ConductVision GMP
Detection methods
Every GMP practice a camera checks comes down to what the camera has to see. Six methods cover them, from measurements against your limits to steps followed in the order your procedures set.
Three kinds of detector
ConductVision runs three kinds of detector today. A measurement follows each person and compares a number, such as walking pace, with the limit in your procedure. A trained detector recognizes one action, such as an arm passing over open containers or a component bag touching the hopper. A sequence check follows steps and their order, such as glove disinfection between glove ports or the gowning steps.
Each detector has a name and a version, and every case records both, with the rule and the rule version it was checked against.
Six methods, grouped by what the camera sees
Measurements, zones, contact and sequences cover the six practices that run in the demo. People counts and flow, and attire and objects, cover practices from the condition library and the requirements a camera can check. None of those runs in the demo yet.
One method can serve many practices. Contact covers a component bag touching the hopper and a gloved hand on a door alike, and each practice keeps its own rule, cameras, limit and detector.
From method to record
Whatever the method, a detection opens a case in ConductCompliance, and a trained reviewer on your team decides it. The rule, the regulations behind it and the record for each practice are on the ConductCompliance practice pages.
Detection methods
The six detection methods
Measurements
Walking pace and time at a station, measured against the limits in your procedures.
- Moving too fast in the filling room
- Inspector breaks and time at the station during visual inspection
Zones
Reaching over open containers, interventions and movement next to the critical area.
- Reaching over open containers
- Grade A intervention not on the approved list, or not recorded
- How much operators move next to the critical area
Contact
Contact your procedures forbid, from bags on the hopper to gloved hands on doors.
- Components loaded incorrectly at the infeed
- Component bag touching the hopper
- Jam cleared without sterile tools
- Goggles or face touched after gowning
- Leaning on equipment
- Door opened with gloved hands
- Hands touching vials at the capping station
Sequences
Gowning steps and glove disinfection, followed in the order your procedure sets.
- Gloves not disinfected before sterile handling or between glove ports
- Gowning step missed or out of order
- Gloves changed or sanitized just before glove sampling
- A garment inspected before and after gowning
- Items inspected on removal from the autoclave
People counts and flow
People in a room, entries and exits, and the direction people move through change rooms.
- More people in the gowning room than its limit
- Two people through one door opening
- How often people enter and leave the aseptic processing room and its critical area
- People leaving grade B through the change room meant for entry
Attire and objects
What people wear and carry, and where components and doors should be.
- Skin exposed after gowning
- Component boxes or bags stored on the floor, or without spacing
- Both airlock doors open at the same time
- Grade A and B gowning worn while working in a grade C area
- A watch, jewelry or a phone in the cleanroom
In ConductCompliance
What it produces in ConductCompliance
A detection flags a possible departure from a written rule. A trained reviewer decides each case in ConductCompliance, and those decisions become the records your quality unit signs.
ConductVision
A detection against a rule
ConductCompliance
A case with a unique ID, the detection time from the site clock, camera, area, shift, condition, rule and rule version, and detector version
- Where it shows
- Review queue; event record PDF
- Traced to
- URS-01; OQ-01
See it on ConductCompliance: how a reviewer decides each case
ConductVision
A measurement against a limit (for example walking pace)
ConductCompliance
The measured value and its limit
- Where it shows
- Event record PDF
- Traced to
- Shown on the event record
See it on ConductCompliance: the reports and event records
ConductVision
The detector name and version
ConductCompliance
On every case; each release with notes, affected functions and validation impact
- Where it shows
- Case; change control record
- Traced to
- URS-26, URS-27; OQ-19
See it on ConductCompliance: the validation package contents
Questions
Common questions
Which method does a practice use?
The one that matches what the camera has to see. Walking pace is a measurement, reaching over open containers uses a zone drawn above them, and gowning order is a sequence. Each method page lists the practices it serves.
Can one camera serve several methods?
Yes. In the demo, the RABS front view serves component loading, reaching over open containers and glove disinfection, and each practice keeps its own rule and detector.
Who decides whether a detection is a deviation?
A trained reviewer on your team decides each case, and your deviation procedure decides what happens after that. A detection only flags a possible departure from a rule.
Plan a GMP monitoring pilot
Start with one practice, your own cameras and procedures, and a results review with your team at the end.
