Gas Chromatograph with Electronic Pressure Control
Benchtop GC supporting up to four simultaneous detectors, with self-diagnosis and carrier-gas saving.

Louise Corscadden, PhD
Director of Science · ConductScience
Ask Louise about Gas Chromatograph with Electronic Pressure Control fit, setup, configuration, or quote prep.
Already working with us? Sign in to connect this with My Scientist.
Key Specifications
Full details →- Model fit
- Configured during quote
- SKU family
- CS-ANL-00017
- Sizing
- Model-specific dimensions confirmed from the selected configuration
- Ordering
- Quote-reviewed before fulfillment
- Category
- Chromatography
- Build notes
- Confirm accessories, station layout, and support needs before purchase
A gas chromatograph for routine and method-development work. Electronic flow and pressure control on both inlet and detector hold retention times across ambient swings, and up to four detectors can be mounted at once so a method can be developed without re-plumbing the instrument.
Key features
- Robust liquid inlet.
- High precision EPC.
- Great column oven.
- Easy-to-use workstation software.
- Excellent humancomputer interaction experience.
- Support multiple detector options (up to four at the same time).
- Ultra-stable liquid injection port
- Fully electronic flow control is adopted with a self-diagnostic function and no need for manual soap leak detection, reducing the risk of system contamination.
Applications
Built for environmental, petrochemical and food laboratories.
- Food safety: Detection of food additives,food residues, contaminants, illegal additives.
- Environmental monitoring: Monitoring and analysis of environmental pollutants.
- Environment and health - NMTH analysis solutions
- Environment and health - VOC analysis solutions
- Food safety - Multi-residue analysis solutions for pesticides in vegetables and fruits
- Food safety - Multiple pesticide residue analysis solutions for food
Choosing the right configuration
Choose the inlet or autosampler, column format, detector or ion source, carrier or source gases, vacuum hardware, and data workflow around the analytes and expected sample throughput. ConductScience confirms the complete configuration during method and site review.
Features & Benefits
Retention-time repeatability
- <0.008%
Peak-area repeatability
- <0.5%
Injection-port capacity
- up to two injection ports
Detector capacity
- up to four detectors
Detector-signal capacity
- three detector signals
Electronic flow-control capacity
- up to 6 modules and 18 gas circuits
Pressure-control accuracy
- ±0.001 psi
Column-oven dimensions
- 28 × 31 × 16 cm
Column capacity
- up to 3 capillary columns
Column-oven temperature range
- room temperature +4°C to 450°C
Temperature-setting accuracy
- ≤0.1°C
Maximum heating rate
- ≥120°C/min
Oven program
- 32 heating gradients and 33 constant-temperature platforms
Maximum run time
- 999.99 min
Oven cooling rate
- 6 minutes from 450°C to 50°C at 20°C room temperature
Ambient-temperature sensitivity
- 1°C ambient change produces <0.01°C average oven change
Carrier and makeup gases
- N₂, He, H₂
Carrier-gas flow stability
- less than 1%/10 min
Touch screen
- 8-inch, 1280 × 720, 16.7M colors
Compatible capillary-column inner diameter
- 0.1 mm-0.53 mm
Maximum split ratio
- 12500:1
Injection-port temperature
- up to 450°C
Injection-port flow range
- 0-500 mL/min (N₂); 0-1000 mL/min (H₂ or He)
FID detection limit
- <5.0×10⁻¹² g C/s
FID linear dynamic range
- 10⁷
ECD detection limit
- <3.8×10⁻¹⁴ g/mL
ECD linear range
- 10⁴
FPD detection limit
- <9×10⁻¹⁴ g/s (P); <5×10⁻¹² g/s (S)
FPD linear range
- ≥10⁴ (P); ≥10³ (S)
Operating ambient temperature
- 5°C-35°C
Operating ambient humidity
- 5%-95%
Storage temperature
- -40°C to 70°C
Power supply
- AC 220 (±10%) V; 50 (±10%) Hz
Dimensions
- 486 × 556.4 × 558 mm
Weight
- 38.1 kg
What does this instrument measure, and who is it for?
It measures volatile and semi-volatile compounds separated by gas chromatography and measured with the selected detector. It is built for environmental, petrochemical and food laboratories. It is intended for continuous laboratory duty, with a plumbed gas supply, a sited vacuum pump and a defined solvent-waste route.
What measurement principle does it use?
The column separates compounds as a controlled carrier-gas stream moves them through the oven. The selected detector then measures each compound as it elutes, with electronic pressure and flow control maintaining the chromatographic conditions across the sequence.
Which specifications are confirmed?
The specification table lists thirty-five confirmed ordering parameters for this instrument. Use them to compare the operating range, utilities, and analytical performance required by the method. They include Retention-time repeatability at <0.008%, Peak-area repeatability at <0.5% and Electronic flow-control capacity at up to 6 modules and 18 gas circuits.
What should be confirmed before ordering?
Confirm carrier and collision gas supply, siting and noise of the vacuum pump, solvent handling and waste routing, and the column and ion-source selection your method needs. These are configured and quoted per installation, so raise anything unusual about the site during quote review rather than after delivery.
What else is needed to run it?
Carrier and collision gas of the specified purity, a vacuum pump sited for its noise and heat, and the consumables your method consumes. These are not yet listed as products; specify them during quote review.
How is it supplied?
This instrument is configured and quoted per installation rather than sold at a list price. Request a quote and we will confirm the configuration, the site requirements and the lead time before anything is ordered.
Have a question about this product?
Have a question? Just ask.
Send it over and we'll email you a personalized answer — no call, no scheduling.
Prefer to talk it through?