Protocol
Drosophila climbing assay protocol
The climbing assay scores fly locomotion by counting flies that climb past a line, or measuring how high they climb, in the seconds after a tap knocks them down.
ConductScience Editorial · Published November 21, 2026 · 10 references
What the climbing assay measures
Negative geotaxis is the innate escape response in which a fly tapped to the bottom of a vial climbs the wall, against gravity.3,4 Nearly all flies climb on their legs rather than jumping or flying. Removing the hind legs impairs climbing, while removing the wings does not.5,6
Gargano and colleagues developed the RING method, short for rapid iterative negative geotaxis, to follow how this climbing declines with age.3 With age, flies start climbing later and climb more slowly, and the slower speed accounts for most of the decline.6,5 The decline depends on genetic background, and long-lived Indy and chico mutants show it later.3
Ali and colleagues use the assay to measure locomotor deficits in fly models of neurodegeneration.1 In their example, 10-day-old flies overexpressing tau in all neurons climbed less than flies overexpressing GFP, in both sexes.1
Labs score negative geotaxis in one of three ways.6
- The percentage of flies above a line when the time limit ends.6,1
- The height flies reach in a set time, as in the RING method.6
- The time flies take to climb to a set height.6,4
All three show climbing getting worse with age.6
Set up the vials and the rack
Each group of flies climbs in its own empty vial, with a line marked at a set height.1,7 In Ali and colleagues’ version, each group needs two empty vials and tape to join them, with a line drawn around the lower vial.1
To photograph or film a trial, hold the vials upright in a rack or frame in front of a light box or white panel, with the camera square to the rack.4,8 Fidan fixed a centimeter ruler to the panel, so heights could be read straight from the recordings.8
Watanabe and Riddle glued 12.7 cm (5 inch) glass vials, closed with foam plugs, into a standard vial rack.9 They tapped the whole rack down on a solid surface, with foam tape under it to soften the repeated taps.9
Test at the same temperature and humidity in every session. Linderman and colleagues tested at room temperature, with the humidity held between 50% and 60%.4
Choose the line height and time limit
A low line, such as 5 cm, with a short time limit picks up gross locomotor deficits.8 Madabattula and colleagues raised the line to 17.5 cm and the time limit to 2 minutes, and report that the change detects milder deficits earlier.10 Fidan tested the same tubes at both heights in one session, 5 cm first and 17.5 cm straight after.8
| Protocol | Vial | Line and time limit |
|---|---|---|
| Ali and colleagues | Two 28.5 × 95 mm vials taped mouth to mouth1 | 8 cm in 10 seconds1 |
| Bartholomew and colleagues | One empty vial7 | 5 cm in 18 seconds7 |
| Fidan | Glass tube 25 cm tall and 2.5 cm across8 | 5 cm in 10 seconds, then 17.5 cm in 120 seconds8 |
| Madabattula and colleagues | Glass graduated cylinder, sealed with paraffin film10 | 17.5 cm in 2 minutes10 |
| RING method | Several vials in a rack, photographed together3,2 | Height climbed in 2 to 4 seconds2,6 |
If you expect climbing to improve, as after exercise training, a taller vial leaves room to record the gain.2
Run the assay, step by step
These steps follow Ali and colleagues’ protocol, in which each group climbs in two empty vials taped mouth to mouth.1
Move the flies to fresh food the day before
Transfer the flies to new food vials the day before the assay, to keep wet food from hindering their climbing.7
Sort the flies into groups of 10
Put 10 flies of one sex in each food vial. Keep males and females apart, because the sexes behave differently and mixed groups give data that are hard to interpret.1 For aging studies, use siblings from the same parental cross, so genetic background stays the same.1
Keep CO2 low, or avoid it
If you sort on carbon dioxide (CO2), use the lowest flow that anesthetizes the flies, keep each exposure short, and give control flies the same exposure.7 Ali and colleagues sort on CO2 and wait at least 1 hour before testing.1 To avoid CO2 on the test day, sort the flies earlier and move them into their test vials without anesthesia, as several protocols do.4,8
Load a group into a marked vial
Draw a line around an empty vial, 8 cm above its bottom.1 Tap one group in without letting any fly escape, then at once cover it with a second empty vial, mouth to mouth.1 Line the openings up exactly, so the flies have an even surface to climb, and tape the joint.1
Let the flies settle
Give the flies 1 minute to get used to the vial.1 Other protocols allow 10 minutes.4,8
Tap them down and start the clock
Tap the vial gently so all the flies drop to the bottom, and start timing at the last tap.1,8 Several protocols tap three to five times.4,8,9
Count the flies above the line
At 10 seconds, count the flies above the 8 cm line.1 If the flies move too fast to count by eye, photograph or film the vial and count them in the frame at the time limit.
Repeat with rests
Run 10 trials for each group, with 1 minute of rest between trials.1
Score the climbing
For each trial, record the flies above the line as a percentage of the group.1 Average the 10 trials into one percentage for the group.1 For each genotype or treatment, Ali and colleagues test 10 to 20 groups of 10 flies, 100 to 200 flies.1 Treat each vial as one unit in the statistics.8
Scoring photos with the RING method
In the RING method, Tinkerhess and colleagues photograph six vials at a time, usually 2 seconds after the tap, and divide each vial into four quarters of equal height.2 A fly in the top quarter scores 4, the next quarter down 3, the next 2 and the bottom quarter 1. A fly still on the vial floor scores 0.2 A vial’s climbing index is the average of its flies’ scores. Its index for the day averages the indices from four photos, each taken after its own tap.2 In Watanabe and Riddle’s study, a researcher who did not know each vial’s group counted the flies in each quarter.9
Timing each fly from video
From video, the time each fly first crosses the line can be read from the frame times.8 If a fly had not crossed when time ran out, Fidan recorded its time as the full time limit and read its height from the last frame.8
Score climbing from video
ConductVision tracks the flies’ heights in several vials at once from video, and reports the percentage that passed the line, climbing speed and height reached.
Common problems and how to fix them
- Climbing is low in every group, controls included. In Bartholomew and colleagues’ tests, flies given 5 minutes of 100% CO2 climbed 57% less than air-exposed controls an hour later, and were still impaired 24 hours later.7 On a CO2 pad, the same team found that 10 minutes at the lowest flow that anesthetized the flies, 2.4 L/minute, left climbing unchanged an hour later. Raising the flow to 3.0 and 5.0 L/minute cut climbing by 27% and 62%.7 Check the flow and the exposure time before anything else.
- Scores differ by rack position. In Watanabe and Riddle’s analysis, a vial’s position in the rack affected its climbing index.9 Record each vial’s position, move each group to a new position for its next session, and include position in the statistics. Watanabe and Riddle modeled vial position as a random effect.9
- Flies are tired from other handling. Tinkerhess and colleagues measure climbing before the day’s exercise training, to avoid effects of fatigue.2 Test climbing before any other handling that day.
- Flies barely leave the bottom. Flies with severe motor mutations can hardly climb at all. For these flies, switch to an assay that measures movement directly.1
Run-day checklist
Tick each item as you set up, or print the list for the fly room.
0 of 9 done
Related equipment, tools and data
Mazes and apparatus for other fly behavior tests.
A choice maze with one entrance and nine exits that scores how often flies go up or down.
ConductVision Drosophila Package
Video scoring for fly behavior, including climbing past a line you set, in several vials at once.
Group assignment and a balanced run order.
Negative geotaxis in published research
How many animal research papers mention negative geotaxis and climbing assays each year, and which species they used.
Questions
- What does the Drosophila climbing assay measure?
- It measures locomotor function through negative geotaxis, the escape response in which flies tapped to the bottom of a vial climb its wall.3,1
- How high should the line be, and how long should flies get?
- Published protocols count flies past 8 cm at 10 seconds, or past 5 cm at 18 seconds.1,7 To pick up milder deficits, Madabattula and colleagues raised the line to 17.5 cm and allowed 2 minutes.10
- How many flies go in each vial?
- Use groups of 10 flies of one sex.1,7,8 Photo-based studies have used groups of 20.9,4
- What is the RING assay?
- RING, short for rapid iterative negative geotaxis, scores climbing from photos of several vials taken a few seconds after the tap, which lets you test many groups at once.3,2
- Do the number of flies in a vial, the time of day or repeated testing change the results?
- In Gargano and colleagues’ RING tests, none of the three changed performance.3 Linderman and colleagues tested the same flies every day in an infection study and found no sign that the daily tests changed later climbing results.4
References
- Ali YO, Escala W, Ruan K, et al. Assaying locomotor, learning, and memory deficits in Drosophila models of neurodegeneration. Journal of Visualized Experiments. 2011. https://doi.org/10.3791/2504
- Tinkerhess MJ, Ginzberg S, Piazza N, et al. Endurance training protocol and longitudinal performance assays for Drosophila melanogaster. Journal of Visualized Experiments. 2012. https://doi.org/10.3791/3786
- Gargano JW, Martin I, Bhandari P, et al. Rapid iterative negative geotaxis (RING): a new method for assessing age-related locomotor decline in Drosophila. Experimental Gerontology. 2005. https://doi.org/10.1016/j.exger.2005.02.005
- Linderman JA, Chambers MC, Gupta AS, et al. Infection-related declines in chill coma recovery and negative geotaxis in Drosophila melanogaster. PLoS ONE. 2012. doi:10.1371/journal.pone.0041907
- Rhodenizer D, Martin I, Bhandari P, et al. Genetic and environmental factors impact age-related impairment of negative geotaxis in Drosophila by altering age-dependent climbing speed. Experimental Gerontology. 2008. doi:10.1016/j.exger.2008.04.011
- Jones MA, Grotewiel M. Drosophila as a model for age-related impairment in locomotor and other behaviors. Experimental Gerontology. 2011. doi:10.1016/j.exger.2010.08.012
- Bartholomew NR, Burdett JM, VandenBrooks JM, et al. Impaired climbing and flight behaviour in Drosophila melanogaster following carbon dioxide anaesthesia. Scientific Reports. 2015. doi:10.1038/srep15298
- Fidan M. Line-dependent differences in locomotor performance: a comparative climbing analysis in wild-type and classical mutants of Drosophila melanogaster. Fly. 2026. doi:10.1080/19336934.2026.2760604
- Watanabe LP, Riddle NC. Exercise-induced changes in climbing performance. Royal Society Open Science. 2021. doi:10.1098/rsos.211275
- Madabattula ST, Strautman JC, Bysice AM, et al. Quantitative analysis of climbing defects in a Drosophila model of neurodegenerative disorders. Journal of Visualized Experiments. 2015. doi:10.3791/52741
More protocols
Protocol
Protocol
Protocol
Protocol
Protocol
Protocol
Protocol
Protocol
Protocol
Guide
Protocol
