Large Capacity Vertical Type Shaking Incubator
High-capacity vertical shaking incubator with multiple flask clamp configurations and wide temperature range
The Large Capacity Vertical Type Shaking Incubator is available in multiple configurations for microbiology, cell culture, and biochemistry applications. The standard configuration operates at 110V 60Hz with a temperature range of 4–65°C and includes 25 × 150 mL flask clamps. The double-layer configuration includes 24 × 250 mL flask clamps. Flask clamp options are available for 50 mL, 100 mL, 150 mL, 250 mL, 500 mL, 1 L, 2 L, 3 L, and 5 L capacities.
The chamber door features a rubber gasket seal, and the unit uses a closed-system design with internal fans for forced air convection to ensure uniform temperature distribution. The interior shaking platform provides orbital motion independently of the incubator housing.
How It Works
The shaking incubator operates through integrated thermal and mechanical control systems that maintain optimal conditions for biological processes. Temperature regulation utilizes PID microcomputer control with forced convection circulation, where heated air is distributed uniformly throughout the 610L chamber via internal fans. The system continuously monitors temperature through integrated sensors, making real-time adjustments to maintain the setpoint within ±0.1°C accuracy.
The rotary shaking mechanism employs a balanced platform system that provides consistent orbital motion across the entire chamber floor. The motor-driven platform oscillates in a circular pattern with user-adjustable amplitude (26mm diameter) and speed (30-300 rpm), ensuring uniform agitation of samples regardless of chamber position. This dual-action environment promotes gas exchange, nutrient distribution, and heat transfer essential for optimal biological culture conditions.
The LCD touch screen interface integrates both temperature and shaking control parameters, allowing researchers to program complex protocols with timing functions up to 999 minutes or hours. The forced convection system maintains temperature uniformity within ±1°C throughout the chamber volume, while speed accuracy of ±1 rpm ensures reproducible agitation conditions across experimental replicates.
Features & Benefits
Configuration
- Standard
- Double Door / Double Layer (A)
- Double Door / Double Layer (B)
Weight
- 550.0 kg
Dimensions
- L: 99.0 mm
- W: 119.8 mm
- H: 52.0 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Chamber Capacity | 610L large capacity chamber | Entry-level models typically offer 100-300L capacity | Enables simultaneous processing of larger sample batches and multiple experimental conditions, increasing laboratory productivity. |
| Temperature Accuracy | ±0.1°C precision control | Standard units often provide ±0.5-1.0°C accuracy | Critical for temperature-sensitive cultures and applications requiring tight thermal regulation for reproducible results. |
| Shaking Speed Range | 30-300 rpm with ±1 rpm accuracy | Basic models may have limited speed ranges or lower precision | Accommodates diverse culture types from gentle cell lines to vigorous bacterial growth requiring specific agitation rates. |
| Control Interface | LCD touch screen with PID microcomputer control | Entry-level units may use basic digital displays or analog controls | Enables precise programming of complex protocols and real-time parameter monitoring for advanced experimental designs. |
| Temperature Uniformity | ±1°C throughout chamber at 37°C with forced convection | Basic models may have larger temperature gradients | Ensures consistent culture conditions across all sample positions, eliminating position-dependent experimental variability. |
This large capacity shaking incubator offers precise environmental control with 610L chamber capacity, ±0.1°C temperature accuracy, and programmable shaking from 30-300 rpm. The combination of high capacity and precision control makes it suitable for laboratories requiring large-scale culture processing with research-grade environmental stability.
Practical Tips
Verify temperature accuracy at multiple setpoints across the operating range using certified thermometers placed in different chamber locations.
Why: Ensures uniform temperature control throughout the large chamber volume and validates accuracy across the full temperature range.
Clean shaking platform and chamber surfaces weekly with appropriate disinfectants, paying attention to areas around the platform bearings.
Why: Prevents contamination buildup and maintains smooth mechanical operation of the shaking mechanism.
Distribute sample vessels evenly across the platform surface and secure with appropriate clamps to prevent movement during operation.
Why: Maintains platform balance and prevents vessel damage while ensuring consistent agitation for all samples.
Allow unit to equilibrate for at least 30 minutes at target temperature before adding samples for critical applications.
Why: Ensures stable thermal conditions and prevents temperature fluctuations that could affect sensitive biological processes.
If temperature uniformity issues arise, check that chamber vents are unobstructed and forced convection fans are operating properly.
Why: Proper air circulation is essential for maintaining the specified ±1°C temperature uniformity across the large chamber volume.
Ensure adequate clearance around the unit for ventilation and heat dissipation, especially when operating at elevated temperatures.
Why: Prevents overheating of internal components and maintains safe laboratory working conditions around the equipment.
Document shaking speed and temperature parameters for each experiment, as these significantly affect culture growth and reproducibility.
Why: Environmental conditions directly impact biological processes and must be recorded for experimental reproducibility and troubleshooting.
Setup Guide
What’s in the Box
- Large capacity shaking incubator main unit
- Shaking platform assembly
- Power cord
- User manual and operation guide
- Calibration certificate (typical)
- Flask clamps and holders (typical)
Warranty
ConductScience provides standard one-year manufacturer warranty covering parts and labor for defects in materials and workmanship. Technical support includes installation guidance, operation training, and calibration services.
Compliance
What is the maximum sample volume this incubator can accommodate?
The 610L chamber capacity can accommodate multiple large flasks or numerous smaller vessels depending on configuration. Exact capacity depends on vessel size and arrangement on the shaking platform.
How accurate is the temperature control for cell culture applications?
Temperature control maintains ±0.1°C accuracy with uniformity within ±1°C at 37°C throughout the chamber volume, suitable for mammalian cell culture requirements.
Can the shaking speed be adjusted during operation without stopping?
Yes, the LCD touch screen interface allows real-time adjustment of both temperature and shaking parameters without interrupting ongoing protocols.
What type of vessels can be used with the shaking platform?
The platform accommodates various flask sizes and container types with appropriate clamps and holders. Consult product datasheet for specific vessel compatibility and weight limits.
How often does this unit require calibration?
Calibration frequency depends on usage intensity and accuracy requirements. For critical applications, quarterly temperature verification is recommended using certified reference thermometers.
Is the unit suitable for anaerobic culture conditions?
While the unit provides controlled temperature and agitation, additional gas control systems would be required for strict anaerobic conditions. Consult product specifications for gas inlet options.
What is the noise level during shaking operation?
Operational noise levels vary with shaking speed. Consult product datasheet for specific decibel ratings at various rpm settings for laboratory planning purposes.
What flask clamp sizes are available for different sample volumes?
The vertical shaking incubator offers flask clamps in multiple sizes to accommodate various sample volumes: 50ml, 100ml, 150ml, 250ml, 500ml, 1L, 2L, 3L, and 5L. The standard configuration includes either 25pcs of 150ml clamps or 24pcs of 250ml clamps depending on the model. Custom clamp configurations may be available upon request.
What are the space requirements for installation?
The vertical design allows for efficient use of laboratory space while accommodating multiple samples. The unit is designed to fit in standard laboratory environments. For specific dimensional requirements and space planning, please consult the technical specifications or contact our support team for detailed measurements.
Does the shaking incubator have a rubber gasket sealing the chamber door?
Yes. The chamber door is fitted with a rubber gasket that provides a secure seal, helping maintain consistent internal conditions during incubation.
Does the incubator include a HEPA filter or gas exhaust system?
No. This is a closed-system incubator without a HEPA filter. It uses internal fans for forced air convection to ensure uniform temperature distribution throughout the chamber. If your application requires gas venting, please contact us to discuss compatible options.
Is this incubator available in 110V for use in the United States?
Yes. The standard configuration operates at 110V 60Hz, making it suitable for standard US laboratory power outlets.
What flask clamp sizes are available for the shaking incubator?
Flask clamps are available for 50 mL, 100 mL, 150 mL, 250 mL, 500 mL, 1 L, 2 L, 3 L, and 5 L flasks. Please specify your required flask size when ordering.
Does the entire incubator cabinet shake during operation?
No. The interior shaking platform moves independently inside the cabinet — the external incubator body remains stationary. This keeps the footprint stable during operation.
Have a question about this product?
Accessories
Enhance your setup with compatible accessories