Automatic Medical Sealer MS100-L
Continuous heat sealing system operating at 10 m/min with 12mm seal width and adjustable margin control for laboratory packaging applications.
| Automation Level | semi-automated |
| Seal Speed | 10m/min |
| Seal Width | 12mm |
| Seal Margin | 0~35mm adjustable |
| Machine Shell Material | Spray carbon steel(standard) or 304 stainless steel(optional) |
| Consumption | 500W |
The Automatic Medical Sealer MS100-L is a continuous heat sealing system designed for packaging applications in laboratory and healthcare environments. Operating at a seal speed of 10 m/min with a 12mm seal width, this unit provides consistent sealing performance for pouches, bags, and flexible packaging materials commonly used in sterile processing workflows.
The sealer features an adjustable seal margin (0-35mm) and LED display for operational monitoring. Available with spray carbon steel construction as standard or optional 304 stainless steel shell material for enhanced chemical resistance. The 500W heating system operates on standard laboratory power supplies (AC110/220V ±10%, 50/60Hz) making it suitable for diverse facility requirements.
How It Works
The MS100-L employs continuous heat sealing technology where flexible packaging materials pass through heated sealing bars that apply controlled temperature and pressure. The heating elements create a localized melt zone in thermoplastic materials, forming a hermetic seal as the material cools while advancing through the sealing mechanism.
The adjustable seal margin system allows positioning of the seal location from 0-35mm from the material edge, accommodating various pouch sizes and sealing requirements. The LED display provides real-time monitoring of operational parameters including temperature, speed, and seal status. The continuous feed mechanism enables high-throughput processing at the specified 10 m/min rate while maintaining consistent seal quality.
Features & Benefits
Automation Level
- semi-automated
Seal Speed
- 10m/min
Seal Width
- 12mm
Seal Margin
- 0~35mm adjustable
Machine Shell Material
- Spray carbon steel(standard) or 304 stainless steel(optional)
Consumption
- 500W
Packing Size(W*D*H)
- 600*380*260mm
Brand
- ConductScience
Research Domain
- Clinical Diagnostics
- Environmental Monitoring
- Food Science
- Materials Science
- Microbiology
- Pharmaceutical QC
Display Type
- LED screen
Power/Voltage
- AC110/220V±10%, 50/60Hz
Weight
- 11/12kg
Weight
- 12.0 kg
Dimensions
- L: 26.0 mm
- W: 60.0 mm
- H: 38.0 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Sealing Speed | 10 m/min continuous operation | Entry-level units often operate at 2-5 m/min | Higher throughput reduces processing time for large batches of laboratory samples |
| Seal Width | 12mm fixed width | Basic models may offer 6-8mm widths | Wider seals provide enhanced integrity for critical laboratory packaging applications |
| Margin Adjustment | 0-35mm adjustable range | Fixed margin positioning is common | Accommodates diverse pouch sizes without tooling changes |
| Construction Options | Standard carbon steel or optional 304 stainless steel | Most units offer single material construction | Stainless steel option enables use in sterile processing environments |
| Display System | LED operational display | Basic models may lack operational feedback | Real-time monitoring enables consistent performance verification |
The MS100-L combines moderate-speed continuous operation with adjustable margin control and optional stainless steel construction. The LED display system and dual material options address laboratory-specific requirements for both performance monitoring and sterile processing compatibility.
Practical Tips
Establish seal parameter settings using test materials before beginning production runs.
Why: Prevents waste of valuable packaging materials and ensures consistent seal quality.
Clean seal bars after each use session to prevent material buildup and maintain seal quality.
Why: Residual material can cause uneven heating and compromise seal integrity.
Allow adequate warm-up time before sealing operations and verify temperature stability.
Why: Temperature variations during startup can result in inconsistent seal quality.
Keep fingers and loose materials away from the sealing area during operation.
Why: Heated seal bars can cause burns and moving parts present pinch point hazards.
Document seal parameters and perform periodic validation testing for critical applications.
Why: Maintains traceability and ensures consistent packaging integrity over time.
Check for proper material threading and margin guide alignment if seals appear irregular.
Why: Misalignment is a common cause of seal defects and material waste.
Setup Guide
What’s in the Box
- MS100-L sealing unit
- Power cord
- Operation manual
- Basic tooling kit (typical)
- Margin adjustment guides (typical)
Warranty
ConductScience provides a one-year manufacturer warranty covering defects in materials and workmanship, with technical support for operational guidance and troubleshooting assistance.
Compliance
What packaging materials are compatible with the MS100-L sealer?
The sealer works with thermoplastic materials including polyethylene, polypropylene, and laminated films commonly used in laboratory packaging. Consult product datasheet for specific material thickness and composition compatibility.
How do I verify seal quality during operation?
Monitor the LED display for consistent operational parameters and perform periodic peel tests or visual inspection of seal appearance. Establish validation protocols based on your specific packaging requirements.
Can the seal width be adjusted for different applications?
The seal width is fixed at 12mm, but the seal margin is adjustable from 0-35mm to accommodate different pouch sizes and sealing positions.
What maintenance is required for consistent performance?
Regular cleaning of seal bars, inspection of heating elements, and verification of margin adjustment mechanisms. Follow the maintenance schedule in the operation manual for optimal performance.
How does the stainless steel option differ from standard construction?
The optional 304 stainless steel shell provides enhanced chemical resistance and easier cleaning for sterile processing environments, while the standard spray carbon steel is suitable for general laboratory use.
What is the warm-up time before the unit is ready for sealing?
Consult the operation manual for specific warm-up times, which vary based on ambient temperature and desired sealing temperature settings.