SP60-4x Four-Channel Industrial Syringe Pump
The SP60-4x is a precision four-channel industrial syringe pump offering exceptional volumetric accuracy (≤1.0%) and repeatability (≤0.05%). Designed for demanding laboratory applications with chemical-resistant fluid paths and robust ball screw t...
Overview
The SP60-4x Four-Channel Industrial Syringe Pump is a precision liquid handling instrument designed for demanding laboratory and industrial applications. This advanced syringe pump delivers exceptional accuracy and reliability for controlled fluid dispensing, making it ideal for research environments where precise volume control is critical. Note: This unit is classified as industrial equipment and is not subject to medical device regulations.
Key Features
Featuring four independent channels, this pump enables simultaneous multi-fluid operations with outstanding volumetric accuracy of ≤1.0% for 1ml syringes and above. The system achieves remarkable precision with repeatability error ≤0.05% across full stroke for 500μl syringes and above. The robust ball screw transmission mechanism ensures smooth, consistent operation over extended periods. All fluid contact materials are constructed from high-purity borosilicate glass and premium fluoropolymers including PTFE, PFA, CTFE, ETFE, and UHMW-PE, providing excellent chemical compatibility and contamination resistance.
Applications
This industrial syringe pump excels in analytical chemistry, materials research, catalyst testing, and process development applications. The multiple channels make it particularly suitable for gradient mixing, reaction optimization studies, and automated sample preparation workflows. The chemical-resistant fluid path materials enable safe handling of aggressive solvents and reactive compounds commonly used in advanced research applications.
Weight
- 3.0 kg
Dimensions
- L: 198.1 mm
- W: 154.1 mm
- H: 96.9 mm
Specifications
| Specification | Value |
|---|---|
| Number of Channels | 4 |
| Volumetric Accuracy | ≤1.0% (1ml syringe and above) |
| Volumetric Precision | Repeatability error ≤0.05% (full stroke, 500μl syringe and above) |
| Fluid Path Materials | Borosilicate glass, PTFE, PFA, CTFE, ETFE, UHMW-PE |
| Syringe Connection | 1/4"-28 internal thread |
| Tubing Connection | 1/4"-28 internal thread |
| Rated Stroke | 60mm |
| Drive Mechanism | Ball screw transmission |
Frequently Asked Questions
What is the maximum volumetric accuracy of this syringe pump?
The SP60-4x achieves volumetric accuracy of ≤1.0% for 1ml syringes and above, with precision repeatability error of ≤0.05% across full stroke for 500μl syringes and above.
What materials are used in the fluid path construction?
The fluid path is constructed from high-purity borosilicate glass and premium fluoropolymers including PTFE, PFA, CTFE, ETFE, and UHMW-PE, ensuring excellent chemical compatibility and contamination resistance.
Can this pump be used for medical applications?
No, the SP60-4x is classified as industrial equipment and is not intended for medical device applications. It is designed specifically for laboratory and industrial research use.
No Q&A yet. Have a question? Ask below.