Find research datasets worth reusing
Search datasets from major research repositories and use ShareScore to quickly assess how well each record supports discovery, access, and reuse.
33
datasets available to search
ShareScore release 0.9.0
Dataset results
33 results for “Single Pulses”
Single-cycle, 643-mW average power THz source based on tilted pulse front in lithium niobate
<p>This data set is associated with the aforementioned paper.</p> <p>The data and the Jupyter notebooks (Python) to reproduce the figures in this paper can be downloaded below. To run a Jupyter notebook as a beginner, it is easiest to download and install anaconda, a Python environment that comes with many packages preinstalled and also offers Jupyter lab/notebook. It is available at <a href="https://www.anaconda.com/download" target="_blank" rel="noopener">https://www.anaconda.com/download</a>.</p> <h2>Fig.01</h2> <p><strong>Fig.01_literature_lithium_niobate_sources.csv</strong> contains a summary table of the last decades of published THz power values obtained with lithium niobate in the tilted pulse front geometry. The accompanying jupyter notebook allows to reproduce the figure that was used in the paper.</p> <h2>Fig.03</h2> <p>Each individual data frame (df), which is saved as an HDF file in the .zip file, contains a "power curve" measurement (i.e. measured THz power as a function of the applied pump power). Whenever a parameter is changed, all positions, angles, THz power and cryostat parameters are saved.</p> <ul> <li><strong>x1 </strong>is the position of the last mirror before the transmission grating (parallel to the pump beam direction before the crystal) in [mm]</li> <li><strong>x2 </strong>is the position of the first imaging lens in direction of the pump beam propagation direction before the crystal in [mm]</li> <li><strong>x3 </strong>is the position of the second imaging lens in the direction of the pump beam propagation direction before the crystal in [mm]</li> <li><strong>x4 </strong>is the position of the cryostat in the direction of the pump beam before reaching the crystal in [mm]</li> <li><strong>y0 </strong>is the position of the cryostat in the perpendicular direction of the pump beam before reaching the crystal in [mm]</li> <li><strong>α0 </strong>is the angle of the lambda/2 waveplate that allows the pump power to be varied at the crystal in [°]</li> <li><strong>α1 </strong>is the angle of the last mirror before the grating in [°]</li> <li><strong>α2 </strong>is the angle of the transmission grating in [°]</li> <li><strong>thz_power_W </strong>is the obtained power obtained from the Ophir 3A-P-THz power meter in [W]</li> <li><strong>temperature_setpoint_K </strong>is the LakeShore cryostat controller setpoint in [K]</li> <li><strong>temperature_K </strong>is the temperature read from the sensor on the cooling finger (above the crystal) in [K]</li> <li><strong>heater_output </strong>is the amount of power in [%] delivered to the resistive heating element inside the cryostat. 100% corresponds to about 50 W. Its value is controlled by an internal PID loop of the cryostat controller, which tries to stabilize <strong>temperature_K </strong>to <strong>temperature_setpoint_K</strong></li> <li><strong>pump_power </strong>is the average laser power reaching the crystal in [W]. It was calibrated before obtaining the data set by characterizing the lambda/2 waveplate angle <strong>α0</strong> to the value of an NIR power meter just before the cryostat.</li> <li><strong>repetition_rate</strong> is the repetition rate of the laser in [Hz]</li> </ul> <p>As an example, below is one line (for one pump power) of such a data frame:</p> <table> <tbody> <tr> <td> </td> <th>x1</th> <th>x2</th> <th>x3</th> <th>x4</th> <th>y0</th> <th>α0</th> <th>α1</th> <th>α2</th> <th>thz_power_W</th> <th>temperature_setpoint_K</th> <th>temperature_K</th> <th>heater_output</th> <th>pump_power</th> <th>repetition_rate</th> </tr> <tr> <td>0</td> <td>-12.000005</td> <td>2.500039</td> <td>9.100015</td> <td>-5.0</td> <td>-2.0</td> <td>35.905660</td> <td>25.68</td> <td>-23.3</td> <td>0.006000</td> <td>80.0</td> <td>79.883</td> <td>4.4</td> <td>20.0</td> <td>40000.0</td> </tr> </tbody> </table> <p>10 of such power curves were obtained at 100 kHz and 40 kHz and can be found in the respective zip-file.</p> <p> </p> <p><strong>Literature_Power_Efficiency.zip</strong> contains digitzed power and efficiency values from the following references:</p> <ol> <li>X. Wu, D. Kong, S. Hao, et al., "Generation of 13.9-mJ Terahertz Radiation from Lithium Niobate Materials," Advanced Materials 35, 2208947 (2023).</li> <li> <p>P. L. Kramer, M. K. R. Windeler, K. Mecseki, et al., "Enabling high repetition rate nonlinear THz science with a kilowatt-class sub-100 fs laser source," Opt. Express 28, 16951 (2020).</p> </li> <li> <p>T. Kroh, T. Rohwer, D. Zhang, et al., "Parameter sensitivities in tilted-pulse-front based terahertz setups and their implications for high-energy terahertz source design and optimization," Opt. Express, OE 30, 24186–24206 (2022).</p> </li> <li> <p>B. Zhang, Z. Ma, J. Ma, et al., "1.4-mJ High Energy Terahertz Radiation from Lithium Niobates," Laser & Photonics Reviews 15, 2000295 (2021).</p> </li> </ol> <p> </p> <h2>Fig.04</h2> <p><strong>EOS_dfs.p</strong> is a pickle file, contain electro-optic sampling traces, which are already averaged for various pump powers at 40 kHz repetition rate.</p>
Data for Reducing leakage of single-qubit gates for superconducting quantum processors using analytical control pulse envelopes
<p>This dataset contains the experimental data used in the figures of the paper "Reducing leakage of single-qubit gates for superconducting quantum processors using analytical control pulse envelopes" by E. Hyyppä, A. Vepsäläinen, ..., and J. Heinsoo published in PRX Quantum 5, 030353 (2024): https://doi.org/10.1103/PRXQuantum.5.030353.</p> <p>The data is stored mostly as csv-files, the contents of which are explained in the readme-files. Each subfolder corresponds to one figure of the paper and also contains a Jupyter Notebook for plotting the data. The subfolders S1-S10 correspond to the supplementary figures, i.e., figures 6-15 in the Appendix of the paper.</p> <p>Furthermore, we provide a Jupyter notebook in the folder Code_to_plot_FAST_and_HD_DRAG_pulses/ that provides Python functions for evaluating and plotting the proposed FAST DRAG and HD DRAG pulses in time domain and frequency domain. Please cite our paper if you use the Python code for your published research.</p> <p>The notebooks have been tested using the following Python package versions<br>Python 3.11<br>scipy 1.14.1<br>numpy 2.1.0<br>matplotlib 3.9.2</p>
Single-pulse hard x-ray holograms of an exploding water jet
<p>This h5 file contains the holograms of an exploding micro-fluidic jet recorded at the MID setup at EuXFEL. The holograms were recorded with single-pulse illumination of 17.8 keV hard x-rays.</p> <p>The file contains only one group (/frames/pixels) with 4499 frames recorded with the Andor Zyla 5.5 camera used in this experiment.</p> <p>The first 352 frames and frames 4233 to 4499 can be used as empty beam / reference frames. The frames in between are data frames. The microfluidic jet is put in the field of view and is pumped with an IR laser with pumping offset from 5 to -35 ns with respect to the arrival of the XFEL pulse. </p> <p>The data set has been published in:</p> <p>J. Hagemann, M. Vassholz, H. Hoeppe, M. Osterhoff, J. M. Rosselló, R. Mettin, F. Seiboth, A. Schropp, J. Möller, J. Hallmann, C. Kim, M. Scholz, U. Boesenberg, R. Schaffer, A. Zozulya, W. Lu, R. Shayduk, A. Madsen, C. G. Schroer, and T. Salditt, “Single-pulse phase-contrast imaging at free-electron lasers in the hard X-ray regime,” Journal of Synchrotron Radiation 28(1), 52–63 (2021).<br> </p> <p> </p>
Detection of ultra-weak laser pulses by free-running single-photon detectors: modeling dead time and dark counts effects
<p>In quantum communication systems, the precise estimation of the detector´s response to the incoming light is necessary to avoid security breaches. The typical working regime uses a free-running single-photon avalanche diode in combination with attenuated laser pulses at telecom wavelength for encoding information. We demonstrate the validity of an analytical model for this regime which considers the effects of dark counts and dead time on the measured count rate. For the purpose of gaining a better understanding of these effects, the photon detections were separated from the dark counts via a software-induced gating mechanism. The model was verified by experimental data for mean photon numbers covering three orders of magnitude as well as for laser repetition frequencies below and above the inverse dead time. Consequently, our model would be of interest for predicting the detector response not only in the field of quantum communications, but also in any other quantum physics experiment where high detection rates are needed.</p>
High-power intracavity single-cycle THz pulse generation using thin lithium niobate
<p>This dataset is accompanying the paper "High-power intracavity single-cycle THz pulse generation using thin lithium niobate"<br><br><strong>Autocorrelation.txt:</strong> second harmonic generation noncollinear autocorrelation trace data. (measurement device: Femtochrome FR-103XL)</p><p><strong>Spectrum.txt:</strong> optical spectrum (measurement device: APE wavescan)</p><p><strong>RF_1Mspan.txt:</strong> radio frequency spectrum with 1 MHz span (measurement device: ROHDE & SCHWARZ FPC1000)</p><p><strong>RF_1Gspan.txt:</strong> radio frequency spectrum with 1 GHz span (measurement device: ROHDE & SCHWARZ FPC1000)</p><p><strong>EOS_THz_raw.h5: </strong>electro-optic sampling raw data of the THz measurement in HDF-5 format (measurement device: ROHDE & SCHWARZ RTM3004)</p><p><strong>EOS_noise_raw.h5: </strong>electro-optic sampling raw data of the noise measurement in HDF-5 format (measurement device: ROHDE & SCHWARZ RTM3004)</p><p><strong>THz_time.csv:</strong> processed electro-optic sampling data of the THz measurement in time</p><p><strong>THz_freq.csv:</strong> processed electro-optic sampling data of the THz measurement in frequency</p><p><strong>Dark_time.csv:</strong> processed electro-optic sampling data of the noise measurement in time</p><p><strong>Dark_freq.csv:</strong> processed electro-optic sampling data of the noise measurement in frequency</p>
Ancillary Files for Paper: Implementation of the XY interaction family with calibration of a single pulse
<p>These are the supplementary materials for the paper `Implementation of the XY interaction family with calibration of a single pulse`.</p> <p>The analysis and plots from the paper can be recreated from the Jupyter notebook `XY Paper Plotting<br> and Analysis.ipynb`. The notebook depends on the helper functions in the python files<br> `chevron_analysis.py`, `fidelity_analysis.py`, `models.py`, and `utils.py`. The data is stored in<br> JSON and txt files that are in a compressed tarball that can be extracted with the following commands:</p> <p>```bash<br> > tar xjf data.tar.bz2<br> ```</p>
Supplementary material S24: Time course of the loudest Varroa jolting pulse compared to that of a honeybee colony and single bee individual.
<p>Time course of the loudest <em>Varroa </em>jolt on brood-comb with the signal from the full colony and a single bee. The signal seen here in each panel is the integral of the magnitude of acceleration with respect to time. The background vibration that is inherent to the room was calculated and subtracted from this data. The loudest jolt (red) is here compared to the signal of a single bee (black) and the vibrations of the full colony at low and high signal (black). High signal is captured when the frame containing the accelerometer is empty of brood. Low signal is captured when the frame is fully loaded with brood and/or honey. The whooping signal (panel a) was captured during a period of high signal.</p>
Source data for the publication "Single-shot latched readout of a quantum dot qubit using barrier gate pulsing"
<p>This repository contains data and source code for the publication "Single-shot latched readout of a quantum dot qubit using barrier gate pulsing."</p>
A Prospective Single Arm Open Label Study of the FARAPULSE Pulsed Field Ablation System in Subjects With Persistent Atrial Fibrillation
ClinicalTrials.gov study NCT05443594. IPD Sharing: NO. Countries: 4. Publications: 4.
Data from: Fine-scale movement responses of free-ranging harbour porpoises to capture, tagging, and short-term noise pulses from a single airgun
Knowledge about the impact of anthropogenic disturbances on the behavioural responses of cetaceans is constrained by lack of data on fine-scale movements of individuals. We equipped five free-ranging harbour porpoises (Phocoena phocoena) with high-resolution location and dive loggers and exposed them to a single 10 in3 underwater airgun producing high-intensity noise pulses (2−3 second intervals) for one minute. All five porpoises responded to capture and tagging with longer, faster and more directed movements as well as with shorter, shallower, less wiggly dives immediately after release, with natural behaviour resumed in ≤24 hours. When we exposed porpoises to airgun pulses at ranges of 420−690 m with noise level estimates of 135−147 dB re 1µPa2s (SEL), one individual displayed rapid and directed movements away from the exposure site and two individuals used shorter and shallower dives compared to natural behaviour immediately after exposure. Noise-induced movement typically lasted for ≤8 hours with an additional 24-hour recovery period until natural behaviour was resumed. The remaining individuals did not show any quantifiable responses to the noise exposure. Changes in natural behaviour following anthropogenic disturbances may reduce feeding opportunities and evaluating potential population-level consequences should be a priority research area.
Meterwavelength Single-pulse Polarimetric Emission Survey - Supplementary figures and data products
<p>These files contain all the figures in the supplementary material of Meterwavelength Single-pulse Polarimetric Emission Survey by Mitra et al. 2016, ApJ (in press). In addition there are several data products associated with these figures which include the total intensity single pulse as well as average polarization properties of 123 pulsars at two radio frequencies 333 and 618 MHz. The details of each set of files is available in the README file.</p>
Supplementary material S20: Instances of jolting pulses with double-peaks, compared to those with single peaks.
<p>A video to demonstrate a double peak jolt and single peak jolt in quick succession. Video excerpts taken from the brood-comb jolting video (S10) here show instances of a double peak jolt with instances of a single peak jolt. The video and audio are slowed four times both for easier viewing and hearing of the jolting vibration, which is here heard as a ‘knocking’ sound. A double peak jolt can first be seen near to the 29.655 min time stamp on the x axis, immediately followed by a single peak jolt near to the 29.665 min time stamp. The difference in body motion can be best seen when viewing these jolting instances side-by-side. For the double peak, the mite appears to move its body right and then left, whereas for the single peak the body only moves to the right. This is immediately followed by two consecutive instances of single jolts at time stamps 30.3 min and 30.315 min time stamps where the body only moves in a single downward motion. A second instance of a double peak can then be seen at the 31.84 min time stamp, where the mite appears to move the body in a downward motion followed by movement to the right. Two audible ‘knocks’ can be clearly heard for the double peaks, in comparison to the one audible ‘knock’ for the single peaks.</p>
A single center experience of correlation of pulse pressure with mortality of stroke hemorrhage patients in Indonesia
<p>This is an article that describes the relationship between the pulse pressure and mortality of stroke hemorrhagic in Indonesia.</p>
Single Portable Pulse-dose-conserving Device vs. Combined Use of Stationary and Portable.
ClinicalTrials.gov study NCT02079753. IPD Sharing: Not stated. Countries: 1. Publications: 1.
Data from: Fine-scale movement responses of free-ranging harbour porpoises to capture, tagging, and short-term noise pulses from a single airgun
Open the record for dataset details and reuse information.
A Single Arm Pilot Study of Pulsed Field Ablation in the Treatment of Paroxysmal Atrial Fibrillation
ClinicalTrials.gov study NCT04474054. IPD Sharing: NO. Countries: 1. Publications: 0.
Gene expression profile at single cell level of mouse embryonic stem cells (mESCs) cultured in different media pulses
GEO Series GSE268783. Mus musculus. 27 samples. Type: Expression profiling by high throughput sequencing.
Dynamic Nuclear Polarization Pulse Sequence Engineering using Single-Spin Vector Effective Hamiltonians
<p>The repository contains background data for the paper "Dynamic Nuclear Polarization Pulse Sequence Engineering using Single-Spin Vector Effective Hamiltonians". This includeds files for experimental data, and plotting of these (Exp_data folder) and compiled code and input files for evaluation and non-linear optimization of pulse sequences (Non_linear_optimization_compiled_code folder).</p>
PS-BBICS: Pulse Stretching Bulk Built-in Current Sensor for On-chip Measurement of Single Event Transients (raw data from journal article)
<p>This upload contains raw data from the manuscript "PS-BBICS: Pulse Stretching Bulk Built-in Current Sensor for On-chip Measurement of Single Event Transients". The manuscript was published in Microelectronics Reliability, vol. 138, 2022.; DOI: https://doi.org/10.1016/j.microrel.2022.114726</p> <p>The upload consists of .pdf file of the manuscript and .opj files with raw data related to the figures in the manuscript. </p> <p>This work was supported in part by the European Union’s Horizon 2020 research and innovation programme (Grant No. 857558).</p>
A computational study on the energy efficiency of species production by single-pulse streamers in air
<p>This dataset contains the data used to generate the results presented in the article "A computational study on the energy efficiency of species production by single-pulse streamers in air". This dataset includes (1) the source code; (2) the reaction set and transport data file, which contain a list of included reactions, with transport coefficients and their reaction rate coefficients; (3) configuration files for running the simulations and (4) output log files, which contain information about the physics and numerical properties of the simulations.</p>
ScienceDex guides
Understand access before you commit
These curated guides explain access requirements, typical timelines, costs, and reuse considerations for widely used research datasets.
Allen Brain Atlas
Allen Brain Atlas is an Allen Institute collection of brain map atlases, datasets, APIs, and analysis tools covering mouse, human, and non-human primate brain resources.
Annotated Behaviour and Observability Dataset (ABODe)
ABODe is a University of Edinburgh DataShare dataset for behavior classification in group-housed mice using home-cage video, identities, bounding boxes, ground-plate positions, and annotator labels.
DANDI Archive for NWB datasets
DANDI is a BRAIN Initiative archive for publishing and sharing neurophysiology data, including electrophysiology, optophysiology, and behavioral data packaged as NWB and related standards.
International Brain Laboratory public data
The International Brain Laboratory public data releases expose standardized mouse decision-making experiments, including Neuropixels recordings, widefield calcium imaging, behavior, and session metadata accessed through the ONE API.
OpenNeuro
OpenNeuro is a free, open platform for sharing neuroimaging datasets, with public search, dataset pages, and download paths for web, S3, DataLad, and the OpenNeuro CLI.