Skip to main content
ConductScienceScienceDex
Powered by ShareScore

Find research datasets worth reusing

Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.

13,800

datasets available to search

ShareScore release 0.9.0

Reset

Dataset results

13,800 results for “teste”

Learn how ShareScore rates datasets ↗
zenodo44/100

Original Recording of Freiburg Words for Testing Hearing with Speech

<p>The files contain recordings of the monosyllabic words, polysyllabic numbers, and CCITT noise (ITU, 1993) of the Freiburg Speech Test (Hahlbrock, 1953). The words are given in DIN 45621-1:1995. The 400 monosyllables are organized in 20 test lists à 20 nouns. They are stored in "Einsilbige Wörter.zip". The name of each wav-file includes the number of the test list (L01, L02, …) and the position of the word within the test list (W01, W02, …). The 100 polysyllables are organized in 10 test lists à 10 numbers. They are stored in "Mehrsilbige Wörter (Zahlen).zip" with similar nomenclature. DIN 45626-1:1995 describes the recordings. Speech signals were recorded in 1969 in the studios of Norddeutscher Rundfunk, Hamburg, Germany, with the speaker Claus Wunderlich (Brinkmann, 1974). The recordings were processed by Physikalisch-Technische Bundesanstalt, Braunschweig, Germany, and Polygram International, Hannover, Germany. Later, the recordings were digitalized by Siemens AG and distributed on compact disc by "Siemens Audiologische Technik GmbH" (legal successor WS Audiology A/S) with the title "Wörter für Gehörprüfung mit Sprache" ("Words for hearing tests with speech") under item no. 7970155. The words were cut out as accurately as possible, i.e., with as little background before and after each word as possible (see Winkler and Holube, 2016a). The CCITT noise was originally included for calibration purposes, but is often used as noise masker when the monosyllables are presented in background noise.</p>

opencc-by-4.0Nov 2023View details →
zenodo44/100

Training and test datasets for the PredictONCO tool

<p>This dataset was used for training and validating the <a href="https://loschmidt.chemi.muni.cz/predictonco/">PredictONCO </a>web tool, supporting decision-making in precision oncology by extending the bioinformatics predictions with advanced computing and machine learning. The dataset consists of 1073 single-point mutants of 42 proteins, whose effect was classified as Oncogenic (509 data points) and Benign (564 data points). All mutations were annotated with a clinically verified effect and were compiled from the ClinVar and OncoKB databases. The dataset was manually curated based on the available information in other precision oncology databases (The Clinical Knowledgebase by The Jackson Laboratory, Personalized Cancer Therapy Knowledge Base by MD Anderson Cancer Center, cBioPortal, DoCM database) or in the primary literature. To create the dataset, we also removed any possible overlaps with the data points used in the PredictSNP consensus predictor and its constituents. This was implemented to avoid any test set data leakage due to using the PredictSNP score as one of the features (see below).</p> <p>The entire dataset (<strong>SEQ</strong>) was further annotated by the pipeline of PredictONCO. Briefly, the following six features were calculated regardless of the structural information available: essentiality of the mutated residue (yes/no), the conservation of the position (the conservation grade and score), the domain where the mutation is located (cytoplasmic, extracellular, transmembrane, other), the PredictSNP score, and the number of essential residues in the protein. For approximately half of the data (<strong>STR</strong>: 377 and 76 oncogenic and benign data points, respectively), the structural information was available, and six more features were calculated: FoldX and Rosetta ddg_monomer scores, whether the residue is in the catalytic pocket (identification of residues forming the ligand-binding pocket was obtained from P2Rank), and the pKa changes (the minimum and maximum changes as well as the number of essential residues whose pKa was changed &ndash; all values obtained from PROPKA3). For both&nbsp;<strong>STR </strong>and <strong>SEQ </strong>datasets, 20% of the data was held out for testing.&nbsp;The data split was implemented at the position level to ensure that no position from the test data subset appears in the training data subset.&nbsp;</p> <p>For more details about the tool, please visit the <a href="https://loschmidt.chemi.muni.cz/predictonco/help">help page</a> or <a href="https://loschmidt.chemi.muni.cz/peg/contact/">get in touch with us</a>.</p> <p>14-Dec-2023 update: the file with features<em> PredictONCO-features.txt</em> now includes UniProt IDs, transcripts, PDB codes, and mutations.</p>

opencc-by-4.0Oct 2023View details →
zenodo44/100

Datasets with typos for testing LEA (https://arxiv.org/abs/2307.02912)

<p>Datasets for testing the generalization capacity of LEA in the presence of typos. Link to the paper: https://arxiv.org/abs/2307.02912</p> <p>Below is a list of raw public datasets and different versions of test splits to which automatically synthetically generated typos have been added by deleting and replacing characters.</p> <ul> <li>Abt-Buy</li> <li>Amazon-Google</li> <li>WDC-Computers (small, medium, large and xlarge)</li> <li>WDC-All (xlarge)</li> <li>RTE</li> <li>MRPC</li> </ul> <p>&nbsp;</p> <p>Reference:</p> <p>Almagro, M., Almaz&aacute;n, E., Ortego, D., &amp; Jim&eacute;nez, D. (2023, August). LEA: Improving Sentence Similarity Robustness to Typos Using Lexical Attention Bias. In&nbsp;<em>Proceedings of the 29th ACM SIGKDD Conference on Knowledge Discovery and Data Mining</em> (pp. 36-46).</p>

opencc-by-4.0Dec 2023View details →
zenodo44/100

Qiime2 classifiers (rbcl, Mollusc 18s) for testing the validity of using eDNA for carbon origin analysis from sediment cores

<p>Qiime2 formatted classifiers that were created for a Natural England funded project by researchers at the James Hutton Institute. The pilot project aims to test the validity of using eDNA for carbon origin analysis from sediment cores. These classifiers for the rbcl and 18 Mollusc genes were made using RESCRIPt and Qiime2.&nbsp;</p> <p>The scripts used to created these classifiers are available at the James Hutton ICS GitHub <a href="https://github.com/HuttonICS/blue-carbon-db">blue-carbon-db</a> . The files are as follows:</p> <p><a href="../api/records/10046481/draft/files/mollusc-espineira-classifier.qza/content" target="_blank" rel="noopener noreferrer">mollusc-espineira-classifier.qza</a> is a classifer built from ncbi 18s Mollusc sequences, trained on the primer set from Espi&ntilde;eira et al (2009).</p> <div>rbcl-vasselon-zimmerman-F3-R1-classifier.qza is a classifer built from ncbi rbcl sequences, trained on the F3 and R1 primer set fromVasselon et al (2017).</div> <p>&nbsp;</p> <p>&nbsp;</p> <p><strong>Important: </strong>If you use these classifiers please be aware of the process used to create them and be sure to review the methods. These databases were created by downloading data from the NCBI in October 2023, sequence data available at the NCBI changes over time. To create the most up to date database a fresh download and re-evaluations of the databases would be preferable. All method and scripts can be found at <a href="https://github.com/HuttonICS/blue-carbon-db">blue-carbon-db&nbsp;</a></p> <p>If you use these database please reference this repository along with RESCRIPt and Qiime2&nbsp;</p> <p>&nbsp;</p> <p>Espi&ntilde;eira, M., Gonz&aacute;lez-Lav&iacute;n, N., Vieites, J. M. and Santaclara, F. J. 2009 Development of a method for the genetic identification of commercial bivalve species based on mitochondrial 18S rRNA sequences. J Agric Food Chem, 28, 495-502 https://doi.org/10.1021/jf802787d</p> <p>&nbsp;</p> <p>Vasselon, V., Rimet, F., Tapolczai, K. and Bouchez, A. 2017. Assessing ecological status with diatoms DNA metabarcoding: Scaling-up on a WFD monitoring network (Mayotte island, France). Ecological Indicators, 82, 1-12 <a title="Persistent link using digital object identifier" href="https://doi.org/10.1016/j.ecolind.2017.06.024" target="_blank" rel="noreferrer noopener">https://doi.org/10.1016/j.ecolind.2017.06.024</a></p>

opencc-by-4.0Mar 2024View details →
zenodo44/100

Investigating the ageing process of polymer modified bitumen using a modified Thin-Film Oven Test in the aspect of recycling purpose within Weave-UNISONO 2021 project, NCN project No 2021/03/Y/ST8/00079

<div><strong>Summary:</strong></div> <div>One polymer-modified bitumen PMB 25/55-60 was tested in two stages: original and after the modified Thin-Film Oven Test (TFOT). The time ranges from 1h-5h, and temperatures from 120&deg;C-200&deg;C were used. The Fourier-Transform Infrared (FTIR) Spectroscopy and Dynamic Shear Rheometer (DSR) with parallel plates were conducted. Test temperatures range from 30&ndash;70&deg;C for a 25 mm diameter plate and 0&ndash;30&deg;C for an 8 mm plate with 10&deg;C intervals and angular frequency range of 0.1, 1.0, and 10 Hz.</div> <div>&nbsp;</div> <div>&nbsp;</div> <div><strong>The dataset includes:</strong></div> <div>Basic characteristics of bituminous binder (R&amp;B Temperatur, Penetration), CSV raw data:</div> <div> <ul> <li>01 - SP Pen.csv</li> </ul> </div> <div>&nbsp;</div> <div>Dynamic shear rheometer (Temperatures 0-70 &deg;C, Angular Frequency 0.1Hz, 1.0Hz, 10 Hz, Complex Shear Modulus, Phase Angle):</div> <ul> <li>02.1 - DSR Rheology_Unaged.csv</li> <li>02.2 - DSR Rheology_2h_140C.csv</li> <li>02.3 - DSR Rheology_2h_200C.csv</li> <li>02.4 - DSR Rheology_5h_140C.csv</li> <li>02.5 - DSR Rheology_5h_200C.csv</li> </ul> <div>&nbsp;</div> <div>FTIR - Fourier-Transform Infrared Spectroscopy&nbsp;</div> <div> <ul> <li>OPUS Spectroscopy files.zip</li> </ul> </div> <div>&nbsp;</div> <div>---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; --- &nbsp;---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---</div> <div>to open the OPUS files, please go to the &copy; Bruker webpage and download the free OPUS Viewer.</div> <div>https://www.bruker.com/en/products-and-solutions/infrared-and-raman/opus-spectroscopy-software/downloads.html</div> <div>---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; --- &nbsp;---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---&nbsp; ---</div> <div>&nbsp;</div>

opencc-by-4.0Dec 2023View details →
zenodo44/100

Database of Uniaxial Shaking Table Tests for a Two-Storey Steel-Frame Structure

<h2>Description:</h2> <p>This data set contains data from experiments conducted on a two-storey steel-frame structure, involving sine-sweep, white noise, impulse, and earthquake loading. The experiments were carried out using a uniaxial shaking table of the <a href="https://www.lbb.rwth-aachen.de/go/id/eaxh/">Institute of Structural Analysis and Dynamics (LBB) - RWTH Aachen University</a>, in cooperation with the <a href="https://www.stb.rwth-aachen.de/cms/~iozv/STB/">Institute of Structural Steel (STB) - RWTH Aachen</a> and the <a href="https://www.cwe.rwth-aachen.de/home-2/">Center for Wind and Earthquake Engineering (CWE) &ndash; RWTH Aachen</a>.</p> <h3>Test structure:</h3> <p>The test structure was a two-storey, single-bay moment resisting frame (MRF) in the direction of excitation. In the perpendicular direction, a concentrically braced system provided lateral stability. The dimensions of the test structure were: 2.40 m length, 2.40 m width, and 3.78 m total height. Each floor had a distinct height: 2.02 m for the first floor and 1.76 m for the second. The moment resisting connections were realized as bolted extended unstiffened endplate joints. The column web panel was strengthened by two supplementary web plates (SWP) and continuity plates (CP). The base plate was meticulously modified to allow for rotation movement in order to approximate a pinned boundary condition. In addition, diaphragm action was ensured using diagonally arranged L-profiles in the plane of each floor.&nbsp;For additional mass, four steel I-profiles, each weighting 1650 kg were attached to the main structure (2 on each floor) and were secured by using steel U-profiles. &nbsp;An industrial pressure vessel with a self-weight of 100 kg, which remained empty for the first phase of the experimental campaign, was additionally mounted on the first floor.&nbsp;</p> <p>The properties of the frame structure are:</p> <ul> <li>Columns: HEA200 S355-J2 + 2 SWP + 6 CP</li> <li>Beams: HEA160 S235-JR</li> <li>Bolts: 8x M16, 10.9 HV</li> <li>Joints: Partial strength, semi-rigid</li> <li>End-plate: 272x190x8 mm</li> <li>Welds: Full penetration groove welds</li> </ul> <h3>Test setup:</h3> <p>The shaking table specifications are:</p> <ul> <li>Table size: 3.0x3.0 m</li> <li>Max. specimen mass: 10 t</li> <li>Max. overturning moment: 30 m t</li> <li>Max. actuator stroke: +/- 250 mm</li> <li>Max. table velocity: +/- 1 m/s at rated load</li> <li>Max. table acceleration: +/- 1g at rated load</li> <li>Test frequency: 0 to 50 Hz</li> </ul> <p>The instrumentation scheme of the test setup consisted mainly of accelerometers, displacement tranducers and strain gauges, measuring the excitation provided by the shaking table and the response of the structure. Regarding the global response of the test structure, the recordings of the accelerometers and displacement tranducers indicated in the uploaded file 'Instrumentation_Scheme_v1.0.0.pdf' are provided.&nbsp;</p> <p>The properties of the accelerometers are:</p> <ul> <li>Type: M3701-series</li> <li>Manufacturer: PCB Piezotronics, Inc.</li> <li>Measurement range: +/- 3g</li> <li>Frequency range: 0-500 Hz</li> <li>Sensitivity: 900 mV/g</li> <li>Resolution: 2.2e-5g</li> <li>Noise: 1&nbsp;&micro;g/Hz<sup>-0.5</sup></li> </ul> <p>The properties of the displacement tranducers are:</p> <ul> <li>Type: LZW-M-500</li> <li>Manufacturer: WayCon Positionsmesstechnik GmbH</li> <li>Measurement range: +/- 250 mm</li> <li>Linearity: +/- 0.05%</li> <li>Repeatability: 0.01 mm</li> <li>Displacement force: &le;15 N</li> <li>Displacement speed: &le;5 m/s</li> </ul> <h2>Files:</h2> <ul> <li>Load_Protocols_v1.0.0.pdf <ul> <li>.pdf file listing all load protocols applied to the structure.</li> </ul> </li> <li>Time_Histories_v1.0.0.pdf <ul> <li>.pdf file displaying the acceleration and displacement time histories according to the load protocols.</li> </ul> </li> <li>Data_v1.0.0.zip <ul> <li>Contains all data files according to the load protocols.</li> <li>The experimental data is provided as .csv files for each load protocol. The experiments are named by the load protocol. A .pdf file contains the corresponding data plots.</li> </ul> </li> <li>References_v1.0.0.bib <ul> <li>Contains a bibtex reference with the associated publications.</li> </ul> </li> <li>Shake_Table.jpg <ul> <li>Photo of the shaking table without any specimen.</li> </ul> </li> <li>Test_Structure_v1.0.0.jpg <ul> <li>Photo of the shaking table including the test structure.</li> </ul> </li> <li>Test_Structure_Sketch_v1.0.0.pdf <ul> <li>.pdf file illustrating the test structure.</li> </ul> </li> <li>Instrumentation_Scheme_v1.0.0.pdf <ul> <li>.pdf file illustrating the sensor placements on the test structure.</li> </ul> </li> </ul> <h2>File format of the data sets:</h2> <p>The data is stored in .csv files, where each file contains the following columns:</p> <ul> <li>Time: Time in seconds since the start of the test (time step equals 0.003 s).</li> <li>Acc_0: Acceleration signal measured in m/s<sup>2</sup> on the shaking table.</li> <li>Acc_1: Acceleration response of the structure measured in m/s<sup>2</sup> on the first floor.</li> <li>Acc_2: Acceleration response of the structure measured in m/s<sup>2</sup> on the second floor.</li> <li>Disp_0: Displacement signal measured mm on the shaking table.</li> <li>Disp_1: Displacement response of the structure measured in mm on the first floor.</li> <li>Disp_2: Displacement response of the structure measured in mm on the second floor.</li> </ul> <p>These data files can easily be uploaded using the pandas library in Python. For example by:</p> <pre><code>import pandas as pd df = pd.read_csv('LP01_Sweep_001.csv') time = df["Time"] acc_0 = df["Acc_0"] disp_0 = df["Disp_0"]</code></pre> <h2>Contact:</h2> <p>Please send your enquiries regarding the shaking table to <a href="dynamics@lbb.rwth-aachen.de">dynamics@lbb.rwth-aachen.de</a>. Further information can be found on our <a href="https://www.lbb.rwth-aachen.de/go/id/eaxh/">website</a>.</p> <h2>Usage/License:</h2> <ul> <li>The data is licensed under CC BY-SA 4.0.</li> <li>If you have used our data and are publishing your work, we ask you to please reference both <ul> <li>this database by its DOI, and</li> <li>any publication that is associated with the experiments. See the "References_v1.0.0.bib" for the associated publication references.</li> </ul> </li> </ul> <h2>Fundings:</h2> <ul> <li>Deutsche Forschungsgemeinschaft - <em>Grant number: INST 222/1161-1 FUGG</em>. Einaxialer Schwingtisch f&uuml;r dynamische Modell- und Bauteilversuche.</li> <li>Bundesministerium f&uuml;r Bildung und Forschung - <em>Grant number: 03G0892A</em>. ROBUST &ndash; Nutzerorientiertes Erdbebenfr&uuml;hwarnsystem mit intelligenten Sensorsystemen und digitalen Bauwerksmodellen &ndash; Entwicklung Installation und Anwendung von sensorbasierten Monitoringsystemen mit BIM-Integration zur Echtzeit-Schadenerkennung in kritischen Infrastrukturen.</li> </ul> <p>&nbsp;</p>

opencc-by-sa-4.0Nov 2023View details →
zenodo44/100

In search of a conditioned place preference test to assess the severity of experimental procedures

<p>This deposit contains the choice dataset belonging to the publication with the title "In search of a conditioned place preference test to assess the severity of experimental procedures".&nbsp;</p> <p>A preprint version of the paper will be published on bioRxiv.</p> <p>The data set contains:</p> <ul> <li>for the Conditioned Place Preference Tests 1-9: table of time stamps with the position of the mice during the habituation and the final test</li> <li>a txt-file containing a rough description of the columns and their meanings</li> <li>the R Script which was used to analyze the data tables, especially with regard to statistics</li> </ul> <p>For more details on methods and results please read the manuscript.</p>

opencc-by-nc-sa-4.0Apr 2024View details →
zenodo44/100

scelda test data

<p>20210323_4i4color_149x25</p> <p><strong>m1a_features.csv</strong></p> <p>No imagenet features.</p> <p>columns 0-1 spatial x, y coordinates</p> <p>columns 2-16 morphological features: area, area_bbox, area_convex, area_filled, axis_major_length, axis_minor_length, eccentricity, equivalent_diameter_area, euler_number, extent, feret_diameter_max, orientation, perimeter, perimeter_crofton, solidity</p> <p>columns 17-24 protein mean intensity: GFAP, ELAVL2, LMN1b, MBP, LMN1b_5, GFAP_5, MBP_5, ELAVL2_5</p> <p>cells were segmented using LMN1b stain using cellpose2&nbsp;</p> <p><strong>m1a_celltypes.csv</strong></p> <p>cell types determined using CCA in Seurat</p>

opencc-by-4.0Apr 2024View details →
zenodo44/100

Data set of a thermal response test on a planar trench collector

<p>This data set provides three different temperature measurements (PT100, fiber optic measurement, thermistors), as well as the determination of the volumetric water content and the bulk electrical conductivity of the subsurface. During the published period, a thermal response test was carried out. On April 28th, at 15:25, the fluid circulation began, and heat injection started at 15:38 on April 28th and continued until May 3rd. The test was conducted with a constant volume flow of 1.00 m&sup3;/h and a constant heat injection rate of 0.88 kW.</p>

opencc-by-4.0Nov 2024View details →
zenodo44/100

DATASET: TESTING NICHE EQUIVALENCE IN AMPHIDROMOUS FISH POPULATIONS

<p>Presence records of<em> Galaxias maculatus</em> were collected from 12 locations across five river basins in central-southern Chile during March, May, August, and November of 2019 as part of a study on fish sampling and processing (Ram&iacute;rez-&Aacute;lvarez et al. 2022. doi.org/10.1038/s41598-022-06936-8)</p> <p>Isotopic niches defined using a standard ellipse area (SEAc) in isotopic space, represented by a 2D ellipsoidal space (&delta;13C - &delta;15N) (see Supporting Information: Standard ellipse area functions - Ram&iacute;rez-&Aacute;lvarez et al. 2024. doi:10.1007/s10750-024-05738-5) - Empirical Bayesian Kriging</p> <p>Database of varibles used for niche modelling: isotopic niche and seven abiotic variables selected from 23 predictor variables: (1) 19 climate variables representing 1950&ndash;2000 climate averages from WorldClim (http://www.worldclim.org/). (2) Four spatially continuous topographic and hydrological variables from the EarthEnv Project adjusted to the HydroSHEDS river network (http://www.earthenv.org/) (Domisch et al. 2015). Selection of variables was accomplished by analysis of covariance and multicollinearity, using the ENMeval R package (Muscarella et al. 2014): (1) principal component analysis (PCA) to explore relationships among all predictors, evaluating the composition of components (component variables) that accounted for &ge;65% of variance explained, (2) pairwise comparisons &nbsp;to detect pairs of variables with strong correlations (Pearson correlation coefficients &lt;0.8), groups with a correlation of less than 0.8 were considered independent, and (3) variance inflation factor (VIF) &lt;10, to reduce the effect of collinearity between predictors (Listed below). A VIF greater than 10 indicates collinearity problems in the model. The vifcor and vifstep functions were employed by calculating two different strategies to exclude highly collinear variables using a stepwise procedure (Muscarella et al. 2014).</p> <div><em>Variable description and ecological question associated, selected variables are marked in bold.</em></div> <div><em>Series 1: Temperature, temperature variations and interaction with precipitation.</em></div> <div>bio1: Annual Mean Temperature; Is the temperature usually suitable?&nbsp;</div> <div><strong>bio2: Mean Diurnal Range; Are the days too warm or too cold?</strong></div> <div>bio3: Isothermality; Do temperatures fluctuate greatly over the course of a month?&nbsp;</div> <div>bio4: Temperature Seasonality (standard deviation); Do temperatures fluctuate greatly over the course of a year?</div> <div>bio5: Min Temperature of Coldest Month; Is the maximum temperature too high?</div> <div>bio6: Min Temperature of Coldest Month; Is the temperature constantly too high?</div> <div><strong>bio7: Temperature Annual Range; Do temperatures fluctuate greatly over the course of a year?</strong></div> <div><strong>bio8: Mean Temperature of Wettest Quarter; Is it too cold or too warm during the rainy season?</strong></div> <div>bio9: Mean Temperature of Driest Quarter; Is it too cold or too warm during the dry season?</div> <div>bio10: Mean Temperature of Warmest Quarter; Are the warmer months too cold?</div> <div><strong>bio11: Mean Temperature of Coldest Quarter; Are the colder months too warm?</strong></div> <div><em>Series 2: Precipitation and Rainfall Patterns</em></div> <div>bio12: Annual Precipitation; Does it rain enough in a year?</div> <div>bio13: Precipitation of Wettest Month; Does it rain a lot during the wettest month?</div> <div><strong>bio14: Precipitation of Driest Month; Does it rain poorly during the driest month?</strong></div> <div>bio15: Precipitation Seasonality (Coefficient of Variation); Would rainfall fluctuate much between seasons?</div> <div>bio16: Precipitation of Wettest Quarter; Does it rain a lot in the rainy season?</div> <div>bio17: Precipitation of Driest Quarter; Is rainfall low during dry seasons?</div> <div>bio18: Precipitation of Warmest Quarter; Does it rain enough during the warmer months?</div> <div>bio19: Precipitation of Coldest Quarter; Does it rain enough during the colder months?</div> <div><em>Series 3: Topology and hydrology</em></div> <div><strong>dem: Average elevation; Does altitude play a role as a topological factor?</strong></div> <div><strong>slope_av: Average slope; Is the slope suitable for the accumulation of small ponds?</strong></div> <div>flow_ac_ac: Accumulation flow; Does enough water accumulate or does it drain too quickly?</div> <div>flow_ac_le: Accumulation flow direction; Does the flow direction support the formation of small ponds?</div> <p>Domisch, S., G. Amatulli &amp; W. Jetz, 2015. Near-global freshwater-specific environmental variables for biodiversity analyses in 1&thinsp;km resolution. Scientific Data 2(1):150073 doi:10.1038/sdata.2015.73.</p> <p>Muscarella, R., P. J. Galante, M. Soley‐Guardia, R. A. Boria, J. M. Kass, M. Uriarte &amp; R. P. Anderson, 2014. ENM eval: An R package for conducting spatially independent evaluations and estimating optimal model complexity for Maxent ecological niche models. Methods in ecology and evolution 5(11):1198-1205</p>

opencc-by-4.0Nov 2024View details →
zenodo44/100

Wind tunnel test data for the evaluation of the aerodynamic coefficients of an antenna mast with ancillaries.

<p>This dataset comprises measured data and results from static wind tunnel tests conducted in April 2024 at the Giovanni Solari Wind Tunnel Facility (GS-WinDyn). The tests aim to assess the drag, lift, and moment coefficients <span>of an antenna mast designed as a triangular lattice tower, equipped with both linear and discrete ancillary components.</span> The wind tunnel experiments are carried out under both smooth and turbulent flow conditions using a scaled 3D model of the antenna mast. Five ancillary configurations, based on predominant patterns observed, are tested. Drag forces, lift forces and moments are measured using two six-component force balances attached to the ends of the model, while downstream three-component velocity data is captured by a Cobra probe. For each configuration, aerodynamic coefficients are determined for angles of attack ranging from 0&deg; to 360&deg;, with increments of up to 10&deg;. The dataset provides the measured data and the obtained aerodynamic coefficients and it has significant reuse potential in several applications: comparison with experimental wind tunnel data, validation of analytical and numerical CFD models with similar configurations, estimation of wind loads due to ancillary structures, and characterization of wake effects.</p>

opencc-by-4.0Dec 2024View details →
zenodo44/100

Gold standard for tractograms and meshes io testing

<p>Gold standard for tractograms (<em>trk, tck, trx, dpy, vtk, fib</em>) and meshes (<em>gii, pial, vtk, ply, stl, obj</em>) IO testing for the StatefulTractogram (SFT) and StatefulSurface (SFS) in Dipy.</p>

opencc-by-4.0Apr 2019View details →
zenodo44/100

A data set from an extensive experimental benchmark study of the Hell Bridge Test Arena subject to imposed damage

<p>A data set from an extensive experimental benchmark study of the Hell Bridge Test Arena (HBTA), a full-scale steel bridge subject to imposed damage, has been established. The data set includes organized dynamic response and load measurement data of the bridge under different structural state conditions, where the structural state conditions range from an undamaged (reference) state to known damage states. Furthermore, the data set includes acceleration and strain data from the response monitoring and acceleration data from the load monitoring, where a modal vibration shaker is used as an excitation source. The data is collected in one h5-file (hierarchical data format version 5) with a sampling rate of 100 Hz. Signal processing and resampling of the data has been performed according to the description provided in the references below. The data set is now published in this open-access data repository and can be accessed and downloaded freely. As such, the data set provides an important benchmark to the scientific community within bridge damage detection and SHM.</p>

opencc-by-4.0Jan 2024View details →
zenodo44/100

Open data repository, Knab et al., Prediction of stroke outcome in mice based on non-invasive MRI and behavioral testing

<p><strong>Open data repository,&nbsp;Knab et al., Prediction of stroke outcome in mice based on non-invasive MRI and behavioral testing</strong></p> <p><strong>Latest version of files: repository_v2.0.zip, Behavior Data_v2.0.xlsx and MRI IDs Testing&amp;Replication Cohort.xlsx (please ignore repository.zip)</strong></p> <p>Open data repository Knab et al. Prediction of stroke outcome in mice based on non-invasvive MRI and behavioral testing</p> <p>Open code and documentation of prediction models available via&nbsp;<a href="https://github.com/major-s/mouse-mcao-outcome-predictor">https://github.com/major-s/mouse-mcao-outcome-predictor</a></p> <p><strong>Content:</strong></p> <p>README.txt</p> <p>This information</p> <p><strong>dat</strong></p> <p>Contains MRI data in NIFTI format and secondary data from atlas registration. For documentation of atlas registration files see https://pubmed.ncbi.nlm.nih.gov/28829217/<br>Files used for the manuscript:<br>t2.nii: t2 weighted image acquired 24 h post stroke<br>masklesion.nii: manually delineated lesion<br>x_masklesion.nii: lesion in atlas space<br>ix_ANO.nii: Allen brain atlas in native space (i.e. matching t2.nii)<br>Lesion volume was calculated by volume of voxels unequal 0 in x_masklesion.nii<br>Overlap of regions defined by ix_ANO.nii with masklesion.nii were used for calculating percent damage in each atlas region</p> <p><strong>prediction_models</strong></p> <p>Contains separated training and test data as xlsx and csv files with lesion volumes in cubic mm of the Allen brain atlas space, percent damage per atlas region and behavioral data. The training data was used as input for training prediction models in MATLAB, the results were created using the test data.<br>The files have following sturcture:<br>Column 1: animal ID<br>Columns 2-537: MRI regions (column title corresponds to the region number as used in the Allen common coordinate framework)<br>Column 538: lesion volume<br>Column 539: initial performance (subacute deficit) = mean performance/deficit on days 2-6<br>Column 540: mean performance/deficit on days 2-6 = initial performance (subacute deficit) - this column equals column 539 but has different header which was used to train the residual from initial deficit<br>Column 541: residual performance/deficit<br>Column 542: test or training group<br>Consecutive rows contain data for each animal specified by the animal id</p> <p>The repository also contains all trained models, prediction results for the test data and tables with resulting median absolute error (MedAE) and 5th, 25th, 75th and 95 absolute error quantiles for each model.<br>The model files end with '_models.mat' and contain 50 independently trained models each. Each model version is specified by number 1-50.<br>The result files end with '_test_results.mat' or '_test_results.xlsx', files with MedAE and quantiles end with '_test_errors.xlsx' or '_test_errors.csv. The common part of filenames specifies the used paradigm<br>Folder 'subacute deficit prediction' contains:<br>&nbsp;- initial_performance_from_lesion_volume: prediction of subacute deficit using lesion volume<br>&nbsp;- initial_performance_from_segmented_mri: prediction of subacute deficit using segmented mri<br>Folder 'long-term outcome prediction' contains:<br>&nbsp;- lesion_volume: prediction of residual deficit using lesion volume<br>&nbsp;- segmented_mri: prediction of residual deficit using segmented_mri<br>&nbsp;- initial_performance: prediction of residual deficit using subacute deficit<br>Folder 'mri_inc_oob_imp' contains models trained using increasing number of mri segments sorted according to the out-of-bag importance. &nbsp;The number of used segments is given in the file name. The models, results and errors are separated in subfolders.</p> <p>Files with equal file name and different extension always contain the same data</p> <p><strong>templates</strong><br>Allen atlas, template, brain mask, hemisphere masks, tissue probability masks in NIFTI format including annotations of region IDs and parameter.m file for use in MATLAB toolbox ANTx2<br>&nbsp;</p>

opencc-by-4.0May 2022View details →
zenodo44/100

Extended dataset for the validation the competent Computational Thinking test in grades 3-6

<p>Extended dataset for the validation the competent Computational Thinking test in grades 3-6<br>=======================================================</p> <p>&bull; If you publish material based on this dataset, please cite the following :</p> <p>&nbsp;&nbsp; &nbsp;&bull; The Zenodo repository : Laila El-Hamamsy, Barbara Bruno, Jessica Dehler Zufferey, &amp; Francesco Mondada (2023). Extended dataset for the validation of the competent Computational Thinking test in grades 3-6 [Data set]. Zenodo. https://doi.org/10.5281/zenodo.7983525&nbsp;</p> <p>&nbsp;&nbsp; &nbsp;&bull; The article on the validation of the computational thinking test for grades 3-6 : El-Hamamsy, L., Zapata-C&aacute;ceres, M., Mart&iacute;n-Barroso, E., Mondada, F., Zufferey, J. D., Bruno, B., &amp; Rom&aacute;n-Gonz&aacute;lez, M. (2025). The competent Computational Thinking test (cCTt): A valid, reliable and gender-fair test for longitudinal CT studies in grades 3&ndash;6.&nbsp;<em>Technology, Knowledge and Learning</em>, 1-55. &nbsp;https://doi.org/10.1007/s10758-024-09777-8&nbsp;</p> <p>&bull; License : This work is licensed under a Creative Commons Attribution 4.0 International license (CC-BY-4.0)</p> <p>&bull; Creators : El-Hamamsy, L., Bruno, B., Dehler Zufferey, J., and Mondada, F.</p> <p>&bull; Date May 30th 2023</p> <p>&bull; Subject : Computational Thinking (CT), Assessment, Primary education, Psychometric validation</p> <p>&bull; Dataset format : CSV. The dataset contains four&nbsp;files (one per grade, see detailed description below). Please note that the spreadsheets may contain missing values due to students not being present for a part of the data collection. To have access to the specific cCTt questions please refer to the original publication [1] and Zenodo repository [2] which provide the full set of questions and correct responses.</p> <p>&bull; Dataset size &lt; 500 kB</p> <p>&bull; Data collection period : January and November 2021</p> <p>&bull; Abbreviations :<br>&nbsp; - CT : Computational Thinking<br>&nbsp; - cCTt: competent CT test</p> <p>&bull; Funding : This work was funded by the the NCCR Robotics, a National Centre of Competence in Research, funded by the Swiss National Science Foundation (grant number 51NF40_185543)</p> <p># References</p> <p>[1] El-Hamamsy, L., Zapata-C&aacute;ceres, M., Barroso, E. M., Mondada, F., Zufferey, J. D., &amp; Bruno, B. (2022). The Competent Computational Thinking Test: Development and Validation of an Unplugged Computational Thinking Test for Upper Primary School. Journal of Educational Computing Research, 60(7), 1818&ndash;1866. https://doi.org/10.1177/07356331221081753&nbsp;</p> <p>[2] El-Hamamsy, L., Zapata-C&aacute;ceres, M., Marcelino, P., &nbsp;Dehler Zufferey, J., Bruno, B., Mart&iacute;n Barroso, E., &amp; ‪Rom&aacute;n-Gonz&aacute;lez, M.‬ (2022). Dataset for the comparison of two Computational Thinking (CT) test for upper primary school (grades 3-4) : the Beginners' CT test (BCTt) and the competent CT test (cCTt) (Version 1) [Data set]. Zenodo. https://doi.org/10.5281/zenodo.5885034 ‬‬‬‬‬‬‬‬‬‬‬</p> <p>[3] El-Hamamsy, L., Zapata-C&aacute;ceres, M., Mart&iacute;n-Barroso, E.&nbsp;<em>et al.</em>&nbsp;The Competent Computational Thinking Test (cCTt): A Valid, Reliable and Gender-Fair Test for Longitudinal CT Studies in Grades 3&ndash;6.&nbsp;<em>Tech Know Learn</em> (2025). https://doi.org/10.1007/s10758-024-09777-8</p> <p>[4] Brennan, K. and Resnick, M. (2012). New frameworks for studying and assessing the development of computational thinking. page 25</p> <p>[5] El-Hamamsy, L., Zapata-C&aacute;ceres, M., Marcelino, P., Bruno, B., Dehler Zufferey, J., Mart&iacute;n-Barroso, E., &amp; Rom&aacute;n-Gonz&aacute;lez, M. (2022). Comparing the psychometric properties of two primary school Computational Thinking (CT) assessments for grades 3 and 4: The Beginners&rsquo; CT test (BCTt) and the competent CT test (cCTt). Frontiers in Psychology, 13. https://www.frontiersin.org/articles/10.3389/fpsyg.2022.1082659</p>

opencc-by-4.0Dec 2022View details →
zenodo44/100

Helsinki Deblur Challenge 2021 test dataset

<p>This dataset was primarily designed and captured to be used for the testing part of the Helsinki Deblur Challenge 2021 but it can be used for any testing and benchmarking purposes of image deblurring algorithms.</p> <p>The dataset contains photographs of&nbsp;random strings of text (including numbers), natural images and QR codes&nbsp;with varying levels of blur caused by misfocusing the camera. Each photo has both a blurred and sharp version.</p> <p>The images are split into 4 separate zip files each having 5 steps of different blur. Altogether there are 20 steps. Each one of the&nbsp;zip files contains two&nbsp;folders,&nbsp;one folder named CAM1_focused (Camera 1) with the sharp images and one named CAM2_blurred (Camera 2) with the&nbsp;blurred images. For each step there are 40&nbsp;images of&nbsp;text character targets, 15 natural image targets,&nbsp;one QR-code target and 3 images of technical targets. Each one of the text target images is accompanied by a text file (same file name but&nbsp;.txt extension) containing the correct transcription of that particular text target.</p> <p>As a difference to the HDC training data (<a href="https://doi.org/10.5281/zenodo.4916176">https://doi.org/10.5281/zenodo.4916176</a>) the test data character targets include also numbers.&nbsp;&nbsp;</p> <p>A&nbsp;detailed description of the training&nbsp;dataset that was acquired in the exact same way as this test dataset can be found here:&nbsp;<a href="http://arxiv.org/abs/2105.10233">http://arxiv.org/abs/2105.10233</a></p> <p>Here is a link to the&nbsp;official webpage of the Helsinki Deblur Challenge 2021:&nbsp;<a href="https://www.fips.fi/HDC2021.php">https://www.fips.fi/HDC2021.php</a></p>

opencc-by-4.0Nov 2021View details →
zenodo44/100

Resistance, utilization factor curve and polarization curve of test campaign

<p>The datesets refer to the article &quot;Experimental Procedures &amp; First Results of an Innovative Solid Oxide Fuel Cell Test Rig: Parametric Analysis and Stability Test&quot; (https://zenodo.org/badge/DOI/10.5281/zenodo.5763507.svg).</p> <p>Solid Oxide Fuel Cells are a promising technology for Solid Oxide Fuel Cells (SOFC) are a promising technology For high-efficiency electrochemical conversion of a vast range of fuel gas mixtures, thigh operating temperature conditions (650&ndash;900 ◦C) represent a challenge both at system level and at laboratory testing level, in terms of material properties and performance dynamics. In this work a detailed procedural analysis is presented for an innovative all-ceramic compact SOFC test rig and first experimental testing results are reported in terms of polarization curves obtained under parametric variation of operating conditions (H2 content, air ratio &lambda; and temperature) and short-term voltage stability test under load (140 h at 0.3 A/cm2 ). The electrochemical characterization results confirm the validity of the used all-ceramic cell holder, showing excellent cell performances in terms of polarization. H2 content has the most impact on SOFC performance, followed by temperature and finally air ratio, whose impact in the analyzed range is hardly seen. From the short-term stability test, the test bench setup reliability is demonstrated, showing no significant performance degradation after 140 continuous hours under load, which confirms the high quality and reproducibility of the results.</p>

opencc-by-4.0Apr 2021View details →
zenodo44/100

Test Data of Passenger kinematics in Lane change and Lane change with Braking Manoeuvres from Ghaffari et al., 2018

<p>This data was extracted by the &quot;authors&quot; of this dataset from the publication</p> <p><strong>Ghaffari, G., Brolin, K., Br&aring;se, D., Pipkorn, B., Svanberg, B., Jakobsson, L., &amp; Davidsson, J. (2018). Passenger kinematics in Lane change and Lane change with Braking Manoeuvres using two belt configurations: standard and reversible pre-pretensioner. <em>2018 IRCOBI Conference Proceedings, </em>pp. 12-14, <a href="http://www.ircobi.org/wordpress/downloads/irc18/pdf-files/80.pdf">http://www.ircobi.org/wordpress/downloads/irc18/pdf-files/80.pdf</a>.</strong></p> <p>within the OSCCAR project and made publicly available for future validations of active Human Body Models.</p> <p><strong>If you use this data, please cite the original paper.</strong></p> <p>To use the data, a generic model of the vehicle environment is also openly available: <a href="https://openvt.eu/osccar/precrash_seat_models/safer-ahbm_2-3">https://openvt.eu/osccar/precrash_seat_models/safer-ahbm_2-3 </a></p>

opencc-by-4.0Dec 2021View details →
zenodo44/100

Needs of plant health laboratories and applicability of the horizontal proficiency testing approach based on the questionnaire answers

<p>Data collected in the framework of work package 5 of the Valitest project. They correspond to the needs and expectation concerning proficiency assessment expressed by plant health laboratories during a survey conducted online in 2019.</p>

opencc-by-4.0Dec 2021View details →
zenodo44/100

Test and numerical data of a vapour-injection scroll compressor in a heat pump with R1234ze(E)

<p>The dataset contains the experimental results of a water-to-water heat pump tested at the lab for different water temperatures. The refrigerant used is the HFO R1234ze(E). The scroll compressor is equipped with an eco port. The numerical results of a validated semi-empirical model are also included for a standard suction pressure drop model and an improved one.</p>

opencc-by-4.0Dec 2021View details →

ScienceDex guides

Understand access before you commit

These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.

Compare curated datasets

Allen Brain Atlas

Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.

allen-brain-atlas
neuroscienceopenDocumentation, web resources, and API references are available online.
Last verified 2026-04-30Open record

Annotated Behaviour and Observability Dataset (ABODe)

ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.

abode-home-cage
behavioral-neuroscienceopenThe DataShare record exposes download links for annotations, documentation, license text, and the zipped per-snippet data directory.
Last verified 2026-04-30Open record

DANDI Archive for NWB datasets

DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.

dandi-nwb
electrophysiologyopenPublished Dandiset metadata and archive endpoints are available through the production DANDI API.
Last verified 2026-04-30Open record

International Brain Laboratory public data

The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.

ibl
behavioral-neuroscienceopenPublic sessions can be searched and loaded from the IBL public data server through ONE.
Last verified 2026-04-29Open record

OpenNeuro

OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.

openneuro
neuroscienceopenPublished datasets are available on demand over the internet.
Last verified 2026-04-29Open record

ScienceDex for faculty

Your academic CV and NIH biosketch

Make your CV in your school's format and your NIH biosketch from it, then download both as Word files.