Pathology Grossing Station Series (RD-907)
RD-907 pathology grossing station family available in touchscreen, standard, and simple configurations for specimen trimming, rinsing, drainage, and gross examination workflows.
| Material | Stainless steel 304 |
| Brand | ConductScience |
RD-907 Grossing Station is the ConductScience family page for three related pathology grossing workstation configurations built around the same stainless steel specimen-processing platform. The matched supplier sources separate the family into touchscreen, standard, and simple versions, each intended for rinsing, drainage, illumination, and organized grossing workflow in pathology settings.
Select the model that fits your workflow and budget. The touchscreen model adds an integrated control interface, the standard configuration emphasizes washdown and disinfection features, and the simple configuration provides a cleaner lower-complexity workstation while retaining the core stainless steel grossing format.
Available Configurations
- RD-907S-M Touchscreen - touchscreen control panel, safety splash door, built-in exhaust integration, and height-adjustable grossing layout
- RD-907S Standard - LED lighting, UV disinfection, automatic table washing, magnetic tool tray, and pathology workbench layout
- RD-907S-N Simple - adjustable rack system, integrated surgical lighting, retractable hand spray, and dual-drain work surface
Shared Platform Benefits
- 304 stainless steel construction for cleanability and corrosion resistance
- Integrated sink and drainage workflow for specimen grossing and washdown tasks
- Work-surface lighting and accessory support for organized pathology operation
- Model-specific feature tiers for touchscreen, standard, or simplified setups
How It Works
Pathology grossing involves systematic macroscopic examination of tissue specimens before histological processing. The grossing table provides a controlled workspace where specimens are examined under optimal lighting conditions, measured, photographed, and sectioned according to established protocols. The stainless steel surface ensures easy decontamination between specimens while maintaining specimen integrity.
The dual faucet system enables continuous water flow for specimen hydration and immediate cleaning of instruments and work surfaces. UV disinfection capability provides germicidal treatment of the work area between cases, particularly important when processing specimens with potential infectious agents. The automated table washing system ensures thorough decontamination following established laboratory safety protocols.
Adjustable table height accommodates proper ergonomics during extended grossing sessions, reducing fatigue and improving precision during specimen sectioning. The magnetic tool tray keeps cutting instruments organized and readily accessible, while movable cutting boards provide dedicated surfaces for different specimen types or cases.
Features & Benefits
Model
- RD-907S Standard
- RD-907S-M Touchscreen
- RD-907S-N Simple
Research Domain
- Cancer Research
- Clinical Diagnostics
- Histopathology
- Pharmaceutical QC
- Toxicology
Material
- Stainless steel 304
Brand
- ConductScience
Weight
- 36.71 kg
Dimensions
- L: 46.5 mm
- W: 44.0 mm
- H: 35.5 mm
Comparison Guide
| Feature | This Product | Typical Alternative | Advantage |
|---|---|---|---|
| Work Surface Dimensions | 1500mm × 800mm stainless steel 304 | Standard models often provide smaller work surfaces with basic stainless steel construction | Larger workspace accommodates multiple specimens and instruments simultaneously during complex grossing procedures. |
| Height Adjustability | 800-1000mm adjustable range | Fixed height tables or limited adjustment ranges | Broad adjustment range accommodates diverse user heights and reduces ergonomic strain during extended use. |
| Integrated Systems | Dual faucets, LED lighting, UV disinfection, automated washing | Basic models require separate UV lamps, external lighting, and manual cleaning | Integrated design reduces equipment footprint and ensures consistent decontamination protocols. |
| Power Requirements | 220V/50Hz, 560W with leakage protection | Lower power consumption but limited integrated features | Higher power capacity supports multiple simultaneous systems while maintaining electrical safety standards. |
| Cutting Board Organization | 3 movable cutting boards with magnetic tool tray | Fixed cutting surfaces or minimal organization features | Multiple boards prevent cross-contamination while magnetic tray keeps instruments immediately accessible. |
| Cleaning Systems | High-pressure shower plus automated table washing | Manual cleaning or basic water connections | Dual cleaning systems ensure thorough decontamination between cases without workflow interruption. |
The RD-907S-C provides comprehensive integrated functionality including automated cleaning, UV disinfection, and ergonomic adjustability in a single unit. The 560W power capacity and stainless steel 304 construction support demanding laboratory environments requiring consistent decontamination and workflow efficiency.
Practical Tips
Verify height adjustment mechanism operates smoothly through full 800-1000mm range during monthly equipment checks.
Why: Proper height adjustment prevents ergonomic strain and maintains precision during extended grossing sessions.
Replace UV disinfection lamps according to manufacturer schedule and monitor output with UV meter quarterly.
Why: UV lamp degradation over time reduces disinfection efficacy and compromises contamination prevention protocols.
Use dedicated cutting boards for different specimen types (fresh, fixed, suspected infectious) to prevent cross-contamination.
Why: Specimen-specific boards maintain sample integrity and reduce risk of diagnostic artifacts from contamination.
Run automated washing cycle between high-risk specimens and allow complete drying before next case.
Why: Thorough decontamination prevents carryover of potentially infectious agents or tissue fragments.
Ensure electrical leakage protector functions properly through monthly testing of ground fault protection.
Why: Water and electrical systems require proper protection to prevent shock hazards in laboratory environments.
If LED lighting appears dim or uneven, clean lens covers and inspect for moisture infiltration in electrical components.
Why: Optimal illumination is critical for accurate gross examination and identification of subtle pathological features.
Position the unit to minimize shadows on work surface and ensure uniform LED illumination for specimen photography.
Why: Consistent lighting conditions improve image quality for gross documentation and educational purposes.
Descale water lines and faucets monthly to prevent mineral buildup that could affect water flow during specimen processing.
Why: Consistent water flow is essential for specimen hydration and immediate cleaning of cutting instruments.
Setup Guide
What’s in the Box
- Stainless steel grossing table frame and work surface
- Dual water faucets with mounting hardware
- LED lighting system with controls
- UV disinfection lamp assembly
- High-pressure shower attachment
- Automated table washing system
- Three movable cutting boards
- Magnetic tool organization tray
- Electrical components with leakage protector
- Installation hardware and mounting brackets
- User manual and safety documentation (typical)
- Warranty documentation (typical)
Warranty
ConductScience provides a standard one-year manufacturer warranty covering materials and workmanship defects, with technical support for installation, operation, and maintenance procedures specific to pathology laboratory environments.
Compliance
References
Background reading relevant to this product:
What are the electrical requirements for installation?
The unit requires 220V/50Hz electrical supply with 560W power consumption and includes integrated electrical leakage protection for laboratory safety.
How does the height adjustment mechanism work?
The table height adjusts mechanically within the 800-1000mm range to accommodate different user ergonomic requirements during grossing procedures.
What cleaning protocols are supported by the automated washing system?
The automated table washing system provides thorough decontamination of the stainless steel work surface following laboratory safety protocols between specimen cases.
Can the UV disinfection system be used during specimen processing?
UV disinfection should be used between cases or during downtime, not during active specimen handling, to prevent UV exposure to personnel and specimens.
What type of cutting boards are included and can they be sterilized?
Three movable cutting boards are included as standard equipment; specific material composition and sterilization compatibility should be confirmed in the technical specifications.
How does this compare to basic grossing benches?
This unit provides integrated systems including dual faucets, automated cleaning, UV disinfection, and adjustable height versus basic static benches requiring separate equipment.
What maintenance is required for the automated systems?
Regular maintenance includes cleaning of water lines, LED lamp inspection, UV lamp replacement per manufacturer schedule, and verification of electrical protection systems.
Is the unit suitable for high-volume pathology laboratories?
The 1500mm × 800mm work surface and automated cleaning features support efficient workflow in laboratories processing multiple specimens daily.