TSP01-02A Dual-Channel Microfluidic Syringe Pump System
Professional dual-channel microfluidic syringe pump system with 5-inch touchscreen control and independent channel configuration. Supports syringe volumes from 10μL to 60mL with precise flow control from 3μm/min to 130mm/min.
Overview
The TSP01-02A is a professional dual-channel microfluidic syringe pump system designed for precise fluid delivery in laboratory applications. This split-type pump features independent channel configuration with touchscreen control, delivering exceptional accuracy and reliability for microfluidic experiments and automated fluid handling processes.
Key Features
The system supports dual-channel independent operation with a maximum stroke of 90mm and rated linear thrust ≥16kgf. Multiple operating modes include infusion, withdrawal, infusion-then-withdrawal, withdrawal-then-infusion, and continuous operation. The pump accommodates syringe volumes from 10μL to 60mL with precise linear velocity control ranging from 3μm/min to 130mm/min. The 5-inch touchscreen interface provides intuitive full-touch operation with stroke control accuracy within ±0.5% error tolerance.
Applications
Ideal for microfluidic research, cell culture perfusion, drug delivery studies, chemical synthesis, and automated sample preparation. The system's precise flow control and dual-channel capability make it perfect for complex experimental protocols requiring synchronized or independent fluid delivery. Applications include organ-on-chip studies, droplet generation, gradient formation, and multi-reagent mixing experiments in pharmaceutical, biotechnology, and academic research environments.
Weight
- 4.5 kg
Dimensions
- L: 302.0 mm
- W: 251.7 mm
- H: 170.6 mm
Specifications
| Specification | Value |
|---|---|
| Control Method | Touchscreen controller or external control |
| Number of Channels | 2 (independent configuration) |
| Maximum Stroke | 90mm |
| Rated Linear Thrust | ≥16kgf |
| Operating Modes | Infusion, withdrawal, infusion-then-withdrawal, withdrawal-then-infusion, continuous |
| Execution Units | 1 or 2 |
| Syringe Compatibility | 10μL to 60mL |
| Linear Velocity Range | Min: 3μm/min, Max: 130mm/min |
| Stroke Control Accuracy | Error ≤±0.5% |
| Operation Modes | Independent and coordinated |
| Display | 5-inch touchscreen |
| Operation Method | Full touch operation |
Frequently Asked Questions
What syringe sizes are compatible with this pump?
The TSP01-02A accommodates syringes from 10μL to 60mL, providing versatility for various experimental volumes and flow rate requirements.
Can the two channels operate independently?
Yes, the system supports both independent and coordinated operation modes, allowing each channel to run different protocols simultaneously or work together in synchronized applications.
What is the accuracy of the flow control?
The pump delivers stroke control precision within ±0.5% error tolerance, with linear velocity control ranging from 3μm/min to 130mm/min for precise microfluidic applications.
No Q&A yet. Have a question? Ask below.