Research data · Pathology
Nissl staining in papers
Of 5,185,272 open-access research articles from 2011 to 2025 with a Methods section, 16,697 name a Nissl stain, such as cresyl violet, there.
Papers that name a Nissl stain, year by year
In 2011, 68 of every 10,000 research articles with a Methods section named a Nissl stain (801 papers). By 2025 the count had risen to 1,580, but the share had fallen to 25 of every 10,000.
Open-access papers whose Methods name a Nissl stain, 2011 to 2025
Show the counts for each year
| Year | Papers |
|---|---|
| 2011 | 801 |
| 2012 | 901 |
| 2013 | 949 |
| 2014 | 955 |
| 2015 | 947 |
| 2016 | 936 |
| 2017 | 933 |
| 2018 | 1,081 |
| 2019 | 1,105 |
| 2020 | 1,139 |
| 2021 | 1,430 |
| 2022 | 1,363 |
| 2023 | 1,275 |
| 2024 | 1,302 |
| 2025 | 1,580 |
Frozen or paraffin sections
6,860 papers say how they prepared the sections they stained. 62% cut them frozen and 38% from paraffin. The 30 papers that report both count in each.
Share of papers that cut frozen or from paraffin
Section thickness
8,140 papers give the thickness of the sections they stained. The most reported is 40 µm (18% of them), then 50 µm (15%) and 30 µm (10%).
Each thickness, as a share of the papers that give one
The chart shows the 8 most reported of the 119 thicknesses papers give. A range such as 40 to 50 µm is listed as its own thickness. A paper that reports two thicknesses counts under each, so the shares can add up to more than 100%.
Show all 119 thicknesses as a table
| Thickness | Papers | Share of papers |
|---|---|---|
| 40 µm | 1,477 | 18% |
| 50 µm | 1,217 | 15% |
| 30 µm | 850 | 10% |
| 20 µm | 809 | 10% |
| 5 µm | 761 | 9% |
| 10 µm | 633 | 8% |
| 4 µm | 353 | 4% |
| 60 µm | 323 | 4% |
| 25 µm | 195 | 2% |
| 100 µm | 175 | 2% |
| 8 µm | 150 | 2% |
| 12 µm | 133 | 2% |
| 6 µm | 122 | 1% |
| 7 µm | 114 | 1% |
| 14 µm | 106 | 1% |
| 35 µm | 100 | 1% |
| 80 µm | 92 | 1% |
| 16 µm | 85 | 1% |
| 15 µm | 73 | 1% |
| 3 µm | 48 | 1% |
| 45 µm | 42 | 1% |
| 70 µm | 31 | under 1% |
| 40 to 50 µm | 25 | under 1% |
| 18 µm | 23 | under 1% |
| 75 µm | 21 | under 1% |
| 2 µm | 19 | under 1% |
| 4 to 5 µm | 13 | under 1% |
| 3 to 5 µm | 11 | under 1% |
| 90 µm | 11 | under 1% |
| 4 to 6 µm | 10 | under 1% |
| 8 to 10 µm | 10 | under 1% |
| 1 µm | 9 | under 1% |
| 3 to 4 µm | 9 | under 1% |
| 40 to 60 µm | 9 | under 1% |
| 10 to 15 µm | 8 | under 1% |
| 24 µm | 7 | under 1% |
| 20 to 30 µm | 6 | under 1% |
| 30 to 40 µm | 6 | under 1% |
| 50 to 100 µm | 6 | under 1% |
| 50 to 60 µm | 6 | under 1% |
| 55 µm | 6 | under 1% |
| 9 µm | 6 | under 1% |
| 15 to 20 µm | 5 | under 1% |
| 2.5 µm | 5 | under 1% |
| 25 to 30 µm | 5 | under 1% |
| 30 to 50 µm | 5 | under 1% |
| 32 µm | 5 | under 1% |
| 5 to 7 µm | 5 | under 1% |
| 6 to 8 µm | 5 | under 1% |
| 7 to 8 µm | 5 | under 1% |
| 3.5 µm | 4 | under 1% |
| 35 to 40 µm | 4 | under 1% |
| 6 to 7 µm | 4 | under 1% |
| 60 to 100 µm | 4 | under 1% |
| 60 to 80 µm | 4 | under 1% |
| 2 to 3 µm | 3 | under 1% |
| 26 µm | 3 | under 1% |
| 5 to 10 µm | 3 | under 1% |
| 5 to 6 µm | 3 | under 1% |
| 50 to 80 µm | 3 | under 1% |
| 70 to 80 µm | 3 | under 1% |
| 8 to 12 µm | 3 | under 1% |
| 0.5 µm | 2 | under 1% |
| 10 to 12 µm | 2 | under 1% |
| 10 to 20 µm | 2 | under 1% |
| 12 to 15 µm | 2 | under 1% |
| 12.5 µm | 2 | under 1% |
| 14 to 16 µm | 2 | under 1% |
| 16 to 18 µm | 2 | under 1% |
| 16 to 20 µm | 2 | under 1% |
| 17 µm | 2 | under 1% |
| 20 to 25 µm | 2 | under 1% |
| 23 µm | 2 | under 1% |
| 25 to 35 µm | 2 | under 1% |
| 25 to 50 µm | 2 | under 1% |
| 36 µm | 2 | under 1% |
| 4.5 µm | 2 | under 1% |
| 6 to 10 µm | 2 | under 1% |
| 60 to 70 µm | 2 | under 1% |
| 8 to 15 µm | 2 | under 1% |
| 0.78 µm | 1 | under 1% |
| 1 to 3 µm | 1 | under 1% |
| 1 to 5 µm | 1 | under 1% |
| 1.08 µm | 1 | under 1% |
| 1.35 µm | 1 | under 1% |
| 1.4 µm | 1 | under 1% |
| 10 to 14 µm | 1 | under 1% |
| 10 to 30 µm | 1 | under 1% |
| 10 to 50 µm | 1 | under 1% |
| 11 to 13 µm | 1 | under 1% |
| 12 to 16 µm | 1 | under 1% |
| 12 to 20 µm | 1 | under 1% |
| 15 to 18 µm | 1 | under 1% |
| 18 to 20 µm | 1 | under 1% |
| 19 µm | 1 | under 1% |
| 19.49 µm | 1 | under 1% |
| 2 to 4 µm | 1 | under 1% |
| 2 to 5 µm | 1 | under 1% |
| 2.22 µm | 1 | under 1% |
| 20 to 40 µm | 1 | under 1% |
| 20 to 50 µm | 1 | under 1% |
| 20 to 60 µm | 1 | under 1% |
| 20 to 70 µm | 1 | under 1% |
| 21 µm | 1 | under 1% |
| 22 µm | 1 | under 1% |
| 30 to 80 µm | 1 | under 1% |
| 4 to 8 µm | 1 | under 1% |
| 5 to 8 µm | 1 | under 1% |
| 50 to 75 µm | 1 | under 1% |
| 50.2 µm | 1 | under 1% |
| 50.6 µm | 1 | under 1% |
| 52 µm | 1 | under 1% |
| 64 µm | 1 | under 1% |
| 65 µm | 1 | under 1% |
| 65 to 70 µm | 1 | under 1% |
| 65 to 75 µm | 1 | under 1% |
| 7 to 10 µm | 1 | under 1% |
| 7 to 12 µm | 1 | under 1% |
| 7.5 µm | 1 | under 1% |
Cryostats and microtomes in our store
Cryostats cut frozen sections, which 62% of the papers above report; microtomes cut paraffin sections, which 38% report.
Download the data (CSV)
Each row records one fact about one paper: that it names the stain, how it prepared the stained sections, or their thickness. Every row gives the paper’s PMCID, PMID and year. The file holds no article text.
The free data order adds the file to your ConductScience account.
How we counted
- How we read the papers
- Read from the Methods sections of open-access articles in PubMed Central, courtesy of the U.S. National Library of Medicine. Text-matching rules counted a paper when its Methods name a Nissl stain beside a word such as stain, solution, sections or slides. Cresyl violet and fluorescent Nissl stains count. Papers that name the stain only as a fluorescence standard, or only because a reference atlas's images used it, do not count. The rules took frozen or paraffin from the sentence that names the stain, or from an earlier sentence in its paragraph that says how the sections were cut. Stains on cultured cells count as neither frozen nor paraffin. Thickness came from the same sentences. Sections over 100 µm were left out. A paper that gives the same thickness or preparation more than once counts once.
- How we checked the counts
- We checked this page together with the Oil Red O page. For each of the three counts (naming the stain, how sections were prepared and thickness), we drew 200 random papers, 100 per stain. An AI model, Claude Opus 5.5, compared what we recorded for each paper with its sentences. It did this twice, in November 2026. Each run found 197 of 200 right for naming the stain, 196 for how sections were prepared and 194 for thickness. A paper was right only when its sentences showed the authors applied the stain, said the stained sections were prepared that way or gave that thickness for them. For every count, the two runs marked the same papers wrong.
