Medicine Stability Test Chamber(BJPX-MS)
Precision environmental chamber for pharmaceutical stability testing and research applications with independent temperature, humidity, and illumination control.
| Automation Level | semi-automated |
| BJPX-MS300 | BJPX-MS400 |
| Sterilization Type(Optional) | UV sterilization |
| 290L | 402L |
| Temp. Range | 0~65℃ |
| Temp. Fluctuation | ±0.5℃ |
The Medicine Stability Test Chamber (BJPX-MS) is a precision environmental chamber designed for pharmaceutical stability studies, photostability testing, and controlled environmental research applications. This chamber provides independent control of temperature (0-65°C), humidity (40-95% RH), and illumination (up to 6000 Lux) with high accuracy and stability specifications required for ICH stability protocols and research investigations.
The system features a CFC-free R134a refrigeration system with precise temperature control (±0.5°C fluctuation) and humidity regulation (±3% RH fluctuation). The integrated single-side illumination system provides adjustable light exposure from five intensity levels, supporting photostability studies and circadian rhythm research. A 30-step programmable timer allows complex environmental cycling protocols for extended stability assessments.
How It Works
The stability chamber operates through independent environmental control systems that maintain precise temperature, humidity, and illumination conditions. Temperature regulation is achieved via a CFC-free R134a refrigeration system combined with heating elements, providing uniform temperature distribution throughout the 248L chamber volume. A PID control algorithm maintains temperature within ±0.5°C of the setpoint with 0.1°C display resolution.
Humidity control utilizes an integrated humidification/dehumidification system that maintains relative humidity between 40-95% RH with ±3% RH stability. The single-side illumination system employs adjustable light sources providing up to 6000 Lux intensity across five selectable levels, enabling photostability testing protocols. The LCD display interface allows programming of complex environmental profiles using up to 30 sequential steps, with individual step durations up to 99 hours.
Features & Benefits
Automation Level
- semi-automated
BJPX-MS300
- BJPX-MS400
Sterilization Type(Optional)
- UV sterilization
290L
- 402L
Temp. Range
- 0~65℃
Temp. Fluctuation
- ±0.5℃
Temp. Precision
- 0.1℃
Humidity Range
- 40~95%RH
Humidity Fluctuation
- ±3%RH
Illumination
- Single-side illumination 6000Lux, 5-level adjustable
Refrigeration System
- R134a refrigerant, CFC-free
Timing Range
- The timer can be set for a maximum of 99 hours for a single step, with a total of 30 steps available
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Environmental Monitoring
- Food Science
- Materials Science
- Pharmaceutical QC
Capacity
- 248L
Display Type
- LCD screen
Power/Voltage
- AC220V, 50/60Hz(Standard); 110V, 50/60Hz(Optional) (External transformer)
Weight
- 160.0 kg
Dimensions
- L: 117.8 mm
- W: 47.0 mm
- H: 44.9 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Temperature Range | 0-65°C with ±0.5°C fluctuation | Entry-level models often provide narrower ranges or less precise control | Wide range enables both refrigerated storage and accelerated aging protocols in one unit |
| Humidity Control | 40-95% RH with ±3% RH stability | Basic models may offer limited humidity ranges or higher fluctuation | Broad humidity range supports diverse stability protocols and ICH requirements |
| Illumination System | Single-side 6000 Lux with 5-level adjustment | Many chambers lack integrated illumination or offer fixed intensity | Enables photostability testing without requiring separate light chambers |
| Programming Capability | 30 steps with 99-hour step duration | Basic controllers often limited to simple setpoint operation | Complex environmental cycling protocols for comprehensive stability assessment |
| Chamber Capacity | 248L internal volume | Varies by model from benchtop to walk-in configurations | Accommodates substantial sample loads while maintaining laboratory footprint |
| Refrigeration System | CFC-free R134a refrigerant | Varies by manufacturer and age of design | Environmentally compliant with reliable cooling performance |
The BJPX-MS integrates temperature, humidity, and illumination control with advanced programming capabilities in a mid-range capacity chamber. The CFC-free refrigeration system and precise control specifications support both routine stability testing and specialized research applications.
Practical Tips
Verify temperature and humidity accuracy quarterly using NIST-traceable reference instruments at multiple setpoints.
Why: Maintains measurement traceability required for regulatory submissions and quality assurance.
Clean chamber interior monthly with appropriate disinfectants and inspect door seals for proper closure.
Why: Prevents contamination and maintains environmental integrity during extended test periods.
Allow chamber to stabilize for at least 30 minutes after loading samples before initiating protocols.
Why: Ensures uniform environmental conditions are established throughout the chamber volume.
Position samples to allow adequate air circulation and avoid blocking chamber ventilation pathways.
Why: Prevents thermal gradients and ensures uniform environmental exposure to all specimens.
Document chamber loading patterns and sample positions for each study protocol.
Why: Enables correlation of environmental exposure with sample position for data interpretation.
If humidity control becomes unstable, check for water reservoir levels and clean humidity sensors.
Why: Humidity system requires periodic maintenance to maintain specified performance levels.
Ensure adequate ventilation clearance around chamber and avoid blocking air intake/exhaust ports.
Why: Proper ventilation prevents overheating and maintains optimal refrigeration system performance.
Setup Guide
What’s in the Box
- Medicine Stability Test Chamber main unit
- Power cord
- User manual and documentation
- Sample shelving system (typical)
- Temperature/humidity calibration certificate (typical)
- Optional UV sterilization system (if specified)
Warranty
ConductScience provides a standard one-year manufacturer warranty covering parts and labor, with technical support available for installation guidance and operational assistance.
Compliance
What is the temperature uniformity throughout the chamber volume?
The system maintains ±0.5°C temperature fluctuation with 0.1°C precision. Consult product datasheet for specific spatial uniformity specifications across the 248L volume.
Can this chamber perform light/dark cycling for circadian studies?
Yes, the 5-level adjustable illumination system (up to 6000 Lux) combined with 30-step programming allows custom light/dark cycles with precise timing control.
What sample capacity can the chamber accommodate?
The 248L internal volume can accommodate multiple sample sets depending on specimen size. Consult product datasheet for specific shelving configurations and load capacity.
How accurate is the humidity control at different temperature setpoints?
The system maintains ±3% RH humidity stability across the 40-95% RH range. Performance may vary with temperature setpoint - consult product datasheet for complete performance maps.
What calibration requirements are needed for validation?
Regular calibration of temperature and humidity sensors is recommended using NIST-traceable standards. Consult product datasheet for recommended calibration intervals and procedures.
Can the chamber be networked for remote monitoring?
The standard configuration includes LCD display interface. Consult product datasheet for available networking or data logging options.
What power requirements are needed for installation?
Standard configuration requires AC220V, 50/60Hz power supply. Optional 110V operation available with external transformer. Consult product datasheet for power consumption specifications.
Have a question about this product?
Accessories
Enhance your setup with compatible accessories