Protocol

Acetone test protocol for mice and rats

Touch a drop of acetone to the sole of a hind paw through the mesh floor, then count, time or rate the animal’s response as the skin cools.

ConductScience Editorial · Published November 21, 2026 · 8 references

HOLDER CAGESMESH PLATFORMACETONE
Drawing · Holder cages on a mesh platform
Stimulus
Acetone cools the skin to an innocuous 15 to 21°C as it evaporates.1
Drops
Two rat protocols give each hind paw five drops, about 2 minutes apart in one and 5 in the other.2,3
Score
The percentage of drops that evoke a withdrawal, the time spent flicking or licking, or a 0 to 3 severity score.1,3,4
Control
Water warmed to 30°C, applied the same way.1

What the acetone test measures

A drop of acetone dabbed on the sole of a hind paw evaporates and cools the skin.4 Deuis and colleagues put the cooled skin at an innocuous 15 to 21°C.1 The actual temperature depends on the room, the skin’s starting temperature and the amount of acetone applied.1 An innocuous stimulus does not normally make an animal withdraw its paw. An animal that withdraws anyway is said to have allodynia, so the test is usually read as a measure of cold allodynia.1

Choi and colleagues were among the first to describe the test, in 1994.1,5 They tied the L5 and L6 spinal nerves on one side in rats and saw signs of cold allodynia for at least 16 weeks.5 Colburn and colleagues compared normal mice with mice lacking TRPM8, an ion channel activated by cold.6 After an injury, the mice lacking it responded significantly less to acetone cooling.6

The test has been validated in several models of inflammatory and neuropathic pain, in both mice and rats.1 Because the drop goes on one paw, a model that affects one side can be compared with the other side.1 The test measures how strongly the animal responds to cooling. It does not find a cold threshold, the temperature at which a response begins.4 Brenner and colleagues note that naive mice do not respond. With no response to lose, the test is of limited use for detecting a loss of cold sensation.4

Run the test under your approved animal protocol, which sets the model, how often each animal is tested and the humane endpoints.

Set up the cages on a mesh platform

Each animal goes alone in a small cage over a mesh or barred floor.1 Use clear, open-bottomed cages on a raised mesh platform, so you can reach the hind paws from below and watch the response through the walls. Leem and colleagues kept each rat under a clear plastic dome on a metal mesh floor.3

Let each animal settle in its cage before the first drop, for the same length of time in every session. Settling keeps walking and exploring to a minimum, so they are not mistaken for a response.1 For the von Frey test, run on the same cages, Deuis and colleagues give settling times of under 15 minutes for rats and an hour or more for mice.1 For the acetone test, Brenner and colleagues let mice settle on the wire mesh for 3 hours.4

Keep the room at a steady temperature, and write it down on each test day.

What you need
ItemUse
Holder cagesClear cages that stand on the mesh, one animal in each
Mesh platformRaised and open underneath, for reaching the paws
Syringe and tubingA 1 ml syringe and a short piece of PE-10 polyethylene tubing, to form the drop2
AcetoneEnough for every drop in the session, capped between drops
Warm waterWater at 30°C for the control drops1
Timer or cameraTo time the response, or to film it for scoring in slow motion1

Apply the drop, step by step

These steps follow the rat protocols of Datta and colleagues and of Leem and colleagues, which score the percentage of drops that evoke a withdrawal.2,3 For mice, Brenner and colleagues dabbed acetone onto the sole from a 1 ml syringe and timed the response, as the next section describes.4

  1. Load the syringe

    Draw acetone into a 1 ml syringe connected to a short piece of PE-10 polyethylene tubing.2

  2. Form a drop

    Push the plunger until a drop of acetone hangs from the end of the tubing.3 Datta and colleagues used a drop of 0.1 ml for rats.2

  3. Wait until the animal is still

    Apply the drop only when the animal stands still with its hind paws on the mesh. A paw that moves while the animal walks, grooms or reacts to a tickle can be mistaken for a response.1

  4. Touch the drop to the heel

    Bring the drop up through the mesh until it touches the heel of the hind paw.3 Let only the acetone touch the skin, not the tubing.

  5. Record the response

    Count a prompt withdrawal of the paw as a response.2,3 Watch each drop for the same length of time, and write down both that time and what counts as a response.

  6. Alternate the paws

    Datta and colleagues gave 10 drops a day, five on each hind paw, switching paws each time, with about 2 minutes between one drop and the next.2 Leem and colleagues gave each paw five drops at 5-minute intervals.3

  7. Work out the score

    Divide each paw’s withdrawals by its number of drops and multiply by 100, to give the percentage of drops that evoked a withdrawal.3

Choose how to score the response

Labs use one of three methods: count withdrawals, time the flicking or licking, or rate the response from 0 to 3.1 Choose one method before the study and use it for every animal.

Three ways to score the acetone test
MethodWhat you record
Withdrawal frequencyThe percentage of drops that evoke a withdrawal, from five drops on each paw, in rats2,3
Time spent respondingSeconds spent flicking or licking the paw in the 60 seconds after the first 10, in mice4
Severity score0 for no response, 1 for a brisk withdrawal or flick, 2 for repeated flicking, 3 for repeated flicking and licking1

Brenner and colleagues leave out the first 10 seconds as a reaction to the drop landing, and time the rest with a stopwatch.4 Responses can be too quick to judge as they happen. Film them and score the video in slow motion.1

Report what the animal did, such as withdrawing, flicking or licking the paw. Deuis and colleagues note that the word pain is rarely appropriate in animal studies.1

Run a water control and score blind

Allchorne and colleagues note that the drop could evoke a withdrawal through a chemical, smell or touch stimulus, whatever its temperature.7 Water warmed to 30°C and applied the same way is the usual control.1 It matches the touch of the drop, but not the smell of acetone.

Test the animals in random order, with the person scoring blind to each animal’s group.1

Randomize the testing order

Our study randomizer assigns animals to groups at random and builds Latin square testing orders.

Open the study randomizer

Test touch sensitivity on the same setup

In the von Frey test, a thin filament pressed up against the sole until it bends delivers a set force for 2 to 5 seconds.1 Deuis and colleagues give typical forces of 0.2 to 13.7 mN for mice and 5.9 to 98 mN for rats.1 That is about 0.02 to 1.4 g for mice and 0.6 to 10 g for rats.1 A withdrawal, licking or shaking of the paw during the touch or just after it counts as a response.1

The up-down method of Chaplan and colleagues finds the 50% withdrawal threshold quickly, by stepping the force up or down around it.8 After no response, test the next stronger filament. After a response, test the next weaker one.1 Stop when you have at least four readings after the first change between response and no response.1 Chaplan and colleagues found good agreement within and between observers for the up-down method in rats with a nerve injury.8 Avoid testing while the animal grooms, which can hide a response.1

Work out the threshold

Our von Frey calculator turns your filament sequence and responses into the withdrawal threshold, with confidence intervals and methods text to copy.

Open the von Frey calculator

Common problems and what to do

  • Drops vary in size. Acetone’s surface tension is about a third of water’s, 25.2 against 72.8 mN/m, so even drops are hard to form with a pipette or syringe.1 It is also hard to apply exactly the same amount every time.4 You cannot make every drop identical, so keep the method fixed: the same syringe, tubing and technique each time. Report how you applied the acetone.
  • Healthy animals can react. Deuis and colleagues note that some naive mice and rats do respond to acetone, which makes the test less sensitive.1 The likely cause is its smell or, where labs spray it, the sound of the spray.1 Leem and colleagues tested every animal three days before the injury to set its baseline.3 Compare each animal with its own baseline.
  • Skin cooling varies from day to day. The room and the animal’s temperature change how fast the acetone evaporates, and so how far the skin cools.7 Keep the room temperature steady and record it with the scores.
  • Scores differ between people. Each researcher draws a slightly different line for what counts as a response, so results can vary between labs.1 Write down what counts as a response and report it with your results, so other labs can compare. Within a study, have one person, blind to the groups, score every animal.

Run-day checklist

Tick each item as you set up, or print the list for the testing room.

0 of 9 done

Equipment, tools and related pages

Questions

What does the acetone test measure?
How strongly an animal responds when evaporating acetone cools the sole of its hind paw.4 A strong response to this mild cooling is usually read as cold allodynia.1
How much acetone should I apply?
Datta and colleagues used a 0.1 ml drop for rats, formed on PE-10 tubing connected to a 1 ml syringe.2 Use the same amount and method for every drop, because the amount changes how far the skin cools.1
How many drops does each paw get?
In the rat protocols on this page, each hind paw gets five drops, and the score is the percentage that evoke a withdrawal.2,3 Give every animal the same number of drops.
Should I spray the acetone or apply a drop?
Apply a drop, as the protocols on this page do. Some labs spray instead, because even drops are hard to form.1 But the sound of a spray, like the smell of acetone, may make naive animals respond, which makes the test less sensitive.1
Is a withdrawal from acetone a sign of pain?
It is a pain-like behavior. Pain cannot be measured directly in animals, so it is inferred from behaviors such as withdrawal.1 Report the behavior you scored, such as withdrawal, flicking or licking.
Can I run the von Frey test on the same setup?
Yes. The von Frey test also puts each animal alone in a small cage on a mesh floor, so the same cages and platform serve both tests.1

References

  1. Deuis JR, Dvorakova LS, Vetter I. Methods used to evaluate pain behaviors in rodents. Frontiers in Molecular Neuroscience. 2017. doi:10.3389/fnmol.2017.00284
  2. Datta S, Chatterjee K, Kline RH 4th, et al. Behavioral and anatomical characterization of the bilateral sciatic nerve chronic constriction (bCCI) injury: correlation of anatomic changes and responses to cold stimuli. Molecular Pain. 2010. doi:10.1186/1744-8069-6-7
  3. Leem YJ, Joh JW, Joeng KW, et al. Central pain from excitotoxic spinal cord injury induced by intraspinal NMDA injection: a pilot study. The Korean Journal of Pain. 2010. doi:10.3344/kjp.2010.23.2.109
  4. Brenner DS, Golden JP, Gereau RW 4th. A novel behavioral assay for measuring cold sensation in mice. PLoS One. 2012. doi:10.1371/journal.pone.0039765
  5. Choi Y, Yoon YW, Na HS, et al. Behavioral signs of ongoing pain and cold allodynia in a rat model of neuropathic pain. Pain. 1994. doi:10.1016/0304-3959(94)90023-X
  6. Colburn RW, Lubin ML, Stone DJ Jr, et al. Attenuated cold sensitivity in TRPM8 null mice. Neuron. 2007. doi:10.1016/j.neuron.2007.04.017
  7. Allchorne AJ, Broom DC, Woolf CJ. Detection of cold pain, cold allodynia and cold hyperalgesia in freely behaving rats. Molecular Pain. 2005. doi:10.1186/1744-8069-1-36
  8. Chaplan SR, Bach FW, Pogrel JW, et al. Quantitative assessment of tactile allodynia in the rat paw. Journal of Neuroscience Methods. 1994. doi:10.1016/0165-0270(94)90144-9