Triple Quadrupole ICP-MS/MS System
Tandem ICP-MS/MS with a five-channel collision/reaction cell for interference-limited trace analysis.

Louise Corscadden, PhD
Director of Science · ConductScience
Ask Louise about Triple Quadrupole ICP-MS/MS System fit, setup, configuration, or quote prep.
Already working with us? Sign in to connect this with My Scientist.
Key Specifications
Full details →- SKU family
- CS-ANL-00023
- Ordering
- Quote-reviewed before fulfillment
- Category
- Analytical Instruments
A tandem quadrupole ICP-MS that places a reaction cell between two mass filters, resolving the polyatomic overlaps that defeat single-quadrupole instruments. Suited to high-purity materials, semiconductor process chemicals and rare-earth work where the analyte sits under a stubborn interference.
Key features
- Vertical ion optics and dual deflection design effectively remove neutral species, reducing background and improving detection accuracy.
- Robust torch and ion optics design allow direct analysis of high-salt and volatile samples with excellent stability.
- A pre-cell quadrupole (Q1) filters out unwanted ions before the collision/reaction cell, enabling ppt-level detection even for challenging elements like phosphorus and sulfur.
- Compatible with autodigestion, chromatography, solid/gas injection systems for expanded application flexibility.
- Intelligent gas control and low-power standby mode reduce argon consumption by over 50%.
- Highly sensitive electron multiplier
- Triple quadrupole design
- Right-angle ion optics
Applications
Built for high-purity materials and semiconductor laboratories.
- Food safety
- Environmental monitoring
- Clinical
- Alloy steel
- environmental, food, life science, and semiconductor fields
- The combination of ultra-high performance liquid chromatography and ICP-MS technology can realize the speciation and valence analysis of mercury, tin, lead, arsenic and chromium in samples.
- customized method packages are provided for monitoring and on-line analysis in semiconductor and other fields
Choosing the right configuration
Match the sample matrix and target elements to the required detection limits, sample-introduction hardware, gas supply, exhaust, cooling, and data-system configuration. ConductScience confirms these items against the proposed method before the system is quoted.
Features & Benefits
The manufacturer does not publish a specification table for this instrument. The figures below are quoted from its technical literature and have not been independently verified. Request the engineering datasheet for confirmed values.
| Mass resolution | the mass resolution of less than 0.3amu |
|---|---|
| Intelligent sample dilution | Intelligent sample dilution, up to 200 times on-line dilution |
| Right-angle ion optics background reduction | reduce the background by more than 5 times |
| Vacuum system | Three turbomolecular pumps and five-stage vacuum design |
| Abundance sensitivity improvement | increases the abundance sensitivity by more than two orders of magnitude |
What does this instrument measure, and who is it for?
It measures trace metals that sit underneath a polyatomic interference a single quadrupole cannot resolve. It is built for high-purity materials and semiconductor laboratories. It is a benchtop instrument intended for continuous laboratory duty, with a plumbed gas supply and extraction over the source.
What measurement principle does it use?
A reaction cell sits between two mass filters. The first selects the analyte mass, the cell shifts or removes the interference, the second measures what is left, which is how an overlap that defeats a single quadrupole is resolved rather than merely tolerated.
What performance details are available for selection?
The available product literature describes the measurement architecture and supported workflows, but a configuration-specific engineering sheet is still required for final method selection. ConductScience will include that document in quote review before the configuration is approved.
Can this system be selected for an established method?
Select it only after the engineering sheet is checked against the method's required detection limits, stability, matrix tolerance, acquisition modes, and site conditions. ConductScience will document that comparison during quote review so the ordered configuration matches the method.
What else is needed to run it?
A microwave digestion system, unless your samples already arrive in solution. Elemental analysis is only as good as the dissolution that preceded it, and an incomplete digest reports a low result with no indication that anything went wrong.
How is it supplied?
This instrument is configured and quoted per installation rather than sold at a list price. Request a quote and we will confirm the configuration, the site requirements and the lead time before anything is ordered. Quote review is also where we confirm argon supply and purity, exhaust extraction over the torch or spark stand, single-phase power and breaker rating, bench load rating, and cooling water where the design requires it.
Have a question about this product?
Have a question? Just ask.
Send it over and we'll email you a personalized answer, with no call or scheduling.
Prefer to talk it through?