| Automation Level | manual |
| PDR-35 | Brix(%) |
| 0~35% | 0.1 |
| ±0.2 | 0°C~40°C(32℉~104℉) |
| ±0.5°C(1°F) | 2xAAA(1.5V) |
| 165*95*60 | 0.35 |
The Portable Digital Refractometers PDR-F Series provides precise refractive index and Brix measurements for laboratory and field applications. These handheld instruments feature digital displays with temperature compensation and multiple measurement scales optimized for different concentration ranges. The series includes models covering Brix ranges from 0-35% up to 58-92%, with refractive index measurements from 1.3330 to 1.3900.
Each unit operates on standard AAA batteries and includes automatic temperature compensation across the 0°C to 40°C range. The compact 165×95×60 mm design enables portable measurements while maintaining laboratory-grade accuracy of ±0.2% for Brix and ±0.0003 for refractive index measurements. Digital readouts eliminate subjective interpretation of analog scales, providing consistent results across multiple operators.
How It Works
Digital refractometers measure the refractive index of samples by determining the critical angle at which total internal reflection occurs at the sample-prism interface. When light passes from a denser medium (the prism) into a less dense medium (the sample), the angle of refraction depends on the refractive indices of both materials. At the critical angle, light undergoes total internal reflection, creating a sharp boundary between light and dark regions.
The instrument's optical system directs light through the sample and detects the position of this boundary using photodetectors. Digital processing converts the boundary position into refractive index values and applies temperature compensation algorithms to account for thermal effects on the measurement. For Brix measurements, the refractive index is converted using established correlations between sucrose concentration and refractive index.
Automatic temperature compensation corrects measurements to a standard reference temperature, typically 20°C, eliminating the need for manual temperature corrections. This ensures consistent results regardless of ambient temperature variations within the instrument's operating range.
Features & Benefits
Automation Level
- manual
PDR-35
- Brix(%)
0~35%
- 0.1
±0.2
- 0°C~40°C(32℉~104℉)
±0.5°C(1°F)
- 2xAAA(1.5V)
165*95*60
- 0.35
Refractiv Index
- 1.3330~1.3900
0.0001
- ±0.0003
PDR-45
- Brix(%)
0~45%
- 0.1
PDR-85
- Brix(%)
0~85%
- 0.1
PDR-92
- Brix(%)
58~92%
- 0.1
PDR- HN1
- Brix(%)
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Environmental Monitoring
- Food Science
- Industrial Hygiene
- Materials Science
- Pharmaceutical QC
Weight
- 0.77 kg
Dimensions
- L: 6.5 mm
- W: 3.74 mm
- H: 2.36 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Measurement Range Options | Five models covering 0-35% to 58-92% Brix with refractive index 1.3330-1.3900 | Basic models often offer single fixed ranges | Allows researchers to select optimal range for their specific applications without compromising resolution. |
| Temperature Compensation | Automatic compensation across 0°C to 40°C with ±0.5°C accuracy | Manual temperature correction or limited compensation ranges | Eliminates calculation errors and ensures consistent results across varying laboratory conditions. |
| Digital Display Resolution | 0.1% Brix and 0.0001 refractive index resolution | Analog scales with limited reading precision | Provides quantitative precision required for analytical documentation and quality control protocols. |
| Accuracy Specifications | ±0.2% Brix and ±0.0003 refractive index accuracy | Entry-level instruments often have lower accuracy specifications | Meets precision requirements for quantitative analytical applications and regulatory compliance documentation. |
| Power Requirements | Standard AAA batteries for portable operation | Some models require proprietary batteries or AC power | Enables field measurements and reduces long-term operating costs through standard battery availability. |
The PDR-F Series combines laboratory-grade accuracy with portable digital operation across multiple measurement ranges. The automatic temperature compensation and digital display eliminate common sources of measurement error while maintaining the convenience of handheld operation.
Practical Tips
Calibrate with distilled water at the beginning of each measurement session and verify zero point stability.
Why: Temperature and environmental changes can cause drift in the optical system baseline.
Store the instrument in its protective case with the prism surface clean and dry.
Why: Prevents contamination and physical damage to the critical optical interface.
Allow samples to reach room temperature before measurement to maximize temperature compensation accuracy.
Why: Extreme sample temperatures can exceed the compensation range and introduce measurement errors.
Take triplicate measurements and report the average for critical quantitative work.
Why: Reduces random measurement errors and provides statistical confidence in results.
If readings appear unstable, check for air bubbles in the sample or incomplete prism coverage.
Why: Optical discontinuities create measurement artifacts that compromise accuracy.
Clean the prism with appropriate solvents for your sample type and ensure complete removal before the next measurement.
Why: Prevents cross-contamination and chemical compatibility issues with subsequent samples.
Record ambient temperature along with measurements for samples near the compensation limits.
Why: Provides additional documentation for measurement traceability and quality assurance protocols.
Setup Guide
What’s in the Box
- Digital refractometer main unit
- Calibration screwdriver (typical)
- Plastic dropper bottle (typical)
- Lint-free cleaning cloths (typical)
- User manual and calibration instructions
- Protective carrying case (typical)
Warranty
ConductScience provides a standard one-year manufacturer warranty covering defects in materials and workmanship. Technical support includes calibration guidance and troubleshooting assistance for optimal measurement performance.
Compliance
What is the minimum sample volume required for accurate measurements?
Typically 2-3 drops are sufficient to cover the prism surface completely. Ensure the sample covers the entire prism area without air bubbles for optimal accuracy.
How often should the instrument be calibrated?
Calibrate with distilled water before each measurement session or when changing sample types. Daily calibration is recommended for critical quantitative work.
Can the refractometer measure samples containing particles or turbidity?
Particulates and turbidity can interfere with optical measurements. Filter or clarify samples before measurement, or consult product datasheet for specific turbidity limits.
What is the temperature equilibration time for samples?
Allow 30 seconds for temperature equilibration between the sample and prism before taking measurements to ensure accurate temperature compensation.
How do I select the appropriate model for my concentration range?
Choose based on your expected sample range: PDR-35 for 0-35% Brix, PDR-45 for 0-45%, PDR-85 for 0-85%, or PDR-92 for high-concentration samples 58-92% Brix.
What maintenance is required for the prism surface?
Clean the prism with distilled water and dry with lint-free tissue after each use. Avoid abrasive materials that could scratch the optical surface.
Can measurements be logged or exported for data analysis?
Consult product datasheet for data logging capabilities. Manual recording of digital readings is always available for laboratory documentation.
What factors can affect measurement accuracy?
Temperature variations outside the compensation range, prism contamination, air bubbles in samples, and insufficient sample volume can impact accuracy.