Research data · Settings in papers
Tail flick test settings
Our text-matching rules read the Methods of 1,871 open-access papers from 2011 to 2025 that name the tail flick test, in either version: a heat beam on the tail, or a dip in hot water.
What cut-off do tail flick papers set?
Most often 10 s: 45% of the 951 papers whose Methods give a cut-off set it; 22% set 15 s. 10 s leads in both: 51% of the 610 mouse papers and 35% of the 337 rat papers that give one.
The tail flick test page also answers How is a nociceptive threshold calculated from tail flick latencies?
Papers by the cut-off time they give
In the 406 papers that also give a water temperature, 10 s leads at 42% and 15 s follows at 30%. In the 545 that give no water temperature (beam papers, and any hot-water papers that left it out), 10 s leads at 47%, and 15 s follows at 16%. A baseline limit used to leave animals out, and a cap on total time across trials, are not counted as cut-offs. In the chart, a paper that names two cut-offs counts under each, so the shares add to more than 100%. The chart leaves out the 6 cut-offs given as a range.
Show all cut-off times
| Cut-off time | Mouse papers | Rat papers | One value, both species | All papers |
|---|---|---|---|---|
| 4 s | 1 | 0 | 0 | 1 |
| 5 s | 0 | 1 | 0 | 1 |
| 6 s | 8 | 5 | 0 | 13 |
| 7 s | 2 | 1 | 0 | 3 |
| 8 s | 13 | 11 | 1 | 25 |
| 9 s | 8 | 3 | 0 | 11 |
| 10 s | 310 | 118 | 2 | 430 |
| 10.2 s | 0 | 1 | 0 | 1 |
| 12 s | 20 | 28 | 0 | 48 |
| 13 s | 1 | 1 | 0 | 2 |
| 14 s | 0 | 2 | 0 | 2 |
| 14.9 s | 0 | 1 | 0 | 1 |
| 15 s | 131 | 77 | 1 | 209 |
| 16 s | 7 | 5 | 0 | 12 |
| 17 s | 0 | 1 | 0 | 1 |
| 20 s | 64 | 40 | 1 | 105 |
| 21 s | 0 | 1 | 0 | 1 |
| 22 s | 4 | 1 | 0 | 5 |
| 24 s | 0 | 1 | 0 | 1 |
| 25 s | 11 | 5 | 0 | 16 |
| 30 s | 32 | 24 | 0 | 56 |
| 40 s | 6 | 4 | 0 | 10 |
| 50 s | 0 | 3 | 0 | 3 |
| 60 s | 5 | 2 | 0 | 7 |
| 10 to 12 s | 0 | 3 | 0 | 3 |
| 10 to 15 s | 1 | 0 | 0 | 1 |
| 15 to 30 s | 1 | 0 | 0 | 1 |
| 45 to 60 s | 1 | 0 | 0 | 1 |
920 of the 1,871 papers give no cut-off.
What water temperature do tail flick papers give?
606 of the 1,871 papers (32%) give a water temperature, so they ran the hot-water version. The others give none, so their version can't be told. Most often 52°C for the hot-water version: 28% of the 606 papers whose Methods give a water temperature name it; 23% name 50°C and 21% 55°C. 52°C leads in both mouse and rat papers, and 50°C and 55°C follow in both.
Papers by the water temperature they give
In the chart, a paper that names two temperatures counts under each, so the shares add to more than 100%. A tail dipped in cold water is not counted. The chart leaves out the 15 temperatures given as a range.
Show all water temperatures
| Water temperature | Mouse papers | Rat papers | One value, both species | All papers |
|---|---|---|---|---|
| 44°C | 0 | 1 | 0 | 1 |
| 45°C | 5 | 2 | 0 | 7 |
| 46°C | 12 | 3 | 0 | 15 |
| 46.5°C | 2 | 0 | 0 | 2 |
| 47°C | 8 | 1 | 0 | 9 |
| 47.5°C | 1 | 0 | 0 | 1 |
| 48°C | 58 | 8 | 1 | 67 |
| 49°C | 21 | 7 | 0 | 28 |
| 50°C | 102 | 37 | 1 | 140 |
| 50.2°C | 1 | 0 | 0 | 1 |
| 51°C | 6 | 1 | 0 | 7 |
| 52°C | 127 | 42 | 0 | 169 |
| 52.5°C | 20 | 6 | 0 | 26 |
| 53°C | 4 | 1 | 0 | 5 |
| 54°C | 18 | 5 | 1 | 24 |
| 55°C | 98 | 30 | 0 | 128 |
| 55.5°C | 1 | 0 | 0 | 1 |
| 56°C | 30 | 2 | 0 | 32 |
| 58°C | 0 | 1 | 0 | 1 |
| 60°C | 0 | 1 | 0 | 1 |
| 46 to 52°C | 0 | 1 | 0 | 1 |
| 48 to 52.5°C | 1 | 0 | 0 | 1 |
| 48 to 56°C | 1 | 0 | 0 | 1 |
| 49 to 51°C | 1 | 0 | 0 | 1 |
| 50 to 52°C | 1 | 1 | 0 | 2 |
| 50 to 55°C | 1 | 2 | 0 | 3 |
| 52 to 56°C | 1 | 0 | 0 | 1 |
| 53 to 54°C | 3 | 0 | 0 | 3 |
| 55 to 55.5°C | 1 | 0 | 0 | 1 |
| 55 to 56°C | 0 | 1 | 0 | 1 |
1,265 of the 1,871 papers give no water temperature.
Do tail flick papers give the beam intensity?
Rarely: 60 of the 1,871 papers give one; 606 of the 1,871 are hot-water papers. They give it on three scales: a percent of full power (22 papers), a number on the device's own dial (31) and watts (7). We show a scale's values once at least 30 papers give it, so this page shows the dial numbers and leaves the percents and watts to the download. The download holds the values of all 60.
The tail flick test page also answers What equipment measures tail flick latency?
Papers by the dial number they give
A dial number means something only on the device it was set on, so dial numbers from different devices can't be compared.
Show all dial numbers
| Dial number | Mouse papers | Rat papers | One value, both species | All papers |
|---|---|---|---|---|
| 4 | 0 | 1 | 0 | 1 |
| 5 | 6 | 2 | 0 | 8 |
| 5.5 | 0 | 1 | 0 | 1 |
| 10 | 0 | 1 | 0 | 1 |
| 11 | 1 | 0 | 0 | 1 |
| 15 | 2 | 0 | 0 | 2 |
| 20 | 0 | 1 | 0 | 1 |
| 25 | 0 | 2 | 0 | 2 |
| 30 | 2 | 0 | 0 | 2 |
| 50 | 3 | 4 | 0 | 7 |
| 54 | 0 | 1 | 0 | 1 |
| 57 | 0 | 1 | 0 | 1 |
| 75 | 1 | 2 | 0 | 3 |
| 99 | 1 | 0 | 0 | 1 |
| 7 to 9 | 1 | 0 | 0 | 1 |
1,811 of the 1,871 papers give no beam intensity.
Our equipment for this test
Our tail flick test's heat source runs from 20 to 100 W.
Download the values
tail-flick-settings.csv (141 KB) has one row per value a paper gives. Columns: pmcid, pmid, year, species, setting, value, unit, rules_version (the rules that read it) and release (the dated copy of PubMed Central's text the rules read). It holds no article text.
The tail flick test page gives the papers that name the test by year, and the questions researchers ask about it.
How we counted and checked
- How we found the papers
- Read from the Methods sections of open-access articles in PubMed Central, courtesy of the U.S. National Library of Medicine. The rules are patterns we wrote that find a test's name in the Methods, and each setting's value in a Methods sentence. A paper counts when its Methods say "tail flick", or name a tail withdrawal or tail immersion test, latency or assay.
- Papers counted and set aside
- 2,545 papers from 2011 to 2025 have "tail flick", "tail withdrawal" or "tail immersion" in their Methods or tables.
- 13 have it only in a table.
- 229 do not say "tail flick", nor name a tail withdrawal or tail immersion test, latency or assay.
- 10 mean something else, such as a tail flick in fish or larvae.
- 356 name the tail flick test only in Methods paragraphs that describe no animal work.
- 31 name neither mice nor rats anywhere in their Methods.
- 35 name mice and rats only outside the part of their Methods on the test, neither three times as often as the other.
- How the values were read
- Rules written for each setting read each value from a sentence in the part of the Methods that describes the test. A paper that repeats a value counts once for it. Each value gets the species named in its sentence, or else in its part of the Methods, or else in the paper. Some values go in the "One value, both species" column instead of the mouse or rat column. They are values a paper gives for mice and for rats, and values whose part of the Methods names both, neither three times as often as the other. Where the whole Methods name one species three times as often as the other, such a value goes to that species instead. The mouse and rat shares leave these values out. Water temperatures are read only where given in °C, and cut-offs only where given in seconds. A beam intensity keeps its own scale: a percent of full power, a number on the device's dial, or watts.
- How we checked them
- In two separate checks, an AI model found the same 32 of the 34 tail flick values right, and marked the same 2 wrong. The model, Claude Opus 5.5, checked them in November 2026 against the sentences they came from. A value counts as right when its number, unit, setting and species all match the sentence. We show a setting only when both checks find at least 9 in 10 of its checked values right. They were among 200 values drawn at random from the forced swim, light-dark box, tail flick and Hargreaves settings, and each check found 190 of the 200 right.
- Why the counts differ from the test page
- The tail flick test page counts the animal research papers in PubMed whose title or abstract names the test. This page reads only the open-access articles in PubMed Central that have a Methods section.
Show the values checked for each setting
| Setting | Values checked | Right in check 1 | Right in check 2 |
|---|---|---|---|
| Water temperature | 12 | 12 | 12 |
| Beam intensity | 10 | 9 | 9 |
| Cut-off time | 12 | 11 | 11 |