Hotplate Magnetic Stirrer MYP Series
Compact hotplate magnetic stirrer with φ145mm aluminum work plate, digital display, and 0-1500 rpm speed range for heating and mixing laboratory solutions up to 5L.
| Automation Level | manual |
| MYP11-2A | SH05-3G |
| X85-2 | X85-2S |
| Work Plate Size | φ145mm |
| φ175mm | φ145mm |
| Work Plate Material | Aluminum alloy |
The Hotplate Magnetic Stirrer MYP Series is a compact benchtop instrument designed for simultaneous heating and stirring of laboratory solutions. Featuring a φ145mm aluminum alloy work plate and brushless DC motor with 15W output, this unit provides precise temperature and speed control for volumes up to 5L. The digital display shows real-time speed, temperature, and time parameters, while button controls enable straightforward operation in laboratory workflows.
The instrument operates across a speed range of 0-1500 rpm with brushless motor technology ensuring reliable, long-term operation. The aluminum alloy work plate provides efficient heat distribution and chemical resistance for diverse laboratory applications. Digital parameter monitoring supports reproducible experimental conditions and protocol standardization.
How It Works
The hotplate magnetic stirrer operates on electromagnetic induction principles for both heating and stirring functions. The heating element beneath the aluminum alloy work plate provides controlled thermal energy transfer to vessels, while the integrated magnetic field generator creates a rotating magnetic field. A magnetic stir bar placed in the solution couples with this field, rotating to provide continuous agitation.
The brushless DC motor system generates precise magnetic field rotation across the 0-1500 rpm range, ensuring consistent stirring action without mechanical wear. Temperature control is achieved through resistance heating elements with digital feedback monitoring. The aluminum alloy work plate distributes heat evenly while providing chemical resistance and thermal stability.
Digital sensors monitor speed, temperature, and elapsed time, displaying real-time values for experimental documentation. Button controls allow independent adjustment of heating and stirring parameters to match specific protocol requirements.
Features & Benefits
Automation Level
- manual
MYP11-2A
- SH05-3G
X85-2
- X85-2S
Work Plate Size
- φ145mm
φ175mm
- φ145mm
Work Plate Material
- Aluminum alloy
Stainless steel
- Aluminum alloy
Max. Stirring Capacity
- 5L
10L
- 5L
Motor Type
- Brushless DC motor
Motor Output
- 15W
Speed Range
- 0~1500rpm
Digital Display
- Speed, temperature, time
Control
- Button
knob-button
- Button
Brand
- ConductScience
Research Domain
- Analytical Chemistry
- Cell Biology
- Environmental Monitoring
- Food Science
- Materials Science
- Microbiology
- Pharmaceutical QC
Weight
- 29.98 kg
Dimensions
- L: 42.0 mm
- W: 43.6 mm
- H: 38.0 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Motor Type | Brushless DC motor with 15W output | Entry-level models often use brushed motors with lower power output | Brushless design eliminates maintenance requirements and provides more consistent long-term performance |
| Work Plate Material | Aluminum alloy construction | Ceramic or basic aluminum plates are common in budget models | Aluminum alloy provides superior heat distribution and chemical resistance for demanding applications |
| Digital Display | Shows speed, temperature, and time simultaneously | Basic models may show limited parameters or use analog displays | Comprehensive parameter monitoring enables better experimental documentation and reproducibility |
| Speed Range | 0-1500 rpm continuous range | Lower-end units typically offer reduced speed ranges | Extended speed range accommodates both gentle mixing and vigorous agitation requirements |
| Stirring Capacity | 5L maximum volume | Compact units often limit capacity to 1-3L | Higher capacity supports larger batch preparations and diverse vessel sizes |
The MYP Series combines brushless motor reliability with comprehensive digital monitoring in a space-efficient design. The aluminum alloy work plate and 5L capacity provide versatility for routine laboratory heating and mixing applications.
Practical Tips
Verify temperature accuracy periodically using a calibrated thermometer in water at multiple setpoints.
Why: Temperature calibration ensures accurate heating for temperature-sensitive reactions and procedures.
Clean the work plate surface regularly with appropriate solvents to prevent chemical buildup and maintain heat transfer efficiency.
Why: Clean surfaces ensure optimal thermal contact and prevent contamination between samples.
Start stirring before heating to establish circulation patterns and prevent hot spots in the solution.
Why: Pre-established mixing prevents thermal gradients and ensures uniform temperature distribution.
If stirring becomes erratic, check for magnetic interference from nearby equipment or oversized stir bars.
Why: Magnetic field disruption can cause irregular stirring that affects mixing efficiency and reproducibility.
Record all parameter settings and monitor displayed values throughout procedures for experimental documentation.
Why: Documented parameters enable method validation and troubleshooting of variable results.
Use appropriate vessel supports for tall containers to prevent tipping during vigorous stirring.
Why: Proper vessel stabilization prevents spills and potential chemical exposure hazards.
Allow the work plate to cool completely between applications involving different chemicals to prevent cross-contamination.
Why: Thermal cycling helps remove residual chemicals and maintains analytical integrity between samples.
Setup Guide
What’s in the Box
- Hotplate magnetic stirrer main unit
- Power cord (typical)
- User manual with operating instructions (typical)
- Warranty documentation (typical)
Warranty
ConductScience provides a standard one-year manufacturer warranty covering defects in materials and workmanship, with technical support available for troubleshooting and operational guidance.
Compliance
References
Background reading relevant to this product:
What is the temperature range and accuracy of the heating function?
Consult the product datasheet for specific temperature range and accuracy specifications, as these parameters vary by model configuration.
What size magnetic stir bars are compatible with the 5L capacity specification?
The 5L capacity accommodates standard laboratory stir bars ranging from 25-50mm length, depending on vessel geometry and solution viscosity.
Can the unit maintain stable temperature during continuous stirring?
Yes, the aluminum alloy work plate and digital control system are designed to maintain temperature stability during simultaneous heating and stirring operations.
How does the brushless motor design affect maintenance requirements?
Brushless DC motors require minimal maintenance compared to brushed motors, eliminating brush replacement while providing consistent performance over extended use.
What is the maximum viscosity that can be effectively stirred at 1500 rpm?
Effective stirring depends on solution properties and stir bar size; consult product specifications for viscosity limitations at maximum speed.
Is the digital display readable in typical laboratory lighting conditions?
The digital display is designed for laboratory use and shows speed, temperature, and time parameters clearly under standard ambient lighting.
What type of vessels are compatible with the φ145mm work plate?
The work plate accommodates standard laboratory glassware including beakers, flasks, and custom vessels with flat bottoms up to the plate diameter.