Gas Cylinder Cabinet
Ventilated storage cabinet for 1-3 compressed gas cylinders with standardized laboratory dimensions and integrated safety features.
| BKSC-2Q | BKSC-3Q |
| Power/Voltage | AC110/220V, 50/60Hz |
| 80L(2 bottles) | 120L(3 bottles) |
| Door Type | Single door |
| External Size(W*D*H) | 600*450*1900mm |
| 900*450*1900mm | 1200*450*1900mm |
The Gas Cylinder Cabinet provides secure storage for compressed gas cylinders in laboratory environments. This ventilated storage cabinet accommodates 1-3 standard gas cylinders (40L-120L total capacity) with single-door access and integrated safety features. The cabinet maintains proper gas cylinder storage conditions while protecting personnel from potential hazards associated with compressed gas handling.
Constructed for laboratory use, the cabinet features standardized dimensions (600-1200mm width configurations) with consistent 1900mm height for integration into existing lab infrastructure. The unit operates on standard AC power (110/220V) and provides appropriate ventilation for safe gas cylinder storage in research facilities.
How It Works
The gas cylinder cabinet operates through passive ventilation and secure containment principles. The cabinet structure provides physical isolation of compressed gas cylinders from laboratory personnel and equipment while maintaining appropriate airflow patterns to prevent gas accumulation. Internal organization features secure cylinder positioning to prevent tipping or rolling during storage.
Ventilation systems integrated into the cabinet design facilitate air exchange to prevent buildup of leaked gases. The single-door design provides controlled access while maintaining containment integrity. The cabinet's standardized dimensions accommodate standard laboratory gas cylinders while fitting within typical laboratory footprints.
Features & Benefits
BKSC-2Q
- BKSC-3Q
Power/Voltage
- AC110/220V, 50/60Hz
80L(2 bottles)
- 120L(3 bottles)
Door Type
- Single door
External Size(W*D*H)
- 600*450*1900mm
900*450*1900mm
- 1200*450*1900mm
Package Size(W*D*H)
- 674*544*2030mm
994*544*2030mm
- 1294*544*2030mm
85kg
- 102kg
105kg
- 124kg
NO.
- NO.1
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Environmental Monitoring
- Industrial Hygiene
- Materials Science
- Microbiology
- Pharmaceutical QC
Capacity
- 40L(1 bottle)
Weight
- 78kg
Weight
- 61.0 kg
Dimensions
- L: 190.0 mm
- W: 60.0 mm
- H: 45.0 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Capacity Range | 40L-120L (1-3 cylinders) with modular configurations | Many storage solutions offer fixed capacity without modular options | Allows laboratories to select appropriate storage capacity without over-purchasing cabinet space |
| Power Compatibility | Dual voltage AC 110/220V, 50/60Hz operation | Single voltage models require specific electrical infrastructure | Provides installation flexibility for international laboratories and diverse electrical systems |
| Construction Weight | 61-102kg net weight depending on configuration | Lighter units may lack structural stability | Robust construction provides stable platform for secure cylinder storage and safety |
| Dimensional Standardization | Consistent 1900mm height across all width configurations | Variable heights complicate laboratory planning | Facilitates integration with existing laboratory infrastructure and space planning |
The Gas Cylinder Cabinet offers modular capacity selection (1-3 cylinders) with standardized laboratory dimensions and dual voltage compatibility. The robust construction (61-102kg range) and consistent height specification (1900mm) facilitate reliable installation across diverse laboratory environments.
Practical Tips
Position cabinet away from ignition sources and ensure adequate clearance around ventilation openings for proper airflow.
Why: Proper positioning maintains safety margins and ensures effective ventilation system operation.
Inspect door seals and ventilation pathways monthly to ensure unobstructed air exchange.
Why: Regular inspection prevents ventilation system degradation that could compromise safety.
Verify cylinder restraint systems are properly engaged before leaving cylinders unattended in the cabinet.
Why: Proper restraint prevents cylinder movement that could cause valve damage or safety hazards.
Organize cylinders by gas type and maintain inventory records of stored contents and pressure levels.
Why: Systematic organization improves laboratory efficiency and supports safety protocols.
If door mechanisms become difficult to operate, check for cylinder interference and verify proper internal organization.
Why: Proper cylinder positioning prevents mechanical interference with cabinet operation.
Clean cabinet interior periodically to remove dust accumulation that could interfere with ventilation systems.
Why: Clean ventilation pathways ensure effective air exchange and prevent contamination buildup.
Setup Guide
What’s in the Box
- Gas cylinder storage cabinet
- Internal cylinder restraint system (typical)
- Ventilation components (typical)
- Door locking mechanism (typical)
- Installation hardware (typical)
- User manual and safety documentation (typical)
- Power cord (typical)
Warranty
ConductScience provides standard manufacturer warranty coverage for materials and workmanship. Technical support is available for installation guidance and operational questions.
Compliance
References
Background reading relevant to this product:
What types of gas cylinders are compatible with this storage cabinet?
The cabinet accommodates standard laboratory gas cylinders with total capacity options of 40L (1 cylinder), 80L (2 cylinders), or 120L (3 cylinders). Consult product datasheet for specific cylinder dimension compatibility and weight limits.
How does the ventilation system prevent gas accumulation?
The cabinet incorporates passive ventilation design to maintain air exchange and prevent buildup of leaked gases. Specific airflow rates and ventilation specifications should be confirmed in the technical documentation.
What electrical requirements are needed for installation?
The cabinet operates on AC 110/220V power supply at 50/60Hz frequency. Installation should follow local electrical codes and laboratory safety requirements for compressed gas storage areas.
How much floor space is required for different cabinet configurations?
External dimensions vary by capacity: 600x450mm footprint for single cylinder (40L), 900x450mm for dual cylinder (80L), and 1200x450mm for triple cylinder (120L) configurations. All units are 1900mm height.
What safety features are integrated into the cabinet design?
The cabinet includes single-door controlled access, integrated ventilation systems, and internal cylinder restraint mechanisms. Specific safety certifications and features should be verified in the product specifications.
How does this cabinet compare to open cylinder storage?
The enclosed cabinet provides controlled ventilation, physical protection, and organized storage compared to open cylinder racks. It offers enhanced safety through containment while maintaining accessibility.
What maintenance is required for proper operation?
Regular inspection of ventilation systems, door mechanisms, and cylinder restraints is recommended. Specific maintenance intervals and procedures should be followed according to manufacturer guidelines.
Can the cabinet be modified for specific laboratory requirements?
The cabinet offers three standard capacity configurations to match different storage needs. Custom modifications should be discussed with the manufacturer to ensure safety and compliance.