Ambient Hydrogen Sulfide and Sulfur Dioxide Analyzer
UV fluorescence analyzer with an internal thermal catalytic converter for H₂S and SO₂.

Louise Corscadden, PhD
Director of Science · ConductScience
Ask Louise about Ambient Hydrogen Sulfide and Sulfur Dioxide Analyzer fit, setup, configuration, or quote prep.
Already working with us? Sign in to connect this with My Scientist.
Key Specifications
Full details →- Model fit
- Configured during quote
- SKU family
- CS-AIR-00011
- Sizing
- Model-specific dimensions confirmed from the selected configuration
- Ordering
- Quote-reviewed before fulfillment
- Category
- Air Quality
- Build notes
- Confirm accessories, station layout, and support needs before purchase
An ambient hydrogen sulfide analyzer built on UV fluorescence. An internal thermal catalytic converter turns hydrogen sulfide into sulfur dioxide before the optical bench sees it, so one detector reports both species.
Key features
- Multi-tasking software allows viewing test variables while operating.
- Internal data logging with 1 min to 365 day.
- Temperature and pressure compensation.
- Continuous system diagnosis with alarm.
Applications
Built for odour, wastewater and industrial fenceline monitoring programmes.
- ambient air quality monitoring
Features & Benefits
Range
- 0~500ppb
Lower Detection Limit
- ≤0.5ppb
Zero Drift (24 hours)
- ±1ppb
Response Time
- ≤120s
Indication Error
- ±2%F.S
What does this instrument measure, and who is it for?
It measures ambient hydrogen sulfide and sulfur dioxide. It is built for odour, wastewater and industrial fenceline monitoring programmes. It is designed for continuous, unattended operation in a monitoring shelter or cabinet, with periodic zero and span calibration.
What measurement principle does it use?
Ultraviolet fluorescence, with an internal thermal catalytic converter that turns hydrogen sulfide into sulfur dioxide before the optical bench sees it. One detector therefore reports both species.
Which specifications are confirmed?
The manufacturer's published specification table lists five parameters for this instrument, and every one of them is reproduced on this page. They include Range at 0~500ppb, Lower Detection Limit at ≤0.5ppb and Zero Drift (24 hours) at ±1ppb. ConductScience transcribed them from the manufacturer's engineering documentation without alteration.
What should be confirmed before ordering?
Confirm siting and inlet configuration, zero and span gas supply, the calibration interval your reporting regime requires, and the data acquisition and reporting path. These are configured and quoted per installation, so raise anything unusual about the site during quote review rather than after delivery.
What else is needed to run it?
A zero air generator and a multi-point dilution calibrator. Every concentration this analyser reports is measured against its zero. A zero that is not actually zero is a systematic error in every number downstream of it, so the calibration gear is not an accessory — it is what makes the readings defensible.
How is it supplied?
This instrument is configured and quoted per installation rather than sold at a list price. Request a quote and we will confirm the configuration, the site requirements and the lead time before anything is ordered.
Have a question about this product?
Have a question? Just ask.
Send it over and we'll email you a personalized answer — no call, no scheduling.
Prefer to talk it through?