Intelligent Induction Sterilizer
Touchless induction sterilizer with 1-12cm detection range and 100ml reservoir for automated surface disinfectant dispensing in laboratory environments.
| Automation Level | semi-automated |
| Shell Material | ABS+PC+PP |
| Induction Distance | 1~12cm |
| Water Tank Capacity | 100ml |
| Spray Capacity | 40~60ml/h |
| Battery Capacity | 1200mAh |
The Intelligent Induction Sterilizer is a touchless spray sterilization device designed for laboratory surface decontamination. The unit employs infrared induction technology to trigger automated alcohol or disinfectant spray dispensing when hands or objects are positioned within the 1-12cm detection range. With a 100ml reservoir capacity and adjustable spray output of 40-60ml/h, the device provides consistent surface sanitization without manual contact.
The sterilizer operates on USB-C power with a 1200mAh rechargeable battery for portable use. The ABS+PC+PP shell construction provides chemical resistance suitable for laboratory disinfectants. Compact dimensions of 102×87×67mm and 196g weight enable bench-top placement or integration into laboratory workflows requiring frequent surface decontamination.
How It Works
The sterilizer utilizes infrared proximity sensing to detect objects within the 1-12cm activation range. When the sensor detects motion or presence, it triggers the internal pump mechanism to dispense a controlled volume of disinfectant through the spray nozzle. The detection system operates continuously when powered, requiring no manual activation.
The internal reservoir holds 100ml of liquid disinfectant, which is pressurized and atomized through the spray mechanism. Flow rate is electronically controlled between 40-60ml/h depending on usage patterns and proximity detection frequency. The 1200mAh battery provides extended operation between charging cycles, with Type-C USB charging compatibility for convenient power management.
Features & Benefits
Automation Level
- semi-automated
Shell Material
- ABS+PC+PP
Induction Distance
- 1~12cm
Water Tank Capacity
- 100ml
Spray Capacity
- 40~60ml/h
Battery Capacity
- 1200mAh
Input Current
- 1A
Interface Type
- Type-C
Consumption
- 2W
External Size(W*D*H)
- 102*87*67mm
Package Size(W*D*H)
- 110*95*75mm
Brand
- ConductScience
Research Domain
- Cell Biology
- Clinical Diagnostics
- Environmental Monitoring
- Food Science
- Microbiology
- Pharmaceutical QC
Power/Voltage
- 5V
Weight
- 0.26kg
Model
- U6
Net Weight
- 0.196 kg
Gross Weight
- 0.26 kg
Weight
- 0.2 kg
Dimensions
- L: 6.7 mm
- W: 10.2 mm
- H: 8.7 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Detection Range | 1-12cm infrared sensing | Manual activation or fixed proximity sensors with limited range adjustment | Flexible activation distance prevents false triggers while ensuring reliable operation across different user heights and hand positions |
| Reservoir Capacity | 100ml internal tank | Entry-level models often provide 50-75ml capacity | Extended operation between refills reduces maintenance frequency in busy laboratory environments |
| Power System | 1200mAh battery with Type-C charging | Corded operation or smaller battery capacities | Cordless operation enables flexible placement while universal charging reduces cable management requirements |
| Flow Control | 40-60ml/h controlled spray rate | Fixed output volumes or manual pump mechanisms | Consistent dispensing prevents waste while ensuring adequate disinfectant coverage for surface sterilization |
| Shell Material | ABS+PC+PP chemical-resistant construction | Basic plastic housings with limited chemical compatibility | Enhanced durability when exposed to laboratory disinfectants and cleaning agents extends operational lifespan |
This sterilizer combines infrared activation technology with controlled spray dispensing and rechargeable battery operation. The 100ml capacity and chemical-resistant construction provide practical advantages for sustained laboratory use while maintaining compact dimensions suitable for benchtop placement.
Practical Tips
Test the detection range at installation by positioning hands at various distances to verify the 1-12cm activation zone.
Why: Proper detection range ensures reliable activation without false triggers from ambient movement.
Clean the spray nozzle weekly with distilled water to prevent disinfectant residue buildup that can cause clogging.
Why: Regular cleaning maintains consistent spray patterns and prevents operational failures during critical laboratory procedures.
Position the unit at elbow height to optimize the detection angle for natural hand positioning during laboratory work.
Why: Proper positioning ensures comfortable activation without requiring awkward hand placement that could disrupt laboratory workflow.
Refill the reservoir when approximately 20ml remains to prevent air bubbles in the spray system.
Why: Maintaining adequate fluid levels ensures consistent spray output and prevents pump damage from dry operation.
Only use EPA-approved disinfectants compatible with the ABS+PC+PP shell materials to prevent housing degradation.
Why: Chemical compatibility prevents shell cracking or discoloration that could compromise device integrity and appearance.
Monitor spray pattern consistency by observing droplet distribution on test surfaces during routine operation.
Why: Consistent spray patterns indicate proper nozzle function and ensure effective surface coverage for decontamination procedures.
If activation becomes inconsistent, clean the infrared sensor window with lens cleaning solution to remove accumulated residue.
Why: Clear sensor optics maintain accurate detection range and prevent missed activations during laboratory use.
Charge the battery monthly even during periods of non-use to maintain optimal battery performance and longevity.
Why: Regular charging prevents deep discharge conditions that can reduce battery capacity and operational reliability.
Setup Guide
What’s in the Box
- Intelligent Induction Sterilizer main unit
- Type-C USB charging cable
- User manual and setup instructions
- Reservoir filling funnel (typical)
- Quick start guide (typical)
Compliance
Warranty & ConductCare
ConductScience provides a standard one-year manufacturer warranty covering defects in materials and workmanship, with technical support for setup and operational questions.
What types of disinfectants are compatible with the reservoir system?
The ABS+PC+PP shell construction is compatible with standard laboratory disinfectants including isopropyl alcohol, ethanol-based solutions, and quaternary ammonium compounds. Consult product datasheet for specific chemical compatibility requirements.
How long does the 1200mAh battery operate between charges?
Battery life depends on activation frequency and spray duration. With 2W power consumption, expect several days of typical laboratory use. Monitor battery indicator and recharge via Type-C USB as needed.
Can the detection range be adjusted for specific applications?
The 1-12cm detection range is factory-calibrated. Position the unit at appropriate height and angle to optimize activation zone for your specific laboratory workflow requirements.
What maintenance is required for the spray mechanism?
Regular cleaning of the spray nozzle prevents clogging from disinfectant residue. Empty and rinse the reservoir weekly or when changing disinfectant types to prevent contamination.
Is the unit suitable for continuous operation in active laboratories?
Yes, the device is designed for continuous infrared monitoring and automatic activation. The 100ml reservoir and 40-60ml/h spray rate provide adequate capacity for busy laboratory environments.
How does spray output compare to manual dispensers?
The controlled 40-60ml/h output provides consistent volume per activation, eliminating over-dispensing common with manual pumps while ensuring adequate surface coverage through automated timing.
Can multiple units be synchronized for large laboratory spaces?
Each unit operates independently with its own infrared sensor and control system. Multiple units can be positioned throughout the laboratory without interference between detection zones.
Have a question about this product?
Accessories
Enhance your setup with compatible accessories