Of 5,185,272 open-access research articles from 2011 to 2025 with a Methods section, 24,277 name Oil Red O there.
Papers that name Oil Red O, year by year
In 2011, 38 of every 10,000 research articles with a Methods section named Oil Red O (453 papers). In 2025, 48 of every 10,000 did (3,118 papers).
Open-access papers whose Methods name Oil Red O, 2011 to 2025
Show the counts for each year
| Year | Papers |
|---|---|
| 2011 | 453 |
| 2012 | 589 |
| 2013 | 801 |
| 2014 | 849 |
| 2015 | 996 |
| 2016 | 1,176 |
| 2017 | 1,389 |
| 2018 | 1,372 |
| 2019 | 1,637 |
| 2020 | 2,068 |
| 2021 | 2,344 |
| 2022 | 2,632 |
| 2023 | 2,368 |
| 2024 | 2,485 |
| 2025 | 3,118 |
Frozen or paraffin sections
6,587 papers say how they prepared the sections they stained. 89% cut them frozen and 12% from paraffin. The 49 papers that report both count in each, so the two add up to more than 100%.
Share of papers that cut frozen or from paraffin
Section thickness
4,423 papers give the thickness of the sections they stained. The most reported is 10 µm (31% of them), then 5 µm (20%) and 8 µm (17%).
Each thickness, as a share of the papers that give one
The chart shows the 8 most reported of the 65 thicknesses papers give. A range such as 8 to 10 µm is listed as its own thickness. A paper that reports two thicknesses counts under each, so the shares can add up to more than 100%.
Show all 65 thicknesses as a table
| Thickness | Papers | Share of papers |
|---|---|---|
| 10 µm | 1,358 | 31% |
| 5 µm | 894 | 20% |
| 8 µm | 745 | 17% |
| 7 µm | 358 | 8% |
| 6 µm | 290 | 7% |
| 4 µm | 232 | 5% |
| 12 µm | 86 | 2% |
| 8 to 10 µm | 69 | 2% |
| 20 µm | 61 | 1% |
| 15 µm | 40 | 1% |
| 3 µm | 29 | 1% |
| 9 µm | 23 | 1% |
| 5 to 10 µm | 22 | under 1% |
| 30 µm | 21 | under 1% |
| 6 to 8 µm | 19 | under 1% |
| 14 µm | 17 | under 1% |
| 5 to 7 µm | 15 | under 1% |
| 3 to 4 µm | 13 | under 1% |
| 6 to 10 µm | 12 | under 1% |
| 4 to 5 µm | 11 | under 1% |
| 4 to 6 µm | 11 | under 1% |
| 10 to 15 µm | 10 | under 1% |
| 16 µm | 10 | under 1% |
| 3 to 5 µm | 9 | under 1% |
| 100 µm | 8 | under 1% |
| 2 µm | 7 | under 1% |
| 25 µm | 7 | under 1% |
| 2 to 3 µm | 6 | under 1% |
| 5 to 6 µm | 6 | under 1% |
| 5 to 8 µm | 6 | under 1% |
| 50 µm | 6 | under 1% |
| 10 to 12 µm | 5 | under 1% |
| 18 µm | 4 | under 1% |
| 6 to 7 µm | 4 | under 1% |
| 4 to 8 µm | 3 | under 1% |
| 4.5 µm | 3 | under 1% |
| 40 µm | 3 | under 1% |
| 7 to 10 µm | 3 | under 1% |
| 1 µm | 2 | under 1% |
| 10 to 30 µm | 2 | under 1% |
| 13 µm | 2 | under 1% |
| 4 to 10 µm | 2 | under 1% |
| 7 to 12 µm | 2 | under 1% |
| 7 to 8 µm | 2 | under 1% |
| 80 µm | 2 | under 1% |
| 0.5 µm | 1 | under 1% |
| 0.5 to 10 µm | 1 | under 1% |
| 1 to 2 µm | 1 | under 1% |
| 10 to 16 µm | 1 | under 1% |
| 12 to 15 µm | 1 | under 1% |
| 12 to 20 µm | 1 | under 1% |
| 17 µm | 1 | under 1% |
| 2 to 4 µm | 1 | under 1% |
| 2 to 5 µm | 1 | under 1% |
| 22 µm | 1 | under 1% |
| 3 to 8 µm | 1 | under 1% |
| 3.5 µm | 1 | under 1% |
| 30 to 40 µm | 1 | under 1% |
| 35 µm | 1 | under 1% |
| 4 to 7 µm | 1 | under 1% |
| 6 to 20 µm | 1 | under 1% |
| 60 µm | 1 | under 1% |
| 70 µm | 1 | under 1% |
| 70 to 80 µm | 1 | under 1% |
| 9 to 10 µm | 1 | under 1% |
Cryostats in our store
Cryostats cut frozen sections, which 89% of the papers above report.
Download the data (CSV)
Each row records one fact about one paper: that it names the stain, how it prepared the stained sections, or their thickness. Every row gives the paper’s PMCID, PMID and year. The file holds no article text.
The free data order adds the file to your ConductScience account.
How we counted
- How we read the papers
- Read from the Methods sections of open-access articles in PubMed Central, courtesy of the U.S. National Library of Medicine. Text-matching rules counted a paper when its Methods name Oil Red O beside a word such as stain, solution, sections or slides. The short form ORO counts once the paper has written out the full name. Papers that name the stain only as a fluorescence standard, not as a stain they applied, do not count. The rules took frozen or paraffin from the sentence that names the stain, or from an earlier sentence in its paragraph that says how the sections were cut. Stains on cultured cells count as neither frozen nor paraffin. Thickness came from the same sentences. Sections over 100 µm were left out. A paper that gives the same thickness or preparation more than once counts once.
- How we checked the counts
- We checked this page together with the Nissl stain page. For each of the three counts (naming the stain, how sections were prepared and thickness), we drew 200 random papers, 100 per stain. An AI model, Claude Opus 5.5, compared what we recorded for each paper with its sentences. It did this twice, in November 2026. Each run found 197 of 200 right for naming the stain, 196 for how sections were prepared and 194 for thickness. A paper was right only when its sentences showed the authors applied the stain, said the stained sections were prepared that way or gave that thickness for them. For every count, the two runs marked the same papers wrong.