Home dehumidifier
Professional laboratory dehumidifier with 50L/24H capacity and 40-90% RH adjustable control for environmental conditioning in research settings.
| Automation Level | semi-automated |
| BKDH-860D | BKDH-860E |
| Humidity Removal Capacity | 50L/24H |
| Humidity Adjusted Range | 40%~90%RH |
| Refrigerant | R410A |
| Consumption | 700W |
The ConductScience Home Dehumidifier (BIO-0816) is a professional-grade humidity control system designed for laboratory and research environments requiring precise moisture management. This unit provides 50L/24H dehumidification capacity with adjustable humidity control ranging from 40% to 90% relative humidity, enabling researchers to maintain optimal environmental conditions for sensitive experiments, sample storage, and equipment operation.
Built with ABS construction and featuring a 10L water collection tank, this dehumidifier operates on standard laboratory power supplies (220V 50Hz standard, 110V 60Hz optional) with 700W power consumption. The compact footprint (436×290×720mm) and 23.5kg weight make it suitable for placement in various laboratory settings where environmental humidity control is critical for experimental reproducibility and equipment protection.
How It Works
The dehumidifier operates on the refrigeration condensation principle using R410A refrigerant. Humid air is drawn over a cold evaporator coil where water vapor condenses into liquid droplets that collect in the 10L reservoir tank. The dried air then passes over a warm condenser coil before being returned to the environment, effectively reducing ambient humidity levels.
The system continuously monitors ambient humidity through internal sensors and automatically cycles the compressor and fan systems to maintain the user-selected humidity setpoint within the 40-90% RH range. The 700W power consumption provides sufficient cooling capacity to remove up to 50 liters of moisture per 24-hour period under standard laboratory conditions.
Features & Benefits
Automation Level
- semi-automated
BKDH-860D
- BKDH-860E
Humidity Removal Capacity
- 50L/24H
Humidity Adjusted Range
- 40%~90%RH
Refrigerant
- R410A
Consumption
- 700W
Water Tank
- 10L
External Size(W*D*H)
- 436*290*720mm
Packing Size(W*D*H)
- 490*350*780mm
Border Color
- Black
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Clinical Diagnostics
- Environmental Monitoring
- Materials Science
- Microbiology
- Pharmaceutical QC
Material
- ABS
Power/Voltage
- Standard: 220V, 50Hz; Optional: 110V, 60Hz
Weight
- 26kg
Weight
- 23.5 kg
Dimensions
- L: 72.0 mm
- W: 43.6 mm
- H: 29.0 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Daily Moisture Removal | 50L/24H capacity | Entry-level units often provide 20-30L/24H capacity | Higher capacity supports larger laboratory spaces and continuous high-humidity research applications |
| Humidity Control Range | 40-90% RH adjustable | Basic models may offer limited setpoint options | Wide control range accommodates diverse experimental requirements and storage conditions |
| Water Collection Capacity | 10L collection tank | Smaller units typically have 2-5L tanks | Larger tank reduces maintenance frequency and supports extended unattended operation |
| Power Configuration | Dual voltage (220V/110V) capability | Single voltage configuration common | Flexible installation options for international laboratory facilities with different power systems |
| Construction Material | ABS housing construction | Varies by model, some use metal construction | Chemical resistance suitable for laboratory environments with potential chemical exposure |
This dehumidifier provides professional-grade moisture removal capacity with precise humidity control and large water collection capacity. The dual voltage capability and chemical-resistant construction make it particularly suitable for diverse laboratory installations and research environments.
Practical Tips
Verify humidity setpoints using a calibrated hygrometer placed near the unit's air intake to ensure accurate environmental control.
Why: Independent verification ensures the internal humidity sensor is providing accurate readings for experimental reproducibility.
Clean the water collection tank weekly with mild detergent to prevent bacterial growth and maintain hygiene standards.
Why: Regular cleaning prevents biofilm formation that could affect air quality and unit performance.
Position the unit away from direct air currents and heat sources to ensure stable humidity readings and efficient operation.
Why: Stable air flow patterns around the unit improve humidity control accuracy and prevent cycling inefficiencies.
If humidity levels are not reaching setpoint, check that all air intake and exhaust areas are unobstructed and filters are clean.
Why: Restricted airflow reduces dehumidification efficiency and prevents the unit from achieving target humidity levels.
Allow 30-60 minutes after startup for humidity levels to stabilize before beginning humidity-sensitive experiments.
Why: Initial equilibration time ensures consistent environmental conditions throughout the experimental period.
Ensure the unit remains upright during transport and allow 2 hours settling time before operation after any movement.
Why: Refrigerant systems require settling time to prevent compressor damage and ensure proper operation.
Monitor water tank levels during extended experiments to prevent overflow and maintain continuous humidity control.
Why: Full water tanks can cause automatic shutdown, interrupting environmental control during critical experimental periods.
Setup Guide
What’s in the Box
- Dehumidifier main unit
- 10L water collection tank
- Power cord
- User manual
- Warranty documentation
Warranty
ConductScience provides a standard 1-year manufacturer warranty covering defects in materials and workmanship, with technical support for installation and operational guidance.
Compliance
What is the operating humidity range and accuracy of the control system?
The unit provides adjustable humidity control from 40% to 90% RH. Consult product datasheet for specific control accuracy specifications.
How frequently does the 10L water tank require emptying under typical laboratory conditions?
Tank emptying frequency depends on ambient humidity and set point. At maximum 50L/24H capacity, the tank would require emptying approximately 5 times per day under high-load conditions.
Is the unit suitable for continuous 24/7 operation in laboratory environments?
Yes, the unit is designed for continuous operation with automatic humidity control and large water tank capacity to minimize intervention requirements.
What maintenance procedures are required for optimal performance?
Regular maintenance includes water tank cleaning, air filter inspection/replacement, and coil cleaning. Consult user manual for specific maintenance intervals.
Can the unit operate effectively in temperature-controlled laboratory environments?
The unit is designed for indoor laboratory use. Consult product specifications for specific operating temperature range and performance characteristics.
Does the dehumidifier provide any monitoring or alarm functions?
Basic operational status is indicated. Consult product datasheet for specific monitoring capabilities and alarm functions available.
How does this compare to desiccant-based humidity control systems?
Refrigeration-based systems like this unit provide continuous moisture removal without consumable materials, while desiccant systems may offer lower humidity levels but require regeneration or replacement.