ConductVision GMP

Steps in the right order

Gowning, glove disinfection and garment checks are steps that must happen, in the order your procedures set. ConductVision follows the steps on camera and flags a missed or out-of-order step for a trained reviewer to decide.

Illustrative detection overlay: Glove disinfection between glove portsA drawn top-down view of a filling room. An operator labelled Subject 7 moves from glove port 3 to glove port 4. Below, three steps in order: glove port 3, disinfect gloves, glove port 4. The middle step is marked as not seen.RABSHopperDoorDrawn for CAM-02 RABS frontILLUSTRATION1234Subject 7Glove port 3Disinfect glovesGlove port 4Not seen between the two glove ports
Illustrative detection overlayA sequence check follows the steps the rule sets, in order. Here the operator moved from glove port 3 to port 4 with no glove disinfection seen between them, which opens a case for a reviewer. Drawn from the demo's sample data; no real site or footage.

What the camera sees

What the camera has to see

A sequence check follows one person through a set of steps and notes each step as it happens. In a gowning room, that means each item going on in turn. At the RABS, it means glove disinfection between uses of the glove ports and before sterile handling.

The camera needs a view of every step. In the demo, a wide view of the step-over bench and the mirror covers gowning, and a close view at the front of the RABS covers the glove ports.

Each person gets a label, such as Subject 5, that holds within one camera and one shift, so the steps stay tied to one person without anyone being named.

From rule to check

How a rule becomes a check

Each sequence check starts from a written rule, such as: each gowning step is done, in the order the gowning procedure sets. The rule lists the steps, their order, and where the sequence starts and ends.

When a step is missed or comes out of order, the monitoring computer opens a case with the rule and its version, the detector and its version, the operator label and a short clip. The case says what was seen, such as no hand sanitizing before sterile gloves.

Your procedure sets the steps. When it changes, the rule gets a new version, and each case records the version it was checked against.

Running examples

Running in the demo

Sample data from the ConductCompliance demo. Every name, rule and version is an example.

  • Sequence checkSample data

    C4 Gloves not disinfected before sterile handling or between glove ports

    Camera view
    CAM-02 RABS front
    Example rule R-04 v1.0
    Gloves are disinfected before handling sterile supplies and between uses of the RABS gauntlet gloves.
    Detector
    glove-sequence 0.3.0
  • Sequence checkSample data

    C6 Gowning step missed or out of order

    Camera view
    CAM-04 Gowning room
    Example rule R-06 v1.0
    Each gowning step is done, in the order the gowning procedure sets.
    Detector
    gowning-sequence 0.5.0

Practices

The practices it serves

Practices outside the demo are added at setup with their own rule, cameras, limit and detector. The rule, the regulations and the record for each practice are on ConductCompliance: glove practices, gowning practices and handling materials and components.

In ConductCompliance

What it produces in ConductCompliance

A detection flags a possible departure from a written rule. A trained reviewer decides each case in ConductCompliance, and those decisions become the records your quality unit signs.

  • ConductVision

    A detection against a rule

    ConductCompliance

    A case with a unique ID, the detection time from the site clock, camera, area, shift, condition, rule and rule version, and detector version

    Where it shows
    Review queue; event record PDF
    Traced to
    URS-01; OQ-01

    See it on ConductCompliance: how a reviewer decides each case

  • ConductVision

    The detector name and version

    ConductCompliance

    On every case; each release with notes, affected functions and validation impact

    Where it shows
    Case; change control record
    Traced to
    URS-26, URS-27; OQ-19

    See it on ConductCompliance: the validation package contents

  • ConductVision

    The operator label (for example Subject 8)

    ConductCompliance

    On the case and operator reports, never linked to a name

    Where it shows
    Case; operator reports
    Traced to
    URS-28

    See it on ConductCompliance: how operators stay anonymous

Across industries

The general capability

These pages cover GMP areas. For the general capability across industries, see Behavioral Analytics.

Questions

Common questions

What if our gowning procedure differs from the demo?

The demo's steps are sample data. At setup, the rule is written from your own gowning procedure, and your site approves it.

Does a missed step mean a deviation?

No. It opens a case. A trained reviewer watches the clip and confirms it, dismisses it with a reason or escalates it to a quality lead. Your deviation procedure decides what happens after that.

Can it check glove changes too?

Glove changes, such as after touching the floor or when moving between filling lines, are in the condition library. Each is added at setup with its own rule, cameras and detector.

Plan a GMP monitoring pilot

Start with one practice, your own cameras and procedures, and a results review with your team at the end.