Precision temperature-controlled incubator for BOD testing and environmental applications, featuring dual heating/cooling with 0.1°C resolution and automatic defrost control.
| Automation Level | semi-automated |
| BJPX-B150P | BJPX-B250P |
| Function | Temp. Range |
| Temp. Resolution Ratio | 0.1℃ |
| Temp. Motion | High Temp:±0.5℃ Low Temp:±1℃ |
| Temp. Uniformity | ±1.5℃ |
The Multi-program BOD Incubator is a precision temperature-controlled environmental chamber designed for biochemical oxygen demand (BOD) testing and other temperature-sensitive laboratory applications. This unit features dual heating and cooling capabilities with stainless steel heating elements and an air-cooled hermetic compressor system using R134a refrigerant. The incubator maintains precise temperature control with 0.1°C resolution and automatic intelligent defrosting functionality.
The chamber construction employs cold-rolled steel with electrostatic spray exterior finish and polyurethane insulation for thermal stability. The system provides temperature uniformity within ±1.5°C throughout the chamber volume, making it suitable for applications requiring consistent environmental conditions over extended incubation periods. Power ratings range from 0.8kW to 1.2kW depending on configuration.
How It Works
The Multi-program BOD Incubator operates through a dual heating and cooling system that maintains precise temperature control across a wide range. Stainless steel heating elements provide controlled heat input, while an air-cooled hermetic compressor system with R134a refrigerant enables cooling capabilities. The system continuously monitors chamber temperature with 0.1°C resolution and adjusts heating or cooling output to maintain setpoint conditions.
Temperature uniformity is achieved through the insulated chamber design using polyurethane insulation and controlled air circulation. The automatic intelligent defrosting system prevents ice buildup on cooling elements that could compromise temperature stability. The cold-rolled steel construction with electrostatic spray finish provides durability while the inner chamber design ensures consistent environmental conditions throughout the working volume.
Features & Benefits
Automation Level
- semi-automated
BJPX-B150P
- BJPX-B250P
Function
- Temp. Range
Temp. Resolution Ratio
- 0.1℃
Temp. Motion
- High Temp:±0.5℃ Low Temp:±1℃
Temp. Uniformity
- ±1.5℃
Structure
- nner Chamber
Outer Shell
- Cold rolling steel electrostatic spraying exterior
Insulation Layer
- Polyurethane
Heater
- Stainless steel heater
Power Rating
- 0.8kW
1.0kW
- 1.2kW
Compressor
- Air cooled hermetic compressor
Cryogen
- R134a
Defrost Structure
- Automatic control intelligent defrosting
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Environmental Monitoring
- Food Science
- Industrial Hygiene
- Microbiology
- Pharmaceutical QC
Weight
- 29.98 kg
Dimensions
- L: 42.0 mm
- W: 43.6 mm
- H: 38.0 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Temperature Control Resolution | 0.1°C resolution with automatic control | Basic models often provide 1°C resolution | Enables precise environmental control for temperature-sensitive biochemical assays. |
| Heating and Cooling Capability | Dual system with stainless steel heaters and R134a compressor | Entry-level units typically offer heating only | Provides full temperature range control for diverse incubation requirements. |
| Defrost System | Automatic intelligent defrosting control | Manual defrost or no cooling capability | Maintains consistent performance without user intervention during extended operations. |
| Insulation Design | Polyurethane insulation with cold-rolled steel construction | Basic insulation in standard laboratory incubators | Ensures thermal stability and energy efficiency during long-term studies. |
| Temperature Uniformity | ±1.5°C uniformity throughout chamber | Standard incubators may have wider temperature variations | Provides consistent conditions across all sample positions for reproducible results. |
This Multi-program BOD Incubator offers precision temperature control with dual heating and cooling capabilities, automatic defrost functionality, and superior temperature uniformity compared to basic laboratory incubators. The robust construction and intelligent control systems make it suitable for demanding environmental testing and biochemical applications.
Practical Tips
Verify temperature accuracy quarterly using a certified reference thermometer at multiple points within the chamber.
Why: Ensures measurement accuracy for regulatory compliance and data integrity.
Clean air circulation vents monthly to prevent dust buildup that could affect temperature uniformity.
Why: Maintains optimal air flow patterns essential for consistent chamber conditions.
Allow samples to reach room temperature before loading to minimize initial temperature fluctuations.
Why: Reduces recovery time and prevents temporary temperature excursions that could affect results.
If temperature uniformity appears compromised, check for overloading and ensure adequate spacing between containers.
Why: Proper air circulation is critical for maintaining specified temperature uniformity throughout the chamber.
Record both set temperature and actual chamber temperature for each experimental run.
Why: Provides documentation of actual incubation conditions for experimental reproducibility and troubleshooting.
Ensure adequate ventilation around the unit and never block air intake or exhaust vents.
Why: Prevents overheating of compressor components and maintains safe operating conditions.
Setup Guide
What’s in the Box
- Multi-program BOD Incubator main unit
- Power cord
- User manual and operating instructions
- Temperature calibration certificate (typical)
- Internal shelving system (typical)
- Spare fuses (typical)
Warranty
ConductScience provides a standard one-year manufacturer warranty covering parts and labor, with technical support available for installation guidance and troubleshooting assistance.
Compliance
What is the temperature range and accuracy specification for BOD testing?
The incubator provides 0.1°C temperature resolution with stability of ±0.5°C at high temperatures and ±1°C at low temperatures, with ±1.5°C uniformity throughout the chamber. Consult product datasheet for complete temperature range specifications.
How does the defrost system affect temperature stability during operation?
The automatic intelligent defrosting system operates without manual intervention and is designed to minimize temperature fluctuations during defrost cycles, maintaining consistent incubation conditions.
What power requirements are needed for installation?
Power ratings range from 0.8kW to 1.2kW depending on unit configuration. Verify specific electrical requirements with your unit model before installation.
How should the chamber be cleaned between different sample types?
Clean the inner chamber with appropriate laboratory disinfectant suitable for your application, ensuring complete drying before loading new samples to prevent contamination.
What refrigerant system is used and what are the environmental considerations?
The unit uses R134a refrigerant with an air-cooled hermetic compressor system, eliminating the need for water connections while providing reliable cooling performance.
How long does temperature equilibration take after setpoint changes?
Allow minimum 30 minutes for temperature equilibration after setpoint changes, with longer times needed for larger temperature differentials or when chamber is loaded with samples.
What maintenance is required for the heating and cooling systems?
Regular cleaning of air vents and periodic calibration verification are recommended. Consult user manual for specific maintenance schedules for heating elements and compressor components.