ConductVision GMP
Steps in the right order
Gowning, glove disinfection and garment checks are steps that must happen, in the order your procedures set. ConductVision follows the steps on camera and flags a missed or out-of-order step for a trained reviewer to decide.
What the camera sees
What the camera has to see
A sequence check follows one person through a set of steps and notes each step as it happens. In a gowning room, that means each item going on in turn. At the RABS, it means glove disinfection between uses of the glove ports and before sterile handling.
The camera needs a view of every step. In the demo, a wide view of the step-over bench and the mirror covers gowning, and a close view at the front of the RABS covers the glove ports.
Each person gets a label, such as Subject 5, that holds within one camera and one shift, so the steps stay tied to one person without anyone being named.
From rule to check
How a rule becomes a check
Each sequence check starts from a written rule, such as: each gowning step is done, in the order the gowning procedure sets. The rule lists the steps, their order, and where the sequence starts and ends.
When a step is missed or comes out of order, the monitoring computer opens a case with the rule and its version, the detector and its version, the operator label and a short clip. The case says what was seen, such as no hand sanitizing before sterile gloves.
Your procedure sets the steps. When it changes, the rule gets a new version, and each case records the version it was checked against.
Running examples
Running in the demo
Sample data from the ConductCompliance demo. Every name, rule and version is an example.
- Sequence checkSample data
C4 Gloves not disinfected before sterile handling or between glove ports
- Camera view
- CAM-02 RABS front
- Example rule
R-04 v1.0 - Gloves are disinfected before handling sterile supplies and between uses of the RABS gauntlet gloves.
- Detector
glove-sequence 0.3.0
- Sequence checkSample data
C6 Gowning step missed or out of order
- Camera view
- CAM-04 Gowning room
- Example rule
R-06 v1.0 - Each gowning step is done, in the order the gowning procedure sets.
- Detector
gowning-sequence 0.5.0
Practices
The practices it serves
- Gloves not disinfected before sterile handling or between glove portsRunning in the demo (C4)
- Gowning step missed or out of orderRunning in the demo (C6)
- Gloves changed or sanitized just before glove samplingIn the condition library
- A garment inspected before and after gowningA requirement a camera can check
- Items inspected on removal from the autoclaveA requirement a camera can check
- No glove change when moving between filling linesIn the condition library
- No glove change after touching the floorIn the condition library
- No glove change after surface disinfectionIn the condition library
- No glove change before unloading the autoclaveIn the condition library
- Hands not sanitized before gloving, or gloves donned out of orderIn the condition library
- Gloves not disinfected before a grade A interventionIn the condition library
- Surface disinfection technique not followedIn the condition library
Practices outside the demo are added at setup with their own rule, cameras, limit and detector. The rule, the regulations and the record for each practice are on ConductCompliance: glove practices, gowning practices and handling materials and components.
In ConductCompliance
What it produces in ConductCompliance
A detection flags a possible departure from a written rule. A trained reviewer decides each case in ConductCompliance, and those decisions become the records your quality unit signs.
ConductVision
A detection against a rule
ConductCompliance
A case with a unique ID, the detection time from the site clock, camera, area, shift, condition, rule and rule version, and detector version
- Where it shows
- Review queue; event record PDF
- Traced to
- URS-01; OQ-01
See it on ConductCompliance: how a reviewer decides each case
ConductVision
The detector name and version
ConductCompliance
On every case; each release with notes, affected functions and validation impact
- Where it shows
- Case; change control record
- Traced to
- URS-26, URS-27; OQ-19
See it on ConductCompliance: the validation package contents
ConductVision
The operator label (for example Subject 8)
ConductCompliance
On the case and operator reports, never linked to a name
- Where it shows
- Case; operator reports
- Traced to
- URS-28
See it on ConductCompliance: how operators stay anonymous
Across industries
The general capability
These pages cover GMP areas. For the general capability across industries, see Behavioral Analytics.
Questions
Common questions
What if our gowning procedure differs from the demo?
The demo's steps are sample data. At setup, the rule is written from your own gowning procedure, and your site approves it.
Does a missed step mean a deviation?
No. It opens a case. A trained reviewer watches the clip and confirms it, dismisses it with a reason or escalates it to a quality lead. Your deviation procedure decides what happens after that.
Can it check glove changes too?
Glove changes, such as after touching the floor or when moving between filling lines, are in the condition library. Each is added at setup with its own rule, cameras and detector.
Plan a GMP monitoring pilot
Start with one practice, your own cameras and procedures, and a results review with your team at the end.
