Multi-position Magnetic Stirrer
Six-position magnetic stirrer with DC brushless motor system providing simultaneous mixing from 50-1600 rpm with programmable timing up to 99 hours.
| Automation Level | semi-automated |
| Motor Type | DC brushless motor |
| Maximum Volume | 1L*6 |
| Rotation Range | 50~1600rpm |
| Timing Range | 0~99h59min |
| Working Plate Size | 369*269mm |
The Multi-position Magnetic Stirrer provides simultaneous stirring for up to six vessels with independent speed control across positions. The unit employs a DC brushless motor system delivering consistent rotation from 50 to 1600 rpm across a 369×269 mm working plate. The integrated timer function supports extended protocols up to 99 hours and 59 minutes, enabling unattended operation for lengthy mixing procedures.
The 25W stirring power accommodates vessels up to 1L capacity per position, suitable for diverse laboratory mixing applications including buffer preparation, sample homogenization, and solution preparation. The unit operates within ambient conditions of 5-40°C and up to 80% humidity, providing reliable performance in standard laboratory environments.
How It Works
The multi-position magnetic stirrer operates through electromagnetic field generation beneath each stirring position on the working plate. When a magnetic stir bar is placed in a vessel above each position, the rotating electromagnetic fields cause the stir bars to rotate synchronously. The DC brushless motor system provides precise speed control and eliminates maintenance issues associated with brushed motors.
Each position generates an independent magnetic field, allowing different vessels to be stirred at the same speed setting while maintaining consistent rotation across all active positions. The 25W power output distributes across active positions, providing sufficient magnetic coupling for stir bars up to standard laboratory sizes in vessels containing up to 1L volume per position.
Features & Benefits
Automation Level
- semi-automated
Motor Type
- DC brushless motor
Maximum Volume
- 1L*6
Rotation Range
- 50~1600rpm
Timing Range
- 0~99h59min
Working Plate Size
- 369*269mm
Ambient Temp.
- 5~40℃
Ambient Humidity
- 80%
Stirring Power
- 25W
External Size(L*W*H)
- 370*353*121mm
Package Size(L*W*H)
- 492*382*219mm
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Cell Biology
- Clinical Diagnostics
- Environmental Monitoring
- Food Science
- Materials Science
- Microbiology
- Pharmaceutical QC
Power/Voltage
- AC110~220V, 50/60Hz
Weight
- 6.3kg
Weight
- 4.85 kg
Dimensions
- L: 12.1 mm
- W: 37.0 mm
- H: 35.3 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Number of Positions | Six simultaneous stirring positions | Entry-level models often offer 1-4 positions | Enables parallel processing of multiple samples under identical conditions, reducing protocol time and improving reproducibility. |
| Motor Type | DC brushless motor system | Many units use brushed motors requiring periodic maintenance | Eliminates brush replacement and provides consistent performance over extended operational periods. |
| Timer Range | Up to 99 hours 59 minutes | Basic models often limited to hours or require manual monitoring | Accommodates extended protocols including overnight procedures without operator supervision. |
| Power Output | 25W total stirring power | Lower-end models typically offer 15-20W | Maintains effective magnetic coupling across all positions even with larger vessels or higher viscosity samples. |
| Working Plate Size | 369×269 mm working surface | Compact models often have smaller working areas | Accommodates various vessel sizes and configurations while maintaining organized workspace layout. |
| Volume Capacity | 1L maximum per position (6L total) | Multi-position units often limited to smaller vessels | Handles standard laboratory volumes for most analytical and preparative procedures across all positions. |
This multi-position stirrer combines high-capacity parallel processing with brushless motor reliability and extended timing capability. The 25W power output and large working plate accommodate diverse laboratory mixing requirements while the 99-hour timer supports extended protocols.
Practical Tips
Verify speed accuracy using a tachometer or strobe light at regular intervals, particularly at commonly used speed settings.
Why: Ensures consistent mixing parameters across protocols and between different experimental sessions.
Clean the working plate surface regularly with appropriate solvents to remove chemical residues that could affect magnetic coupling.
Why: Chemical buildup can create distance between vessel and magnetic field, reducing stirring efficiency.
Start stirring at low speeds and gradually increase to prevent stir bar decoupling and solution splashing.
Why: Prevents sample loss and ensures stable magnetic coupling throughout the mixing protocol.
Use stir bars approximately one-third to one-half the diameter of the vessel bottom for optimal mixing efficiency.
Why: Proper stir bar sizing ensures effective solution movement without excessive turbulence or vessel contact.
If stir bars decouple frequently, check for ferromagnetic interference from nearby equipment or vessel materials.
Why: External magnetic fields or ferromagnetic materials can disrupt the coupling between motor and stir bar.
Ensure vessels are stable and properly centered before starting operation, especially when using the timer function.
Why: Prevents vessel displacement during extended unattended operation that could lead to spills or equipment damage.
Document stirring speed and duration as part of protocol parameters for reproducible results across experiments.
Why: Mixing conditions significantly affect solution homogeneity and can impact experimental outcomes and reproducibility.
Inspect stir bars regularly for chips or deformation that could affect mixing performance or damage vessels.
Why: Damaged stir bars create uneven mixing patterns and may scratch glassware or create sample contamination.
Setup Guide
What’s in the Box
- Multi-position magnetic stirrer main unit
- Power cord
- User manual and technical documentation
- Magnetic stir bar set (typical)
- Calibration certificate (typical)
Warranty
ConductScience provides a standard one-year manufacturer warranty covering defects in materials and workmanship. Technical support includes operation guidance and calibration procedures.
Compliance
References
Background reading relevant to this product:
Can different positions be operated at different speeds simultaneously?
All positions operate at the same speed setting. The unit provides uniform stirring across all active positions but does not offer independent speed control per position.
What is the maximum stir bar size that maintains coupling?
Consult product datasheet for specific stir bar compatibility. Generally, standard laboratory stir bars up to vessel diameter maintain coupling with the 25W power output.
How does the timer function operate during power interruption?
Timer settings are not retained during power interruption. Protocols requiring uninterrupted timing should include backup power considerations.
What vessel materials are compatible with magnetic stirring?
Non-magnetic materials including glass, plastic, and ceramic vessels are compatible. Avoid ferromagnetic containers that interfere with magnetic field transmission.
Can the unit handle viscous solutions effectively?
The 25W power output accommodates moderate viscosity solutions. Very viscous samples may require lower speeds to maintain stir bar coupling or alternative mixing methods.
What maintenance is required for the brushless motor system?
Minimal maintenance required due to brushless design. Regular cleaning of the working plate and periodic inspection of magnetic coupling performance are recommended.
Are replacement parts available for long-term use?
Standard replacement components including stir bars and accessories are typically available. Contact ConductScience for specific part availability and compatibility.