Research data ยท Settings in papers
Von Frey test settings
Our text-matching rules read the Methods of 8,437 open-access papers from 2011 to 2025 that name the von Frey test.
Which filament forces do von Frey papers give for mice and rats?
Most often 0.4 g for mice: 35% of the 2,457 mouse papers whose Methods give a filament force name it; 26% name 0.16 g. 15 g and 2 g lead almost equally for rats: 38% of the 2,019 rat papers whose Methods give a filament force name 15 g, and 37% name 2 g. A paper that gives a series counts once for each filament. In mouse papers, 9 in 10 of the forces given lie between 0.02 and 6 g. In rat papers, 9 in 10 lie between 0.4 and 60 g.
Papers by the filament force they give
The chart leaves out the 1,947 series given only as a range, lightest to heaviest filament: most often 0.008 to 2 g in mouse papers (117) and 0.4 to 15 g in rat papers (163).
Show the forces named by 10 or more papers
| Force | Mouse papers | Rat papers | One value, both species | All papers |
|---|---|---|---|---|
| 0.008 g | 207 | 28 | 0 | 235 |
| 0.02 g | 301 | 23 | 1 | 325 |
| 0.04 g | 368 | 26 | 1 | 395 |
| 0.07 g | 545 | 39 | 3 | 587 |
| 0.08 g | 22 | 2 | 0 | 24 |
| 0.1 g | 19 | 17 | 0 | 36 |
| 0.102 g | 13 | 0 | 0 | 13 |
| 0.16 g | 644 | 53 | 5 | 702 |
| 0.166 g | 13 | 3 | 0 | 16 |
| 0.2 g | 13 | 23 | 0 | 36 |
| 0.204 g | 13 | 0 | 0 | 13 |
| 0.25 g | 8 | 10 | 0 | 18 |
| 0.32 g | 16 | 1 | 0 | 17 |
| 0.38 g | 2 | 15 | 0 | 17 |
| 0.4 g | 852 | 345 | 8 | 1,205 |
| 0.45 g | 6 | 14 | 0 | 20 |
| 0.5 g | 9 | 12 | 0 | 21 |
| 0.57 g | 0 | 15 | 0 | 15 |
| 0.6 g | 517 | 276 | 4 | 797 |
| 0.69 g | 8 | 16 | 0 | 24 |
| 0.692 g | 8 | 15 | 0 | 23 |
| 0.7 g | 16 | 62 | 1 | 79 |
| 0.75 g | 2 | 10 | 0 | 12 |
| 0.8 g | 4 | 12 | 0 | 16 |
| 0.816 g | 14 | 5 | 0 | 19 |
| 1 g | 623 | 397 | 5 | 1,025 |
| 1.2 g | 14 | 98 | 1 | 113 |
| 1.202 g | 9 | 16 | 0 | 25 |
| 1.23 g | 0 | 16 | 0 | 16 |
| 1.3 g | 8 | 2 | 0 | 10 |
| 1.4 g | 375 | 271 | 4 | 650 |
| 1.479 g | 7 | 4 | 0 | 11 |
| 1.5 g | 4 | 12 | 0 | 16 |
| 1.632 g | 12 | 0 | 0 | 12 |
| 1.83 g | 0 | 15 | 0 | 15 |
| 2 g | 459 | 743 | 8 | 1,210 |
| 2.55 g | 0 | 10 | 0 | 10 |
| 2.8 g | 0 | 22 | 0 | 22 |
| 3 g | 14 | 2 | 0 | 16 |
| 3.263 g | 12 | 2 | 0 | 14 |
| 3.6 g | 0 | 31 | 0 | 31 |
| 3.63 g | 9 | 81 | 1 | 91 |
| 3.66 g | 0 | 15 | 0 | 15 |
| 4 g | 199 | 575 | 6 | 780 |
| 4.4 g | 0 | 10 | 0 | 10 |
| 5 g | 9 | 14 | 0 | 23 |
| 5.495 g | 0 | 17 | 0 | 17 |
| 5.5 g | 13 | 90 | 1 | 104 |
| 6 g | 105 | 553 | 3 | 661 |
| 8 g | 60 | 551 | 3 | 614 |
| 8.5 g | 4 | 61 | 0 | 65 |
| 8.51 g | 0 | 23 | 1 | 24 |
| 8.511 g | 0 | 18 | 0 | 18 |
| 9.13 g | 0 | 15 | 0 | 15 |
| 10 g | 54 | 423 | 3 | 480 |
| 10.5 g | 0 | 10 | 0 | 10 |
| 12 g | 2 | 8 | 0 | 10 |
| 12.237 g | 7 | 10 | 0 | 17 |
| 13.1 g | 0 | 15 | 0 | 15 |
| 15 g | 37 | 758 | 5 | 800 |
| 16 g | 0 | 10 | 0 | 10 |
| 18 g | 3 | 11 | 0 | 14 |
| 20 g | 5 | 22 | 0 | 27 |
| 25 g | 3 | 36 | 0 | 39 |
| 26 g | 19 | 398 | 2 | 419 |
| 28.84 g | 0 | 15 | 0 | 15 |
| 30 g | 0 | 17 | 0 | 17 |
| 40 g | 0 | 16 | 0 | 16 |
| 50 g | 4 | 52 | 0 | 56 |
| 60 g | 9 | 198 | 1 | 208 |
| 100 g | 6 | 73 | 0 | 79 |
| 180 g | 3 | 32 | 1 | 36 |
| 300 g | 5 | 44 | 1 | 50 |
| 0.007 to 6 g | 19 | 0 | 0 | 19 |
| 0.008 to 0.4 g | 10 | 1 | 0 | 11 |
| 0.008 to 1 g | 21 | 0 | 0 | 21 |
| 0.008 to 1.4 g | 29 | 1 | 0 | 30 |
| 0.008 to 2 g | 117 | 2 | 0 | 119 |
| 0.008 to 3.5 g | 22 | 0 | 0 | 22 |
| 0.008 to 4 g | 37 | 2 | 0 | 39 |
| 0.008 to 6 g | 35 | 1 | 0 | 36 |
| 0.008 to 300 g | 15 | 19 | 1 | 35 |
| 0.01 to 2 g | 16 | 0 | 0 | 16 |
| 0.02 to 1 g | 12 | 0 | 0 | 12 |
| 0.02 to 1.4 g | 39 | 0 | 0 | 39 |
| 0.02 to 2 g | 83 | 1 | 0 | 84 |
| 0.02 to 2.56 g | 71 | 2 | 0 | 73 |
| 0.02 to 4 g | 21 | 0 | 0 | 21 |
| 0.02 to 6 g | 6 | 4 | 0 | 10 |
| 0.03 to 2 g | 10 | 0 | 0 | 10 |
| 0.04 to 1.4 g | 16 | 1 | 0 | 17 |
| 0.04 to 2 g | 101 | 1 | 1 | 103 |
| 0.04 to 4 g | 27 | 0 | 1 | 28 |
| 0.07 to 2 g | 30 | 0 | 1 | 31 |
| 0.07 to 4 g | 20 | 0 | 0 | 20 |
| 0.16 to 2 g | 22 | 0 | 0 | 22 |
| 0.16 to 6 g | 15 | 1 | 0 | 16 |
| 0.16 to 26 g | 2 | 13 | 0 | 15 |
| 0.4 to 6 g | 17 | 0 | 0 | 17 |
| 0.4 to 15 g | 7 | 163 | 4 | 174 |
| 0.4 to 26 g | 0 | 45 | 0 | 45 |
| 0.4 to 60 g | 2 | 12 | 0 | 14 |
| 0.6 to 6 g | 18 | 0 | 1 | 19 |
| 0.6 to 15 g | 0 | 15 | 0 | 15 |
| 0.6 to 26 g | 0 | 31 | 1 | 32 |
| 1 to 15 g | 0 | 25 | 0 | 25 |
| 1 to 26 g | 0 | 23 | 0 | 23 |
| 1.4 to 26 g | 0 | 23 | 0 | 23 |
| 2 to 15 g | 0 | 24 | 0 | 24 |
| 2 to 26 g | 0 | 20 | 0 | 20 |
| 2 to 60 g | 1 | 23 | 0 | 24 |
| 637 rarer forces | 663 | 779 | 10 | 1,452 |
3,973 of the 8,437 papers give no filament force.
Which method do von Frey papers name?
50% of the 5,154 papers whose Methods name a method name up-down: 53% of mouse papers and 47% of rat papers. 25% name an electronic von Frey (an electronic or automated device in place of filaments). 22% name the ascending method (filaments applied in order of increasing force). 13% name a percent response (the share of withdrawals to a set number of applications). Rat papers name an electronic von Frey more often than mouse papers, 30% against 21%. The simplified up-down method is counted apart from up-down: 2% name it, and a paper that names both counts in each.
The von Frey test page also answers How do electronic von Frey and filaments differ?
Share of papers that name each method
Shares add to more than 100% because some papers name more than one method.
Show all methods
| Method | Mouse papers | Rat papers | One value, both species | All papers |
|---|---|---|---|---|
| up-down | 1,453 | 1,116 | 31 | 2,600 |
| electronic von Frey | 572 | 721 | 6 | 1,299 |
| ascending method | 507 | 608 | 6 | 1,121 |
| percent response | 457 | 191 | 3 | 651 |
| simplified up-down | 86 | 17 | 0 | 103 |
3,283 of the 8,437 papers name no method.
How many times do papers apply each filament?
Of the 807 papers that give how many times they apply each filament, 60% give 5, 20% give 10 and 16% give 3.
Papers by how many times they apply each filament
When a paper scores responses out of a set number of applications, that number is its count.
Show all counts
| Applications per filament | Mouse papers | Rat papers | One value, both species | All papers |
|---|---|---|---|---|
| 2 | 3 | 5 | 0 | 8 |
| 3 | 32 | 94 | 1 | 127 |
| 4 | 5 | 6 | 0 | 11 |
| 5 | 256 | 225 | 3 | 484 |
| 6 | 10 | 10 | 0 | 20 |
| 7 | 0 | 1 | 0 | 1 |
| 8 | 3 | 1 | 0 | 4 |
| 9 | 0 | 2 | 0 | 2 |
| 10 | 103 | 54 | 1 | 158 |
| 12 | 0 | 2 | 0 | 2 |
| 20 | 0 | 1 | 0 | 1 |
7,630 of the 8,437 papers give no count of applications.
Our equipment for this test
Our von Frey filaments run from 0.008 to 300 g. Our electronic von Frey reads forces from 0.08 to 2,940 mN, about 0.008 to 300 g.
Download the values
von-frey-settings.csv (1.8 MB) has one row per value a paper gives. Columns: pmcid, pmid, year, species, setting, value, unit, rules_version (the rules that read it) and release (the dated copy of PubMed Central's text the rules read). It holds no article text.
The von Frey test page gives the papers that name the test by year, and the questions researchers ask about it.
How we counted and checked
- How we found the papers
- Read from the Methods sections of open-access articles in PubMed Central, courtesy of the U.S. National Library of Medicine. The rules are patterns we wrote that find a test's name in the Methods, and each setting's value in a Methods sentence. A paper counts when its Methods name von Frey.
- Papers counted and set aside
- 9,369 papers from 2011 to 2025 have "von Frey", "Frey hairs" or "Frey filaments" in their Methods or tables.
- 7 have it only in a table.
- 36 do not write "von Frey" or "von-Frey".
- 44 name the von Frey test only in Methods paragraphs that describe no animal work.
- 708 name neither mice nor rats anywhere in their Methods.
- 137 name mice and rats only outside the part of their Methods on the test, neither three times as often as the other.
- How the values were read
- Rules written for each setting read each value from a sentence in the part of the Methods that describes the test. A paper that repeats a value counts once for it. Each value gets the species named in its sentence, or else in its part of the Methods, or else in the paper. Some values go in the "One value, both species" column instead of the mouse or rat column. They are values a paper gives for mice and for rats, and values whose part of the Methods names both, neither three times as often as the other. Where the whole Methods name one species three times as often as the other, such a value goes to that species instead. The mouse and rat shares leave these values out. Forces given in millinewtons are converted to grams, and an electronic device's readings are not counted as filament forces. Forces within 3% of a filament's nominal grams are shown as that filament; the download keeps each paper's own number. A paper counts for up-down when it names the method or cites Chaplan or Dixon. Up-down is Dixon's method (Dixon 1980), often as Chaplan et al. (1994) describe it: the stimulus oscillates around the response threshold. The simplified up-down method is the one Bonin et al. (2014) describe.
- How we checked them
- In two separate checks, an AI model found the same 48 of the 51 von Frey values right. The model, Claude Opus 5.5, checked them in November 2026 against the sentences they came from. A value counts as right when its number, unit, setting and species all match the sentence. We show a setting only when both checks find at least 9 in 10 of its checked values right. They were among 200 values drawn at random from the von Frey, elevated plus maze, formalin and catalepsy bar test settings, and each check found 192 of the 200 right. Catalepsy bar test values were in the draw; they don't show yet. After a fix to the force reader, a fresh draw of 25 force values came back 24 right in both checks.
- Why the counts differ from the test page
- The von Frey test page counts the animal research papers in PubMed whose title or abstract names the test. This page reads only the open-access articles in PubMed Central that have a Methods section.
- Papers cited
- Dixon WJ (1980). Efficient analysis of experimental observations. Annual Review of Pharmacology and Toxicology. PMID 7387124. Chaplan SR, Bach FW, Pogrel JW, et al. (1994). Quantitative assessment of tactile allodynia in the rat paw. Journal of Neuroscience Methods. PMID 7990513. Bonin RP, Bories C, De Koninck Y (2014). A simplified up-down method (SUDO) for measuring mechanical nociception in rodents using von Frey filaments. Molecular Pain. PMID 24739328.
Show the values checked for each setting
| Setting | Values checked | Right in check 1 | Right in check 2 |
|---|---|---|---|
| Filament force | 25 | 23 | 23 |
| Filament force, fresh draw after the fix | 25 | 24 | 24 |
| Method | 15 | 15 | 15 |
| Applications per filament | 11 | 10 | 10 |