Commercial Dehumidifier 90L 138L
High-capacity commercial dehumidifier removing 90L moisture per day with adjustable humidity control from 10-90% RH for research facilities up to 150 square meters.
| Automation Level | semi-automated |
| Humidity Removal Capacity | 90L/24H (BKDH-890D), 138L/24H (BKDH-8138D) |
| Humidity Adjusted Range | 10%~90%RH |
| Refrigerant | R410A |
| Applying Area | 90~150m2 (BKDH-890D), 130~180m2 (BKDH-8138D) |
| Consumption | 1300W (BKDH-890D), 1500W (BKDH-8138D) |
The Commercial Dehumidifier 90L 138L is a high-capacity environmental control system designed for research facilities requiring precise humidity management. This unit removes up to 90 liters of moisture per 24-hour period while maintaining adjustable humidity levels between 10% and 90% relative humidity across areas up to 150 square meters.
Built with cold rolled plate coating construction and utilizing R410A refrigerant, this dehumidifier provides reliable environmental control for laboratories, storage areas, and research facilities where consistent humidity conditions are critical for experimental protocols and equipment protection. The unit operates on standard laboratory power requirements with optional voltage configurations to accommodate different facility specifications.
How It Works
This commercial dehumidifier operates on the refrigeration principle using R410A refrigerant to condense water vapor from ambient air. The system draws humid air through an evaporator coil where moisture condenses as the air temperature drops below its dew point. The condensed water is collected in a reservoir while the dried air passes over a condenser coil to return to room temperature before being circulated back into the environment.
The unit maintains precise humidity control through an integrated sensor system that monitors ambient relative humidity levels and automatically cycles the refrigeration system to maintain setpoint conditions. The adjustable range of 10% to 90% relative humidity allows researchers to establish specific environmental conditions required for their protocols or equipment specifications.
Features & Benefits
Automation Level
- semi-automated
Humidity Removal Capacity
- 90L/24H (BKDH-890D)
- 138L/24H (BKDH-8138D)
Humidity Adjusted Range
- 10%~90%RH
Refrigerant
- R410A
Applying Area
- 90~150m2 (BKDH-890D)
- 130~180m2 (BKDH-8138D)
Consumption
- 1300W (BKDH-890D)
- 1500W (BKDH-8138D)
Air Circulation
- 1100 m3/h (BKDH-890D)
- 1200 m3/h (BKDH-8138D)
Material
- Cold rolled plate coating
Power/Voltage
- Standard: 220V, 50Hz; Optional: 110V, 60Hz
External Size (W*D*H)
- 480x420x960mm (BKDH-890D)
- 480x420x1060mm (BKDH-8138D)
Packing Size (W*D*H)
- 550x470x1060mm (BKDH-890D)
- 550x470x1150mm (BKDH-8138D)
Net Weight
- 50kg (BKDH-890D)
- 60kg (BKDH-8138D)
Gross Weight
- 55kg (BKDH-890D)
- 65kg (BKDH-8138D)
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Environmental Monitoring
- Food Science
- Materials Science
- Microbiology
- Pharmaceutical QC
Weight
- 50.0 kg
Dimensions
- L: 96.0 mm
- W: 48.0 mm
- H: 42.0 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Moisture Removal Capacity | 90L per 24 hours | Entry-level units often provide 30-50L daily capacity | Higher capacity reduces maintenance frequency and handles larger facility humidity loads effectively |
| Coverage Area | 90-150 square meters | Smaller units typically cover 50-80 square meters | Broader coverage allows single-unit environmental control for entire laboratory sections |
| Humidity Range | 10-90% RH adjustable | Basic models often limited to 30-80% RH range | Extended range accommodates both dry storage requirements and controlled humidity protocols |
| Power Requirements | Dual voltage: 220V/50Hz or 110V/60Hz | Most units fixed to single voltage configuration | Installation flexibility accommodates different facility power systems without modification |
| Construction Material | Cold rolled plate coating | Consumer units often use standard painted steel | Enhanced corrosion resistance extends service life in laboratory chemical environments |
This unit offers commercial-grade moisture removal capacity with broad humidity control range and dual voltage capability for research facility installation. The robust construction and high-capacity operation provide reliable environmental control for demanding laboratory applications.
Practical Tips
Verify humidity sensor accuracy using calibrated reference instruments at multiple setpoints within your operating range.
Why: Sensor drift over time can affect environmental control precision for sensitive experiments.
Clean air intake filters monthly and inspect condensate drainage for blockages during routine facility maintenance.
Why: Restricted airflow reduces dehumidification efficiency and can cause system cycling problems.
Position unit away from heat sources and ensure adequate air circulation around intake and exhaust vents.
Why: Proper airflow maximizes the effective coverage area and prevents hot spots that reduce efficiency.
If humidity control becomes erratic, check for air leaks in the controlled space and verify drainage system function.
Why: External humidity sources and drainage problems are common causes of apparent equipment malfunction.
Monitor both inlet and outlet air conditions to verify system performance matches facility requirements.
Why: Independent monitoring confirms the unit is achieving target conditions across the full coverage area.
Ensure electrical connections match the unit's voltage requirements (220V/50Hz or 110V/60Hz) and provide appropriate circuit protection.
Why: Incorrect voltage can damage the refrigeration system and create safety hazards.
Setup Guide
What’s in the Box
- Commercial dehumidifier main unit
- Power cord
- Condensate drain fittings (typical)
- Operation manual
- Installation guide (typical)
Warranty
ConductScience provides standard manufacturer warranty coverage with technical support for installation guidance and operational troubleshooting. Extended service plans available for critical facility applications requiring guaranteed uptime.
Compliance
What is the humidity control accuracy and response time for setpoint changes?
The unit maintains adjustable humidity between 10-90% RH with automatic cycling. Consult product datasheet for specific control accuracy and response time parameters.
How does the 1300W power consumption compare to facility electrical capacity requirements?
The unit draws 1300W on either 220V/50Hz (standard) or 110V/60Hz (optional) power systems. Verify facility circuit capacity can support continuous operation at this load level.
What maintenance schedule is required for the R410A refrigerant system?
R410A systems typically require annual professional service for refrigerant level checks and coil cleaning. Follow manufacturer maintenance protocols for optimal performance.
Can multiple units be coordinated for larger facility coverage beyond 150 square meters?
Each unit covers 90-150 square meters independently. Multiple units can be installed for larger areas, though coordination systems may require separate environmental controls.
How does ambient temperature affect the 90L/24H removal capacity?
Dehumidification capacity varies with ambient temperature and initial humidity levels. Consult product datasheet for capacity curves at specific operating conditions.
What condensate drainage options are available for continuous operation?
The unit requires drainage system for the 90L daily condensate removal. Options include gravity drain connections or condensate pumps for facilities without floor drainage.
Is the cold rolled plate coating compatible with laboratory chemical environments?
Cold rolled plate coating provides corrosion resistance for typical laboratory environments. Evaluate compatibility with specific chemical exposures in your facility.
Does the commercial dehumidifier come with a drain pipe?
Yes. The BKDH-890D and BKDH-8138D commercial dehumidifiers include a drain pipe for continuous drainage.
What is the noise level of the commercial dehumidifier during operation?
The noise level is approximately 55 dB during normal operation.