W09-02R Independent Syringe Pump
High-precision independent syringe pump with 0.3125μm stroke resolution and multiple operating modes for laboratory fluid handling. Features RS485 communication, power-off memory, and supports flow rates from 924 pl/min to 136.235 ml/min.
| Stroke Resolution | 0.3125 µm |
| Speed Range | 5 µm/min – 200 mm/min |
| Control Accuracy | ≤±0.35% (10% F.S.) |
| Repeatability | ≤±0.03% F.S. |
| Min Flow Rate | 924 pL/min (10 µL syringe) |
| Max Flow Rate | 136.235 mL/min (60 mL syringe) |
Overview
The W09-02R Independent Syringe Pump delivers exceptional precision and versatility for laboratory fluid handling applications. With a maximum stroke of 105mm and stroke resolution of 0.3125μm, this pump provides ultra-precise dispensing capabilities from picoliter to milliliter volumes. The system supports linear speeds from 5μm/min to 200mm/min, making it suitable for both slow, controlled infusions and rapid dispensing protocols.
Key Features
Advanced microprocessor control ensures outstanding accuracy with control precision ≤±0.35% and repeatability precision ≤0.03% F'S. The pump operates in multiple modes including infusion, withdrawal, infusion-withdrawal, withdrawal-infusion, and continuous operations. RS485 communication interface with Modbus-RTU protocol enables seamless integration into automated laboratory systems. The unit supports up to 32 device addresses and features power-off memory retention for uninterrupted workflow continuity.
Applications
Ideal for microfluidics research, drug discovery, cell culture perfusion, analytical chemistry sample preparation, and automated liquid handling systems. The pump's precise flow control makes it essential for applications requiring accurate reagent delivery, sample dilution, or continuous perfusion in biological assays.
Stroke Resolution
- 0.3125 µm
Speed Range
- 5 µm/min – 200 mm/min
Control Accuracy
- ≤±0.35% (10% F.S.)
Repeatability
- ≤±0.03% F.S.
Min Flow Rate
- 924 pL/min (10 µL syringe)
Max Flow Rate
- 136.235 mL/min (60 mL syringe)
Max Linear Force
- 90 N
Max Stroke
- 105 mm
Operating Modes
- Infusion, Withdrawal, Infuse→Withdraw, Withdraw→Infuse, Continuous Infusion, Continuous Withdrawal, Continuous
Communication
- RS485 (Modbus-RTU)
Max Network Addresses
- 32
Signal Output
- Start/Stop, Direction, Jam Alert
Compatible Syringes
- 10 µL – 60 mL (16 standard sizes + 2 custom)
Power Memory
- Yes
Power Supply
- DC 24V (≤10W)
Dimensions
- 259 × 99.4 × 133 mm
Weight
- 2.35 kg
Protection Rating
- IP31
Operating Temperature
- 0 – 40°C
Humidity
- <85% RH (non-condensing)
Weight
- 29.98 kg
Dimensions
- L: 30.0 mm
- W: 20.0 mm
- H: 15.0 mm
Specifications
| Specification | Value |
|---|---|
| Model | W09-02R |
| Maximum Stroke | 105mm |
| Stroke Resolution | 0.3125μm |
| Linear Speed Range | 5μm/min - 200mm/min |
| Control Precision | Error ≤±0.35% (10%F'S) |
| Repeatability Precision | Error ≤0.03%F'S |
| Minimum Flow Rate | 924 pl/min (10.0μl syringe) |
| Maximum Flow Rate | 136.235 ml/min (60ml syringe) |
| Maximum Linear Force | 90N |
| Operating Modes | Infusion, Withdrawal, Infusion-Withdrawal, Withdrawal-Infusion, Continuous Infusion, Continuous Withdrawal, Continuous Mode |
| Signal Output | Start/Stop/Block |
| Communication Interface | RS485 |
| Protocol | Modbus-RTU |
| Maximum Addresses | 32 |
| Quick Connect | Yes |
| Power-off Memory | Yes |
| Standard Syringe | 10μl |
| Custom Syringes | Supports 2 custom syringes |
| Housing | Aluminum/Stainless Steel |
| Power Supply | DC24V (≤10W) |
| Dimensions (L×W×H) | 259mm × 99.4mm × 133mm |
| Weight | 2.35kg |
| Operating Temperature | 0-40°C |
| Relative Humidity | <85%RH, Non-condensing |
| Protection Rating | IP31 |
Frequently Asked Questions
What syringe sizes are compatible with this pump?
The pump includes a standard 10μl syringe and supports 2 custom syringe configurations. It can accommodate syringes ranging from 10μl to 60ml based on the flow rate specifications.
Can multiple pumps be connected for synchronized operation?
Yes, the RS485 communication interface with Modbus-RTU protocol allows up to 32 devices to be addressed and controlled simultaneously through a single communication network.
What is the minimum achievable flow rate?
The minimum flow rate is 924 pl/min (picoliters per minute) when using a 10μl syringe, making it suitable for ultra-low volume applications and microfluidics research.
No Q&A yet. Have a question? Ask below.