ConductVision GMP

Contact between hands, items and surfaces

Many practices forbid a touch: a component bag on the hopper, a gloved hand on a door, a hand on vials at capping. ConductVision detects the contact your procedures name and flags it for a trained reviewer to decide.

Illustrative detection overlay: A component bag touching the hopperA drawn top-down view of a filling room. Dashed boxes mark the component hopper and a component bag held by an operator labelled Subject 2. An amber mark shows the point where the bag touches the hopper rim.RABSHopperDoorDrawn for CAM-03 Component hopperILLUSTRATIONBagBag touching the hopperSubject 2
Illustrative detection overlayThe detector finds the bag and the hopper in each frame. The amber mark is where the bag touched the hopper rim, which opens a case for a reviewer. Drawn from the demo's sample data; no real site or footage.

What the camera sees

What the camera has to see

A contact check needs to find both things in each frame, such as the component bag and the hopper, or a gloved hand and a door, and to see the moment they meet. A close view helps. In the demo, one camera looks straight at the component hoppers and the infeed.

Some checks also look at how an item is handled. Component loading asks whether each component sits in its nest, whether the trays are level and whether anything touches a product-contact surface.

The camera never needs to know who someone is. Each person gets a label, such as Subject 2, that holds within one camera and one shift.

From rule to check

How a rule becomes a check

Each contact check starts from a written rule, such as: component bags do not touch the component hopper while it is loaded. The rule names what must not touch, the camera views that see it and when the rule applies.

When the detector sees the contact, the monitoring computer opens a case with the camera, the rule and its version, the detector and its version, the operator label and a short clip.

Practices outside the demo, such as a door opened with gloved hands or goggles touched after gowning, are added at setup with their own rule, cameras and detector.

Running examples

Running in the demo

Sample data from the ConductCompliance demo. Every name, rule and version is an example.

  • Trained detectorSample data

    C2 Components loaded incorrectly at the infeed

    Camera view
    CAM-02 RABS front, CAM-03 Component hopper
    Example rule R-02 v1.0
    Containers and closures are loaded as the line setup procedure shows: each component seated in its nest, trays level, and no touch on product-contact surfaces.
    Detector
    loading 0.2.0
  • Trained detectorSample data

    C5 Component bag touching the hopper

    Camera view
    CAM-03 Component hopper
    Example rule R-05 v1.0
    Component bags do not touch the component hopper while it is loaded.
    Detector
    bag-contact 0.2.0

Practices

The practices it serves

Practices outside the demo are added at setup with their own rule, cameras, limit and detector. The rule, the regulations and the record for each practice are on ConductCompliance: aseptic interventions, gowning practices, personnel flow in aseptic areas and aseptic technique.

In ConductCompliance

What it produces in ConductCompliance

A detection flags a possible departure from a written rule. A trained reviewer decides each case in ConductCompliance, and those decisions become the records your quality unit signs.

  • ConductVision

    A detection against a rule

    ConductCompliance

    A case with a unique ID, the detection time from the site clock, camera, area, shift, condition, rule and rule version, and detector version

    Where it shows
    Review queue; event record PDF
    Traced to
    URS-01; OQ-01

    See it on ConductCompliance: how a reviewer decides each case

  • ConductVision

    The evidence clip and frames

    ConductCompliance

    Named on the case; they stay on the site network

    Where it shows
    Case; event record
    Traced to
    URS-02; IQ-05

    See it on ConductCompliance: the reports and event records

  • ConductVision

    The operator label (for example Subject 8)

    ConductCompliance

    On the case and operator reports, never linked to a name

    Where it shows
    Case; operator reports
    Traced to
    URS-28

    See it on ConductCompliance: how operators stay anonymous

Across industries

The general capability

These pages cover GMP areas. For the general capability across industries, see Behavioral Analytics.

Questions

Common questions

Does every touch open a case?

Only contact the rule names, in the views it names. A trained reviewer then decides each case: confirm it, dismiss it with a reason or escalate it to a quality lead.

What if something blocks the view?

The reviewer can dismiss the case with a reason, such as the camera view not showing enough. Dismissals stay in the audit trail and the reports, so the counts still add up.

Is the operator named?

No. The case shows a label such as Subject 2, and ConductCompliance keeps no link from a label to a name.

Plan a GMP monitoring pilot