Automatic Purge and Trap Device
Fully automated purge and trap device for VOC analysis in water, soil, and food samples with 72-position autosampler and precise temperature control. Meets HJ639-2012, HJ686-2014, and HJ605-2011 regulatory standards for environmental and food safe...
| Temperature Control Range of Water Trap | RT~240 ℃, with an increment of 1°C, the heating power is about 100W; |
| Temperature Control Range of Valve Injection Syste | RT~220 ℃, with an increment of 1°C, the heating power is about 150W; |
| Cold Trap Temperature | The lowest cooling temperature can reach - 30 ℃, and electronic refrigeration device is used; |
| Sample Temperature Control Range | RT~90 ℃, with an increment of 1°C, the heating power is about 250W; |
| Hot Water Pool Temperature Control Range | RT~90 ℃, with an increment of 1°C, the heating power is about 220W; |
| Purge Pipe Temperature Control Range: | RT~90 ℃, with an increment of 1°C, the heating power is about 50W; |
Overview
The Automatic Purge and Trap Device is a fully automated analytical instrument designed for volatile organic compound (VOC) analysis in water, soil, and food samples. This system meets multiple regulatory standards including HJ639-2012, HJ686-2014, and HJ605-2011 for VOC determination using purge and trap/gas chromatography-mass spectrometry methods. The device features precise temperature control across multiple zones and automated sample handling capabilities for high-throughput analysis.
Key Features
The system incorporates multiple temperature-controlled zones with ±0.1°C accuracy, including a desorption temperature range up to 400°C with rapid heating rates exceeding 2000°C/min. The electronic refrigeration system achieves cold trap temperatures as low as -30°C. With 72 sample positions accommodating 40ml bottles, the device enables unattended operation for large sample batches. Continuously adjustable purging flow (0-500ml/min) and back blowing flow (0-200ml/min) provide optimal extraction conditions for various sample types.
Applications
This instrument is essential for environmental laboratories conducting water quality monitoring, soil contamination assessment, and food safety testing. It supports regulatory compliance testing for drinking water, groundwater, surface water, soil, sediment, and food matrices. The automated operation makes it ideal for routine analysis in commercial laboratories, environmental consulting firms, and regulatory agencies requiring reliable VOC quantification with minimal operator intervention.
Temperature Control Range of Water Trap
- RT~240 ℃, with an increment of 1°C, the heating power is about 100W;
Temperature Control Range of Valve Injection Syste
- RT~220 ℃, with an increment of 1°C, the heating power is about 150W;
Cold Trap Temperature
- The lowest cooling temperature can reach - 30 ℃, and electronic refrigeration device is used;
Sample Temperature Control Range
- RT~90 ℃, with an increment of 1°C, the heating power is about 250W;
Hot Water Pool Temperature Control Range
- RT~90 ℃, with an increment of 1°C, the heating power is about 220W;
Purge Pipe Temperature Control Range:
- RT~90 ℃, with an increment of 1°C, the heating power is about 50W;
Sample Bottle Specification
- 40ml
Purging Flow
- 0~500ml / min (continuously adjustable);
Back blowing flow
- 0 ~ 200ml / min (continuously adjustable)
Package Size(W*D*H)
- 1005*635*725mm
Brand
- ConductScience
Weight
- 40kg
Weight
- 40.0 kg
Dimensions
- L: 72.5 mm
- W: 100.5 mm
- H: 63.5 mm