Research data · Measure

Startle amplitude

Startle amplitude is the size of an animal's whole-body flinch to a sudden loud sound, recorded by a motion sensor under its enclosure.

Fear makes the startle larger, and it grows smaller when the same sound repeats, which is habituation.1

769 papers from 2021 to 2025 mention prepulse inhibition and acoustic startle
51 of them name startle amplitude

How it is measured

The acoustic startle response is a protective response to a sudden, intense sound.1

The sensor turns the movement into a signal, and software takes its peak or its average over a short window after the sound.

A softer sound just before the pulse also makes the startle smaller, which is prepulse inhibition.1

Papers that name startle amplitude, by test

We count a paper when its title or abstract names the measure. Many papers name their measures only in the full text, so each count is a minimum. The chart counts the test's papers from 2021 to 2025.

Papers that name startle amplitude, year by year

Show

The chart shows papers each year.

Prepulse inhibition and acoustic startle

Startle amplitude

51 papers, 6.6% of the test's 769 papers

  • 2021: 14 papers
  • 2022: 13 papers
  • 2023: 9 papers
  • 2024: 9 papers
  • 2025: 6 papers
Show the percents as a table
Percent of each test's papers that name startle amplitude, by year
TestMeasure20212022202320242025
Prepulse inhibition and acoustic startleStartle amplitude7.7%7.7%5.8%6.6%4.8%
Papers from 2021 to 2025 that name startle amplitude, by test and year
TestMeasurePapers20212022202320242025
Prepulse inhibition and acoustic startleStartle amplitude511413996

Startle amplitude by mouse strain

Each table shows one measure from one Mouse Phenome Database (MPD) project, for one sex. Compare strains within a table, because the same strain's values can differ from project to project.

All of these tables come from prepulse inhibition and acoustic startle tests, from one MPD project, Willott1 (2002).

Startle amplitude

Willott1 (2002): 40 strains, female mice, 5 to 6 weeks old. The chart opens on the 11 common inbred strains. MPD measure 9102: "acoustic startle response (ASR), evoked by 70 dB sound pressure level".
Dots are strain means, highest first, with lines 1 SD either side. Lines are cut off at 0.
  • Common inbred strains

Hover over or tap a strain to see its values, or use Tab and the arrow keys.

Common inbred strains come first, in bold, then the rest; each group runs A to Z.

StrainMiceMeanSDRange across mice
129S1/SvImJ1011245.569.8 to 198
A/J1062.816.634.0 to 82.7
AKR/J1072.818.352.1 to 97.7
BALB/cJ1813144.372.8 to 218
C3H/HeJ1060.521.818.6 to 92.8
C57BL/6J1192.154.10 to 168
CBA/J986.425.157.6 to 128
DBA/2J1089.862.746.4 to 254
FVB/NJ1081.326.244.5 to 119
NOD/ShiLtJ1090.329.351.3 to 136
SJL/J1069.918.047.1 to 104

Source: Willott JF, Johnson KR (2002). Startle and prepulse inhibition survey of 40 inbred strains of mice. Mouse Phenome Database (RRID:SCR_003212), project Willott1, measure 9102, data accessed 20 Nov 2026, https://phenome.jax.org/projects/Willott1. Paper: PMID 12931957.

Download all of this section's tables, each with its source, as one CSV file. The CSV is part of "Behavioral tests in published research", a free data set. Add it to your free ConductScience account to download it.

Add to my account

How startle amplitude ranks among the measures of prepulse inhibition and acoustic startle

Each bar counts the test's papers from 2021 to 2025 that name a measure. One paper can name several measures.

Measures named in papers that mention prepulse inhibition and acoustic startle

Papers from 2021 to 2025, and their percent of the test's 769 papers

246 papers 32.0%
Startle amplitude (this page)
51 papers 6.6%
Startle habituation
15 papers 2.0%

Equipment for prepulse inhibition and acoustic startle

Our store sells one product for this test.

Sources

  1. Habituation and prepulse inhibition of acoustic startle in rodents

    Valsamis B, Schmid S. Journal of Visualized Experiments, 2011.

Mouse strain values: Mouse Phenome Database (MPD), RRID:SCR_003212, and the MPD projects named under each table.

More on startle amplitude

How we counted

A paper counts toward a measure when its title or abstract names it.

The full method, with each source and its terms of use, is on the page Behavioral tests in published research.

The mouse strain values come from the Mouse Phenome Database (MPD). Each table holds what one MPD project measured in one sex. A strain with fewer than 5 mice is left out, because so few mice give an unsteady mean. Where MPD has no mouse-by-mouse data, the SD is worked out from the standard error that MPD posts. The common inbred strains come first in each table: 129S1/SvImJ, A/J, AKR/J, BALB/cByJ, BALB/cJ, C3H/HeJ, C57BL/6J, CBA/J, DBA/2J, FVB/NJ, NOD/ShiLtJ and SJL/J. They are the classical inbred strains that appear in at least 40 of the 130 MPD behavior projects with strain means, plus BALB/cJ, which appears in 30.

How to cite

APA

ConductScience. (2026, November 22). Startle amplitude [Data set]. https://conductscience.com/data/measures/startle-amplitude

BibTeX

@misc{conductscience_measure_startle_amplitude_2026,
  author = {{ConductScience}},
  title = {Startle amplitude},
  year = {2026},
  month = nov,
  url = {https://conductscience.com/data/measures/startle-amplitude},
  note = {Data set, released November 22, 2026},
}

For a strain value, cite the MPD project named under its table.