ConductVision GMP

Measurements against your limits

Some practices come down to a number in your procedure, such as how fast people may walk near open product. ConductVision measures it on camera and flags a measurement over your limit for a trained reviewer to decide.

Illustrative detection overlay: Walking pace in the filling roomA drawn top-down view of a filling room with the RABS, its glove ports, open containers on the line, the component hopper and the door. A tracked person, labelled Subject 4, walks in from the door and along the front of the RABS. One stretch of the track, where the dots spread apart, is marked as pace over the limit.RABSHopperDoorCAM-01 Filling room overviewILLUSTRATIONPace over the limitSubject 4
Illustrative detection overlayEach dot is one tracked position, taken at a fixed interval, so wider spacing means faster walking. The amber stretch is where the measured pace passed the rule's limit, which opens a case for a reviewer. Drawn from the demo's sample data; no real site or footage.

What the camera sees

What the camera has to see

A measurement needs two things from the camera. It has to follow each person from frame to frame, and it has to know real distances on the floor. At setup, each camera view is calibrated to the floor, so movement in the picture becomes meters walked in the room.

Time and counts work without floor distances. For time at a station, such as an inspector at a visual inspection booth, the camera notes when a person arrives and when they leave. For a count, such as wipe strokes across a surface, the measurement is the number of strokes.

The camera never needs to know who someone is. Each person gets a label, such as Subject 4, that holds within one camera and one shift.

From rule to check

How a rule becomes a check

Each measurement starts from a written rule in your procedure. The rule names the area and the camera views, what is measured, the limit, and the stretch of time a measurement covers.

The detector compares each measurement with the limit. When a measurement passes the limit, the monitoring computer opens a case with the measured value, the limit, the rule and its version, the detector and its version, and a short clip.

Your site sets every limit and approves every rule. Rules carry a version, and each case records the rule version it was checked against.

Running examples

Running in the demo

Sample data from the ConductCompliance demo. Every name, rule and version is an example.

  • MeasurementSample data

    C1 Moving too fast in the filling room

    Camera view
    CAM-01 Filling room overview
    Example rule R-01 v1.0
    Operators in the filling room walk at or below 0.5 m/s, measured over any 2-second stretch.
    Detector
    pace 0.4.0

Practices

The practices it serves

Practices outside the demo are added at setup with their own rule, cameras, limit and detector. The rule, the regulations and the record for each practice are on ConductCompliance: cleanroom conduct.

In ConductCompliance

What it produces in ConductCompliance

A detection flags a possible departure from a written rule. A trained reviewer decides each case in ConductCompliance, and those decisions become the records your quality unit signs.

  • ConductVision

    A detection against a rule

    ConductCompliance

    A case with a unique ID, the detection time from the site clock, camera, area, shift, condition, rule and rule version, and detector version

    Where it shows
    Review queue; event record PDF
    Traced to
    URS-01; OQ-01

    See it on ConductCompliance: how a reviewer decides each case

  • ConductVision

    A measurement against a limit (for example walking pace)

    ConductCompliance

    The measured value and its limit

    Where it shows
    Event record PDF
    Traced to
    Shown on the event record

    See it on ConductCompliance: the reports and event records

  • ConductVision

    The detector name and version

    ConductCompliance

    On every case; each release with notes, affected functions and validation impact

    Where it shows
    Case; change control record
    Traced to
    URS-26, URS-27; OQ-19

    See it on ConductCompliance: the validation package contents

  • ConductVision

    The site clock

    ConductCompliance

    Every event and decision time, in site time with the time zone

    Where it shows
    All records
    Traced to
    URS-23; IQ-03

    See it on ConductCompliance: the audit trail

Across industries

The general capability

These pages cover GMP areas. For the general capability across industries, see Behavioral Analytics.

Questions

Common questions

Does a measurement over the limit mean a deviation?

No. It opens a case. A trained reviewer watches the clip and confirms it, dismisses it with a reason or escalates it to a quality lead. Your deviation procedure decides what happens after that.

Who sets the limit?

Your site does, in its procedure. The limits in the demo are sample data that show how the system works. They are not recommendations.

How accurate are the measurements?

We publish no accuracy figures yet. Measurements are checked on your own recorded clips during a pilot, and any figure we publish names the conditions it was measured under.

Is anyone named in the record?

No. The case shows a label such as Subject 4, and ConductCompliance keeps no link from a label to a name.

Plan a GMP monitoring pilot

Start with one practice, your own cameras and procedures, and a results review with your team at the end.