to achieve effectiveness, therapeutic drug monitoring remains inconvenient in practice, due primarily to the lengthy process of sample collection, transport to a centralized facility, and analysis using costly instrumentation. Adding to this workflow is the possibility of backlogs at centralized clinical laboratories, which is not uncommon and may result in additional delays between biofluid sampling and concentration measurement, which can negatively affect clinical outcomes. Here we explore the possibility of using point-of-care, electrochemical aptamer-based (E-AB) sensors to minimize the time delay between biofluid sampling and drug measurement. Specifically, we conducted a clinical agreement study comparing the measurement outcomes of E-AB sensors to the benchmark automated competitive immunoassays for vancomycin monitoring in serum. Our results demonstrate that E-ABs are selective for free vancomycin—the active form of the drug—over total vancomycin. In contrast, competitive immunoassays measure total vancomycin, including both protein-bound and free drug. Accounting for these differences in a pilot study consisting of 85 clinical samples, we demonstrate that the E-AB vancomycin measurement achieved a 95% positive correlation rate with the benchmark immunoassays. Therefore, we conclude that E-AB sensors could provide clinically useful stratification of patient samples at trough sampling to guide effective vancomycin dose recommendations.</p> <p> </p> <p>***README FILE ***</p> <p>_________________________</p> <div>Project: Analytical Validation of Aptamer-Based Serum Vancomycin Monitoring Relative to Automated Immunoassays</div> <div>Date Accepted: December 5th, 2023</div> <div>DOI: </div> <div>Contact: Netz Arroyo, netzarroyo@jhmi.edu</div> <div> </div> <div>ORGANIZATION</div> <div> </div> <div>All files in this repository are sorted based on their corresponding figure in the associated manuscript</div> <div>and supplementary information document (both found at DOI above). Organization and files found in each figure folder </div> <div>are as follows:</div> <div> </div> <div>- 'Figure_1':</div> <div>- Final .svg image for Figure 1.</div> <div> </div> <div>- 'Figure_2':</div> <div>-"Figure_2.png"</div> <div>- PNG image of Figure 2. Figure panels were generated as detailed in the following entries. Figure was compiled in Adobe Illustrator. </div> <div>-"swv trace.svg"</div> <div>- SVG file for Panel C. Generated using Igor Pro v8 from data in file "SWV Traces.pxp".</div> <div>-"ON&OFF.svg"</div> <div>- SVG file for Panel D . Generated using Igor Pro v8 from data in file "Signal ON&OFF.pxp". </div> <div>-"ratio box whisker plot.svg"</div> <div>- SVG file for Panel E. Generated using Igor Pro v8. </div> <div>-"calibration.svg"</div> <div>- SVG file for Panel F. Generated using Igor Pro v8. </div> <div>-Data: "SWV Traces.xlsx"</div> <div>"SWV Traces.csv"</div> <div>"SWV Traces.pxp" </div> <div>Data was obtained from sheet "SWV curves" of Excel file "ZiO-JHU_March 2023_Data processing Updates" recieved 10:37 EST, June 2 2023, from Yu Liu. </div> <div>Data was used as recieved, and imported to Igor Pro v8 for plotting. Data in all files are identical, except for file format.</div> <div>-Data: "Signal ON&OFF.xlsx"</div> <div>"Signal ON&OFF.csv"</div> <div>"Signal ON&OFF.pxp" </div> <div>Data was obtained from sheet "signal-on&signal-off" of Excel file "ZiO-JHU_March 2023_Data processing Updates" recieved 10:37 EST, June 2 2023, from Yu Liu. </div> <div>Data was used as recieved, and imported to Igor Pro v8 for plotting. Data in all files are identical, except for file format. Regression to the Hill equation</div> <div>was performed in Igor Pro v8, constraining rate=1.</div> <div>-Data: "Dose response curve box plot.xlsx"</div> <div>"Dose response curve box plot.csv"</div> <div>"Dose response curve box plot.pxp" </div> <div>Data was obtained from sheet "Curve fitting_Ratio(SUM_MEA)" of Excel file "ZiO-JHU_March 2023_Data processing Updates" recieved 10:37 EST, June 2 2023, from Yu Liu. </div> <div>Data was used as recieved, and imported to Igor Pro v8 for plotting. Data in all files are identical, except for file format. Box and whisker plot was generated using</div> <div>Igor Pro v8.</div> <div>-Data: "Day1-Day6 Dose Response Curve.xlsx"</div> <div>"Day1-Day6 Dose Response Curve.csv"</div> <div>"Day1-Day6 Dose Response Curve.pxp" </div> <div>Data was obtained from sheet "Curve fitting_Ratio(SUM_MEA)" of Excel file "ZiO-JHU_March 2023_Data processing Updates" recieved 10:37 EST, June 2 2023, from Yu Liu. </div> <div>Data was used as recieved, and imported to Igor Pro v8 for plotting. Data in all files are identical, except for file format. Nonlinear regression to the Hill equation</div> <div>was generated using Igor Pro v8. No variables were constrained.</div> <div> </div> <div>-'Figure_3':</div> <div>- DATA FOR FIGURE 3 WAS OBTAINED FROM THE "Ratiometric response" SHEET OF THE FILE "Confidential_ZiO Health Stability Test Data" RECIEVED 12:08, NOVEMBER 8 2023, FROM FRANCESCA NAPOLI.</div> <div>- DATA FROM FIELDS "Average response to 12.5 mg/L for chips tested in specific week" AND "SD response to 12.5 mg/L for chips tested in specific week" (ROWS 39 AND 40) , WITH ASSOCIATED TIMEPOINT IDENTIFIERS, WERE EXTRACTED AND USED AS RECIEVED</div> <div>- IN ROWS 41 AND 42, DATA FROM THE 0.1 MG/L CONCENTRATION POINT (ROW 13) WAS EXCTRACTED AND PROCESSED IN THE SAME WAY AS "Average response to 12.5 mg/L for chips tested in specific week" AND "SD response to 12.5 mg/L for chips tested in specific week" (I.E, AVERAGE AND STANDARD DEVIATION OF THREE OR FOUR CHIPS PER WEEK)</div> <div>- TIMEPOINT IDENTIFIERS WERE CONVERTED TO NUMERIC AND GIVEN THE TITLE "Time" and UNIT "Weeks"</div> <div>- FIELD "Average response to 12.5 mg/L for chips tested in specific week" WAS TITLED "12.5 mg/L Sensor response ratio" AND GIVEN UNIT "360Hz/20Hz"</div> <div>- FIELD "SD response to 12.5 mg/L for chips tested in specific week" WAS TITLED "12.5 mg/L SD" AND GIVEN UNIT "360Hz/20Hz"</div> <div>- THE SAME WAS DONE FOR THE 0.1 MG/l CONCENTRATION DATA</div> <div>- DATA FILE USED FOR MAKING THE FIGURE IS "2023_11_08_Chip_Stability.pxp"</div> <div>- BOTH O.1 MG/L AND 12.5 MG/L WERE SUBJECTED TO LINEAR REGRESSION ANALYSIS IN IGOR V8</div> <div> </div> <div>-'Figure_4':</div> <div>- Final PNG image for Figure 4.</div> <div> </div> <div>-'Figure_5':</div> <div>- "2023_11_07_Fig5.png"</div> <div>- Final .PNG file used for Figure 5. Panels were arranged and Mean/StDev numbers were added in Adobe Illustrator.</div> <div>- "EAB_diff.svg"</div> <div>-.svg file used for panel A of Figure 5. Generated in Igor v8.</div> <div>- "EAB_pct_aveplot.svg"</div> <div>-.svg file used for panel C of Figure 5. Generated in Igor v8.</div> <div>- "ImA_diff.svg"</div> <div>-.svg file used for panel B of Figure 5. Generated in Igor v8.</div> <div>- "ImA_pct_aveplot.svg"</div> <div>-.svg file used for panel D of Figure 5. Generated in Igor v8.</div> <div>- Data: "2023_07_10_Differentials.xlsx"</div> <div>"2023_07_10_Differentials.csv"</div> <div>"2023_07_10_Differentials.pxp"</div> <div>Data was obtained from sheet "Predict con.c" of Excel file "ZiO-JHU_March 2023_Data processing Updates" recieved 10:37 EST, June 2 2023, from Yu Liu. </div> <div>Data was used as recieved, and imported to Igor Pro v8 for plotting. </div> <div>-'Figure_6':</div> <div>- "2023_07_12_Fig6.png"</div> <div>- Final .PNG file used for Figure 6. Panels were arranged and statistics valued added in Adobe Illustrator.</div> <div>- "serum.svg"</div> <div>-.svg file used for panel A of Figure 5. Generated in Igor v8 from Table 0.</div> <div>- "Filtrate smaller points.svg"</div> <div>-.svg file used for panel C of Figure 5. Generated in Igor v8 from Graph 0.</div> <div>- "Filtrate_insert.svg"</div> <div>-.svg file used for panel B of Figure 5. Generated in Igor v8 from Graph 5.</div> <div>- "Bland-Altman.svg"</div> <div>-.svg file used for panel D of Figure 5. Generated in Igor v8 from Graph 1.</div> <div>- "Bland-Altman insert.svg"</div> <div>-.svg file used for panel D of Figure 5. Generated in Igor v8 from Graph 1.</div> <div>- "Rplot0_png.png"</div> <div>-.png file of Bangdiwala plot. Generated in Rstudio by code mentioned below.</div> <div>- "Agreement plot code.txt"</div> <div>-Code used to generate Bangdiwala agreement plot using Rstudio. </div> <div>- Data: "Concentrations_all.xlsx"</div> <div>"Concentrations_all.csv"</div> <div>Data was obtained from sheet "Predict con.c" of Excel file "ZiO-JHU_March 2023_Data processing Updates" recieved 10:37 EST, June 2 2023, from Yu Liu. </div> <div>Data was used as recieved, and imported to Igor Pro v8 for plotting. </div> <div>- Data: "Bland-Altman.xlsx"</div> <div>"Bland-Altman.csv"</div> <div>Data was obtained from sheet "Bland–Altman Plot" of Excel file "ZiO-JHU_March 2023_Data processing Updates" recieved 10:37 EST, June 2 2023, from Yu Liu. </div> <div>Data was used as recieved, and imported to Igor Pro v8 for plotting. </div> <div>- Data: "ROC-input data for agreement plot.xlsx"</div> <div>"ROC-input data for agreement plot.csv"</div> <div>Data was recieved 12:30 EST, December 7 2023, from Francesca Napoli.</div> <div>- Data: "Fig6.pxp"</div> <div>Table 0: all samples from "Concentrations_all.xlsx"</div> <div>Table 1: average and difference values for EA-B filtrate samples vs immunoassay filtrate samples from "Bland-Altman.xlsx", as well as upper and lower 95% CI boundaries</div> <div>Table 2: samples sorted by concentration and filtered by immunoassay values <15mg/L and <10mg/L.</div> <div>Graph 0: plot of immunoassay vs E-AB serum concentration values from Table 0.</div> <div>Graph 1: plot of immunoassay vs E-AB filtrate concentration values from Table 0.</div> <div>Graph 2: plot of average vs difference values from Tablel 1.</div> <div>Graph 4: plot of filtered immunoassay vs E-AB filtrate concentration values <10mg/L from Table 3.</div> <div>Graph 5: plot of filtered immunoassay vs E-AB filtrate concentration values <15mg/L from Table 3.</div> <div> </div> <div> </div> <div>NOTES</div> <div> </div> <div>(1) Raw voltammetry data is the property of ZiO Health, and is therefore not available for public release. All data presented here were extracted from raw voltammetric traces by ZiO Health,</div> <div>and transfered to the Arroyo lab for further analysis. </div> <div> </div> <div>(2) RStudio is available at: https://posit.co/products/open-source/rstudio/</div> <div> </div> <div>(3) Igor Pro is available at: https://www.wavemetrics.com/</div> <div> </div>
Code for "An analytical study of bifurcation-free rapid learning in a short-term memory task"
Open the record for dataset details and reuse information.
LAPARO Analytic vs. Classic Box Trainer on Laparoscopic Skills Training
ClinicalTrials.gov study NCT07081386. IPD Sharing: NO. Countries: 0. Publications: 0.
Analytical Treatment Interruption in a Patient With HIV Post Allogeneic Stem Cell Transplantation From a CCR5 delta32 Homozygous Donor
ClinicalTrials.gov study NCT06582797. IPD Sharing: NO. Countries: 0. Publications: 0.
Analytical Performance of pH, HNE and MPO Levels in Detecting Wound Infection Proof of Concept Biomarker Study
ClinicalTrials.gov study NCT04979637. IPD Sharing: Not stated. Countries: 0. Publications: 0.
Pre-analytical factors affecting the establishment of a single tube assay for multi-parameter liquid biopsy detection in melanoma patients
GEO Series GSE143231. Homo sapiens. 58 samples. Type: Non-coding RNA profiling by high throughput sequencing.
Experimental and Analytical Development of a Health Management System for Electro-Mechanical Actuators
Expanded deployment of Electro-Mechanical Actuators (EMAs) in critical applications has created much interest in EMA Prognostic Health Management (PHM), a key enabling technology of Condition Based Maintenance (CBM). As such, Impact Technologies, LLC is collaborating with the NASA Ames Research Center to perform a number of research efforts in support of NASA’s Integrated Vehicle Health Management (IVHM) initiatives. These efforts have combined experimental test stand development, laboratory seeded fault testing, and physical model-based health monitoring in a comprehensive PHM system development strategy. This paper discusses two closely related EMA research programs being conducted by Impact and NASA Ames. The first of these efforts resulted in the creation of an electro-mechanical actuator test stand for the Prognostics Center of Excellence at the NASA Ames Research Center. The second effort is ongoing and is utilizing physics-based modeling techniques to develop an algorithm and software package toolset for PHM of aircraft EMA systems using a hybrid (virtual sensor) approach.
Analytical performance of OncoPrism-HNSCC, an RNA-based assay to inform immune checkpoint inhibitor treatment decisions for recurrent/metastatic head and neck squamous cell carcinoma
GEO Series GSE270047. Homo sapiens. 434 samples. Type: Expression profiling by high throughput sequencing.
Dataset used in Design Analytics for Mobile Learning: Scaling up theClassification of Learning Designs based onCognitive and Contextual Elements
<p>The following dataset has been used for the paper entitled "Design Analytics for Mobile Learning: Scaling up theClassification of Learning Designs based onCognitive and Contextual Elements".</p> <p>Abstract</p> <p>This research was triggered by the identified need in literature for large-scale studies about the kind of designs that teachers create for Mobile Learning (m-learning). These studies require analyses of large datasets of learning designs. The common approach followed by researchers when analysing designs has been to manually classify them following high-level pedagogically-guided coding strategies, which demands extensive work. Therefore, the first goal of this paper is to explore the use of Supervised Machine Learning (SML) to automatically classify the textual content of m-learning designs, through pedagogically-relevant classifications, such as the cognitive level demanded by students to carry out specific designed tasks, the phases of inquiry learning represented in the designs, or the role that the situated environment has in them. As not all the SML models are transparent, while often researchers need to understand the behaviour behind them, the second goal of this paper considers the trade-off between models’ performance and interpretability in the context of design analytics for m-learning. To achieve these goals we compiled a dataset of designs deployed through two tools, Avastusrada and Smartzoos. With it, we trained and compared different models and feature extraction techniques. We further optimized andcompared the best-performing and most interpretable algorithms (EstBERT and Logistic Regression) to consider the second goal through an illustrative case. We found that SML can reliably classify designs, with accuracy>0.86and Cohen’s kappa>0.69.</p>
Social Media Big Dataset for Research, Analytics, Prediction, and Understanding the Global Climate Change Trends
<p>Yuriy Syerov, October 6, 2023, "Social Media Big Dataset for Research, Analytics, Prediction, and Understanding the Global Climate Change Trends", IEEE Dataport, doi: https://dx.doi.org/10.21227/71ms-8v86</p> <p>https://ieee-dataport.org/documents/social-media-big-dataset-research-analytics-prediction-and-understanding-global-climate</p>
Dynamic Quantitative Analytic Response of Human Natural Killer Cells at Single-Cell Resolution in B-cell Non-Hodgkin Lymphoma
GEO Series GSE102930. Homo sapiens. 21 samples. Type: Expression profiling by array.
What’s wrong with SwYG? Probing the limits of S. cerevisiae molecular and analytical toolbox
GEO Series GSE190122. Saccharomyces cerevisiae. 6 samples. Type: Expression profiling by high throughput sequencing.
Impact of pre-analytical handling on neuroblastoma cells mRNA gene expression
GEO Series GSE63294. Homo sapiens. 9 samples. Type: Expression profiling by array.
Advanced analytical electron microscopy applied to Solid Oxide Cell materials and their degradation - Result Scripts
<p>The data set consist in 4 compressed folders: one is the Fiji script (ESEM movie maker) used in my thesis to obtain video from ESEM images and three are python notebooks (Data extraction and synchronization, Hyperspy EDS Analysis, Diffusion simulation) also used in my thesis. Data are also provided to test the script and notebooks.</p> <p>Appendix F and G from the thesis can also be downloaded here.</p> <p>Appendix F (User guide of the Fiji script): guidelines for using the script written for post-acquisition processing of environmental scanning electron microscopy images.<br> <br> Appendix G(User guide of python notebook): guidelines for using the python notebook to display interactively mass spectrometer signals. Notebook 1 (Data extraction and synchronization): Processing the EDX data from STEM and SEM thanks to the Hyperspy library. Notebook 2 (Hyperspy EDS Analysis): processing the MS data in order to allow a clear visualisation and an easier interpretation thanks to interactive plots using the Bokeh library. Notebook 3 (Diffusion simulation): Simulating the interdiffusion between cobalt and iron thanks to the Pydiffusion library.</p>
Advanced analytical electron microscopy applied to Solid Oxide Cell materials and their degradation .- Result Movies
<p>This set of movies illustrates and complements my PhD thesis "Advanced analytical electron microscopy applied to Solid Oxide Cell materials and their degradation " conducted at Ecole Polytechnique Fédérale de Lausanne. The movies were obtained after alignment of images resulting from the observation of solid oxide cell material exposed to high temperature in an environmental scanning electron microscope.</p> <p>In the file name, chapter and section numbers are written to help the reader make the link between the video and the thesis. <br> The name of the sample is written in every file name.<br> If the movie refers to a specific figure in the thesis, the figure number is also added to the file name.<br> Optionally, the subject of the movie can be specified (particularly when several movies are related to the same sample).</p> <p><br> The appendix A of the thesis (Summary table) is also added so the conditions in which the movies were recorded can be easily found.</p>
Round or rectangular tables for collaborative problem solving? A multimodal learning analytics study
<p>This dataset contains the necessary details to reproduce the experiments of the paper :</p> <p>Vujovic M., Hernández-Leo, D., Tassani S., Spikol D. (2020). Round or rectangular tables for collaborative problem solving? A multimodal learning analytics study, (in the process of revision) <em>British Journal of Education Technology</em></p> <p>This data represents measurements collected from two experiments explained in the article:</p> <ul> <li>Qualitative data - observations</li> <li>Experiment_university students - measurements (distance between students, range of movement, level of participation)</li> <li>Experiment_elementary school students - measurements (distance between students, range of movement, level of participation)</li> </ul> <p>We would appreciate it if you cite the paper after using the dataset.</p>
Data from: Effectiveness of Computerized Cognitive Training Programs (CCTP) with Game-like Features in Children with or without Neuropsychological Disorders: a Meta-Analytic Investigation
<p>Computerized cognitive training programs (CCTP) are based on the assumption that cognitive abilities may be boosted by repetitively performing challenging tasks. The integration of game-like features in these programs, associated with the goal of amusing or rewarding participants, may contribute to generate cognitive benefits. Indeed, reinforcement contingencies have been reported to produce positive effects on performance and motivation, especially in children. This meta-analysis was aimed at providing a quantitative summary of the effectiveness of CCTP with game-like features in school-aged children with typical and atypical development. A total of 24 studies, with the cognitive and behavioral outcome data of 1547 participants, were selected for inclusion in the meta-analysis. Subgroup analyses were performed to identify the sources of the observed methodological heterogeneity. A robust variance estimation model, after removal of study outliers, yielded a small-to-moderate significant effect size. Final results pointed out smaller but more precise estimate effect sizes according to methodological aspects related to cognitive domain of outcomes, standardization of measures and type of control applied. Alongside supporting the use of CCTP for rehabilitating cognitive functions, the present results shed light on how different methodological choices are able to shape research findings in the field of children's cognitive rehabilitation.</p>
Dataset for "Analytical and clinical performances of seven direct detection assays for SARS-CoV-2"
<p>This dataset represent raw data for the unpublished article "Analytical and clinical performances of seven direct detection assays for SARS-CoV-2".</p>
Experimental dataset: TEMPERATURE DEPENDENCE ON STOCHATIC DYNAMIC DIFFUSION COEFFICIENTS OF HEATED ELECTROSPRAY IONIZATION AND ATMOSPHERIC PRESSURE CHEMICAL IONIZATION MASS SPECTROMETRIC INTENSITIES OF ANALYTE IONS OF CONFIGURATIONALLY LOCKED POLYENES – THEORY AND EXPERIMENT
<p>Experimental dataset of heated electrospray ionization and atmospheric pressure chemical ionization mass spectra of configurationally locked polyenes. The dataset is empirical proof of the validity of our new model equation connecting among the stochatic dynamic diffusion parameter, the temperature and the mass spectrometric measurable variable 'intensity' of an observable peak of analyte ion.</p>
Popular but hardly used: Has Google Analytics been to the detriment of Web Analytics (Dataset)
<p>This is the data used for the paper "Popular, but hardly used: Has Google Analytics been to the detriment of Web Analytics?", to be presented at Web Science 23.</p>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.